WEINTEK-logo

WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller

WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-product

Zofotokozera

Malangizo oyika

Kusintha kwa HMI: 

Parameters Analimbikitsa Zosankha Zolemba
Mtundu wa PLC KEYENCE KV-8000/KV-X (Symbolic) (Ethernet)
PLC I/F Efaneti
Port no. 8500
Mtundu wa chipangizo KV8000 KV8000 / KVX
Simulator pa intaneti Inde Multi-HMI kugwirizana Inde

Tumizani kunja Tags:

Software KV STUDIO creates tag:

  1. Variable -> Cerected tag on Global or Local table.WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig1
  2. Support Sturcutre address. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig2
  3. Tumizani kunja tag: File -> Output CSV/TXT file -> Variable information WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig3

Tengani Tags:

  1. In EasyBuilder Pro -> System Parameter Settings -> New Driver (KV-8000) -> Import Tags. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig4
  2. Select the .txt file kuitanitsa. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig5
  3. Import some or all of the tags WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig6
  4. Sankhani a tag you want to import in Tag Manager, press OK. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig7
  5. Zachokera kunja tag zambiri bwino. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig8

Mtundu Wothandizira Chipangizo

Mtundu wa data Mtundu wa data wa EasyBuilder Memo
BOOL pang'ono
INT 16-bit BCD, Hex, Binary, Signed 16-bit
UINT 16-bit BCD, Hex, Binary, Unsigned 16-bit
DINT 32-bit BCD, Hex, Binary, Signed 32-bit
UDINT 32-bit BCD, Hex, Binary, Unsigned 32-bit
ZOONA 32-bit Float 32-bit
LREAL 64-bit Float 64-bit *Zindikirani1
STRING Mndandanda wamawu wolowetsa ndikuwonetsa ASCII *Zindikirani2
 

Gulu

BOOL, INT, UINT, DINT,UDINT, REAL,

LREAL, Structure

*Zindikirani3

 

Mapangidwe

BOOL, INT, UINT, DINT,UDINT, REAL, LREAL, STRING

Gulu

  • Note1: EBPro V6.03.02 kapena mtsogolomo imathandizira mtundu wa data wa 64 bits (cMT Series yokha), koma chonde dziwani kuti malire a ma adilesi ndi ma 48 bits pakupitilira.
  • Chidziwitso 2: String In EasyBuilder Pro, only even addresses can be selected, and support string length up to 2000.WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig9
  • Chidziwitso 3: Support 1~3D array, 4D arrays and above cannot be imported.

Chithunzi cha Wiring

Chingwe cha Ethernet:

WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig10

FAQs

How do I connect multiple HMIs?

You can connect multiple HMIs using the on-line simulator option in the HMI settings.

What is the maximum string length supported for STRING data type?

In EasyBuilder Pro, only even addresses can be selected, and it supports string length up to 2000.

Zolemba / Zothandizira

WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller [pdf] Buku Logwiritsa Ntchito
KEYENCE KV-8000-KV-X, KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller, Symbolic Ethernet Programmable Logic Controller, Ethernet Programmable Logic Controller, Programmable Logic Controller, Logic Controller

Maumboni

Siyani ndemanga

Imelo yanu sisindikizidwa. Minda yofunikira yalembedwa *