Anern FGI-DU4200

Anern FGI-DU4200 Dual Voltage Hybrid Solar Inverter User Manual

Model: FGI-DU4200

Mtundu: Anern

1. Mawu Oyamba

This manual provides essential information for the safe and efficient operation of your Anern FGI-DU4200 Dual Voltage Hybrid Solar Inverter. Please read this manual thoroughly before installation and use, and retain it for future reference. This inverter is designed to provide reliable power for various applications, integrating solar charging, AC utility charging, and inverter output functions.

Anern FGI-DU4200 Dual Voltage Hybrid Solar Inverter front view

Chithunzi 1: Anern FGI-DU4200 Dual Voltage Hybrid Solar Inverter. This image shows the front panel of the inverter, featuring the display screen and control buttons.

2. Malangizo a Chitetezo

Please observe the following safety precautions to prevent injury and damage to the inverter or connected equipment:

  • Installation must be performed by qualified personnel in accordance with local electrical codes.
  • Ensure all wiring is correctly sized and properly connected.
  • Musamasule inverter. Palibe zida zomwe zingakonzedwe mkati mwake.
  • Sungani inverter kutali ndi zinthu zoyaka moto, chinyezi, ndi kuwala kwa dzuwa mwachindunji.
  • Onetsetsani kuti mpweya wokwanira wozungulira inverter kuti mupewe kutentha kwambiri.
  • Always disconnect all power sources (solar, battery, utility) before performing any maintenance or wiring.
  • Valani zida zoyenera zodzitetezera (PPE) pakukhazikitsa ndi kukonza.

3. Zamalonda Zathaview ndi Features

The Anern FGI-DU4200 is a versatile hybrid solar inverter designed for both on-grid and off-grid applications. It features automatic dual-voltage operation and a 120A MPPT solar charge controller.

Zofunika Kwambiri:

  • Automatic Dual-Voltage ntchito: Automatically recognizes 12VDC (2300W output) or 24VDC (4200W output) battery systems.
  • High-Efficiency Pure Sine Wave Output: Provides stable 220-230VAC ±5% output (50Hz) with 90% efficiency.
  • Integrated 120A MPPT Solar Charge Controller: Maximizes solar power harvesting.
  • Njira Zolipirira Zambiri: Solar, Solar and Utility, Solar Priority.
  • Zotulutsa Zingapo: Solar Priority, Utility Priority, SBU (Solar-Battery-Utility) Mode.
  • Seamless Transfer: Grid/generator transfer time less than 20ms for critical loads.
  • Chitetezo chokwanira: Overload, over-temperature, and short-circuit protection.
  • Kugwirizana kwa Battery: Supports 12V/24V Lithium, Lead-Acid, and Gel batteries.
  • Cold Start Capability: Ensures operation in extreme conditions.
  • Wi-Fi Monitoring: Allows system operation control via mobile phone (requires optional Wi-Fi module).
Anern FGI-DU4200 Inverter Features Overview

Chithunzi 2: Zathaview of key features including frequency range, waveform, charging currents, battery voltage, and protection mechanisms.

Anern FGI-DU4200 Dual Voltagndi Kukhoza

Chithunzi 3: Illustration of the inverter's dual voltage capability, supporting 4.2KW at 24V and 2.3KW at 12V battery systems.

4. Kukhazikitsa ndi Kuyika

4.1 Kutsegula ndi Kuyendera

Upon receiving the inverter, carefully unpack it and inspect for any shipping damage. Ensure all components listed in the packing list are present. If any damage or missing parts are found, contact your dealer immediately.

4.2 Kuyika Inverter

Mount the inverter vertically on a sturdy wall or surface. Ensure there is sufficient clearance around the unit for proper ventilation (at least 20 cm on all sides). Avoid mounting in direct sunlight, near heat sources, or in areas with excessive dust or moisture.

4.3 Kulumikizana kwa Wiring

All wiring must comply with local electrical codes. Use appropriate wire gauges for all connections to prevent overheating and ensure efficient power transfer.

4.3.1 Kulumikizana kwa Battery

The inverter supports both 12VDC and 24VDC battery systems. The inverter automatically detects the battery voltage. Ensure correct polarity when connecting batteries. For 12V systems, batteries are typically connected in parallel. For 24V systems, batteries are typically connected in series.

Battery Connection Diagram for 12V Parallel and 24V Series

Chithunzi 4: Wiring diagram illustrating parallel connection for 12V battery systems (2300W output) and series connection for 24V battery systems (4200W output).

Compatible Battery Types for Anern FGI-DU4200 Inverter

Chithunzi 5: The inverter is compatible with various battery types, including Gel, AGM, Flooded (FLD), Lithium (LI), and Sealed Lead-Acid (SLD) batteries.

4.3.2 Kulumikiza kwa Ma Solar Panel

Connect your solar panels to the designated PV input terminals. Ensure the open circuit voltage (Voc) of your solar array does not exceed the inverter's maximum PV input voltage (500Vdc). Observe correct polarity.

4.3.3 AC Input Connection (Utility/Generator)

Connect the AC utility grid or a compatible generator to the AC input terminals. The inverter supports 220-230VAC input. Ensure proper grounding.

4.3.4 AC Output Connection (Loads)

Connect your household or office loads to the AC output terminals. The inverter provides a pure sine wave output suitable for sensitive electronics. Do not exceed the rated output power of the inverter (2300W for 12VDC systems, 4200W for 24VDC systems).

Anern FGI-DU4200 System Diagram

Chithunzi 6: Comprehensive system diagram showing connections for solar panels, generator/utility, external battery packs, and various home appliances.

Anern FGI-DU4200 Inverter Outdoor Installation Example

Chithunzi 7: Example of an outdoor installation of the Anern FGI-DU4200 inverter, demonstrating its integration into a home solar power system.

5. Malangizo Ogwiritsira Ntchito

5.1 Kuyatsa/Kuzimitsa

After all connections are securely made, switch on the battery breaker first, then the solar array breaker, and finally the AC input breaker (if connected). Press the power button on the inverter to turn it on. To power off, reverse the sequence: turn off AC input, then solar, then battery, and finally the inverter power button.

5.2 LCD Display and Control Buttons

The inverter features an LCD display that shows real-time operating status, input/output voltages, battery status, and error codes. Use the control buttons (ESC, UP, DOWN, ENTER) to navigate through menus and adjust settings.

5.3 Njira Zopangira

The inverter offers four selectable charging modes:

  • Solar Priority: Solar power charges the battery first. If solar is insufficient, utility power supplements.
  • Utility Priority: Utility power charges the battery first. Solar power supplements if utility is unavailable.
  • Dzuwa Lokha: Only solar power charges the battery.
  • Solar and Utility: Both solar and utility power charge the battery simultaneously.

5.4 Mitundu Yotulutsa

The inverter offers three selectable output modes:

  • Utility Priority: Loads are primarily powered by utility. If utility fails, the inverter switches to battery power.
  • Solar Priority: Loads are primarily powered by solar. If solar is insufficient, battery power is used. If both are insufficient, utility power is used (if connected).
  • SBU (Solar-Battery-Utility) Mode: Loads are powered by solar first, then battery, and finally utility if both solar and battery are depleted or unavailable.

5.5 Wi-Fi Monitoring (Optional)

If equipped with the optional Wi-Fi module, the inverter can be monitored and controlled via a mobile application. Connect the Wi-Fi module to the designated port on the inverter and follow the instructions provided with the module for setup.

Wi-Fi Monitoring Setup for Anern FGI-DU4200 Inverter

Chithunzi 8: Diagram illustrating the connection of an optional Wi-Fi module for remote monitoring and control of the inverter system via a mobile application or web mawonekedwe.

6. Kusamalira

Kusamalira pafupipafupi kumatsimikizira kukhala ndi moyo wautali komanso kuchita bwino kwa inverter yanu.

  • Kuyeretsa: Periodically clean the inverter's exterior with a dry cloth. Ensure ventilation openings are free from dust and debris.
  • Kulumikizana: Annually check all electrical connections for tightness and corrosion. Re-tighten if necessary.
  • Kuyang'ana Battery: For lead-acid batteries, check electrolyte levels and terminal condition as per battery manufacturer guidelines.
  • Chilengedwe: Onetsetsani kuti malo ogwirira ntchito amakhala mkati mwa kutentha ndi chinyezi.

7. Mavuto

This section provides solutions to common issues. For problems not listed here, contact technical support.

VutoChifukwa ChothekaYankho
Inverter sikuyatsaPalibe kulumikizana kwa batri; Voliyumu ya batritage too low; Power button not pressed.Onani kugwirizana kwa batri ndi voltage; Charge battery; Press and hold power button.
Palibe zotulutsa za ACOverload; Short circuit; Battery low; Inverter fault.Reduce load; Check for short circuits; Charge battery; Restart inverter.
Kuchangitsa kwadzuwa sikukugwira ntchitoSolar panels disconnected; Insufficient sunlight; PV voltage too low/high; MPPT fault.Check PV connections; Ensure adequate sunlight; Verify PV voltage m'zigawo.
Khodi yolakwika yawonetsedwaSpecific fault detected by the inverter.Refer to the inverter's LCD display for the specific error code and consult the full manual (if available) or contact support for detailed interpretation and resolution.

8. Zofotokozera

ParameterMtengo
ChitsanzoFGI-DU4200
Rated Power (12VDC)2300W
Rated Power (24VDC)4200W
Battery Voltage12VDC / 24VDC (Auto-sensing)
Kutulutsa Voltage220-230VAC ±5% (50Hz)
WaveformMafuta Oyera
MPPT Solar Charge Controller Current120A
Max PV Array Open Circuit Voltage500vc ndi
AC adzapereke Current60A
Kuchita bwino90%
Nthawi Yosamutsa<20ms
Miyeso Yazinthu16.9 x 8.27 x 21.6 mainchesi
Kulemera kwa chinthu19.14 mapaundi
WopangaAnern

9. Chitsimikizo ndi Thandizo

Anern products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official Anern website. For technical support, troubleshooting assistance, or spare parts, please contact Anern customer service through their official channels. Please have your model number (FGI-DU4200) and purchase date ready when contacting support.

Zambiri zamalumikizidwe: Refer to your product packaging or the official Anern webwebusayiti kuti mudziwe zambiri zaposachedwa.

Zolemba Zofananira - FGI-DU4200

Preview ANERN FGI-S12000 Hybrid Solar Inverter User Manual
User manual for the ANERN FGI-S12000 Hybrid Solar Inverter. This guide details the installation, operation, safety, and specifications of the 12KW solar energy storage system, featuring MPPT charge control and UPS functionality.
Preview ANERN FGI-P6500 MPPT Solar Inverter User Manual
Explore the ANERN FGI-P6500 MPPT Solar Inverter with this comprehensive user manual. Learn about installation, operation, safety, and troubleshooting for your solar energy storage system.
Preview Anern MPPT Solar Inverter Product Manual: AN-FGI-AS12000 & AN-FGI-AS12000P
Comprehensive product manual for Anern AN-FGI-AS12000 and AN-FGI-AS12000P MPPT solar inverters. Covers installation, operation, safety, troubleshooting, and technical specifications for efficient solar energy management.
Preview Anern AN-FGI-AS7200/AS7200P MPPT Solar Inverter Product Manual | Installation & Operation Guide
Comprehensive product manual for Anern AN-FGI-AS7200 and AN-FGI-AS7200P MPPT Solar Inverters. Learn about installation, operation, features, safety, and technical specifications for hybrid solar energy systems.
Preview Buku la Anern Pure Sine Wave Hybrid Inverter: Kuyika, Chitetezo, ndi Maupangiri Ogwiritsa Ntchito
Bukuli la ogwiritsa ntchito limapereka malangizo achitetezo, kukhazikitsa, ndi magwiridwe antchito a Anern Pure Sine Wave Hybrid Inverter. Imakhala ndi chidziwitso chofunikira pazida, ma wiring, ndi kukhazikitsidwa kwamakina opangira mayankho odalirika amagetsi.
Preview Anern FGI-S4000 MPPT Solar Inverter User Manual
User manual for the Anern FGI-S4000 MPPT Solar Inverter, detailing installation, operation, safety, and troubleshooting for solar energy storage systems.