Testo 0564 5582 01

Testo 558s AC Manifold Gauge Set User Manual

Chitsanzo: 0564 5582 01

Mawu Oyamba

The Testo 558s Manifold Gauge is a state-of-art instrument designed for precise measurement and analysis of temperature and pressure in air conditioning, refrigeration, and heat pump systems. Featuring a 4-way valve block and an intuitive touchscreen, it provides a dynamic view of trending data, simplifying configuration, control, and documentation. This manual provides essential information for the safe and effective operation of your Testo 558s.

Zamkatimu Phukusi

Testo 558s AC Manifold Gauge Set with accessories

This image displays the complete Testo 558s AC Manifold Gauge Set, including the main manifold unit, two pipe-clamp thermometers, a vacuum probe, and a sturdy hard case for transport and storage.

Your Testo 558s AC Manifold Gauge Set package should contain the following items:

Zofunika Kwambiri

Component Yathaview

Labeled components of Testo 558s manifold gauge

This image highlights key components of the Testo 558s manifold. These include the Mini USB Port for firmware updates, the Touch Display for instrument status, Hose Brackets for refrigerant hoses, a Sight Glass for refrigerant flow, Valve Positioners for easy positioning, Connections (3 x 7/16" UNF + 1 x 5/8'' UNF) for low/high pressure, and a Mini-DIN Socket for NTC temperature probes.

Maluso apamwamba

Testo 558s advanced features diagram

This diagram illustrates several advanced features: a vacuum sensor for precise data, a 4-way valve for efficient diagnostics, enhanced data collection, touchscreen and remote operation, IP54 housing for protection, and suitability for A1 and A2L refrigerants.

Testo 558s automated and networked system

This image demonstrates the fully automated and networked capabilities of the Testo 558s system. It shows automatic calculation of target superheat and subcooling, logging of electrical parameters, temperature compensation, fully automatic charging with auto-stop function, and fully automatic evacuation with auto-stop functions and self-starting vacuum hold test.

Mfundo Zaukadaulo

KufotokozeraMtengo
Mitundu Yoyezera Kutentha-58.0 ° mpaka 302.0 °F / -50 mpaka +150 °C
Kulondola kwa Kutentha±0.9 °F / ±0.5 °C
Pressure Measuring Range-14.7 to 870 psi / -1 to 60 bar
Kulondola kwa Pressure±0.25 % Fs
Kugwirizana kwa Probe3 x 7/16" – UNF + 1 x 5/8'' – UNF
Pressure Overload Relay940 psi / 65 bala
Moyo wa Battery≤ 70 h with backlighting and Bluetooth®
Mtundu WabatiriBuilt-in rechargeable battery: LI battery 18650; 3x AA; Replaceable battery: 3 alkaline batteries AA
Miyeso Yazinthu9 x 4.4 x 2.8 mainchesi
Kulemera kwa chinthu3.2 mapaundi
ZakuthupiGalasi, Chitsulo chosapanga dzimbiri

Khazikitsa

Before first use, ensure all components are present and undamaged. Charge the internal battery or insert fresh AA alkaline batteries.

  1. Yatsani: Press and hold the power button on the Testo 558s unit until the display illuminates.
  2. Kuyika Battery: If using AA batteries, open the battery compartment on the rear of the unit and insert 3 AA batteries, observing polarity. For the rechargeable battery, connect the USB-C cable to the port and a power source.
  3. Kugwirizana kwa Probe: Connect the Testo 115i pipe-clamp thermometers and the Testo 552i vacuum probe to the appropriate ports on the manifold. Ensure connections are secure.
  4. Kulumikizana ndi Pulogalamu (Mwasankha): Download the Testo Smart App from your device's app store. Enable Bluetooth on your mobile device and open the app. Follow the in-app instructions to pair with your Testo 558s unit. This allows for remote operation and enhanced data visualization.

Ntchito

The Testo 558s offers flexible operation via its touchscreen, physical buttons, or the Testo Smart App.

  1. Kusankha Muyezo: Use the touchscreen or navigation buttons to select the desired measurement menu (e.g., Superheat/Subcooling, Evacuation, Pressure Test).
  2. Kugwirizana Hoses: Attach appropriate refrigerant hoses to the manifold's connections (3 x 7/16" UNF + 1 x 5/8'' UNF) and to the system being measured. Ensure all connections are tight to prevent leaks.
  3. Performing Measurements: Follow the on-screen prompts for the selected measurement mode. The display will show real-time data, including pressure, temperature, and calculated values. Graphical data trends over 30 minutes are available for dynamic analysis.
  4. Using the Testo Smart App: For advanced functionality, use the Testo Smart App. The app provides a comprehensive interface for controlling the manifold, viewing measurements, and generating reports.
  5. Refrigerant Selection: The manifold has over 90 refrigerants stored. Select the correct refrigerant type for accurate calculations. The device supports A2L and A3 refrigerants.

Kusamalira

Proper maintenance ensures the longevity and accuracy of your Testo 558s.

Kusaka zolakwika

VutoChifukwa ChothekaYankho
Chigawo sichimayatsa.Low or depleted battery; Incorrect battery installation.Charge the internal battery or replace AA batteries. Ensure correct polarity.
Kuwerenga molakwika.Probes not properly connected; Incorrect refrigerant selected; Unit requires calibration.Check probe connections. Verify refrigerant type. Consider professional calibration.
Mavuto okhudzana ndi Bluetooth.Bluetooth disabled on device; Unit too far from mobile device; App not updated.Ensure Bluetooth is enabled. Move closer to the unit. Update Testo Smart App. Restart both devices.
Display unresponsive.Software glitch; Extreme temperature conditions.Perform a soft reset (refer to specific device instructions if available). Operate within specified temperature range.

Chitsimikizo ndi Thandizo

The Testo 558s AC Manifold Gauge Set is manufactured by Testo SE & Co. KGaA. For specific warranty information, technical support, or service inquiries, please contact Testo customer service or visit their official webmalo. Sungani umboni wanu wogula kuti mutenge chitsimikizo.

Wopanga: Testo SE & Co. KGaA

Webtsamba: www.testo.com (Please refer to the official Testo website for the most current contact and support information.)

Zolemba Zofananira - 0564 5582 01

Preview Testo Smart Probes Instruction Manual: Guide to Measurement Instruments
Comprehensive instruction manual for Testo Smart Probes, detailing setup, operation, app usage, technical specifications, and maintenance for various measurement instruments like testo 405i, 410i, 510i, 549i, 552i, 605i, 805i, 905i, 115i, and 915i.
Preview Testo Smart Probes User Manual and Technical Data
Comprehensive guide to Testo Smart Probes, detailing setup, app usage, measurement applications, troubleshooting, and technical specifications for models like testo 115i, 405i, 510i, and more.
Preview Testo 552i Smart Vacuum Probe: Quick Start Guide and Specifications
Comprehensive guide to the Testo 552i smart vacuum probe, including product features, technical specifications, operating instructions, and international certifications. Learn about its Bluetooth connectivity, measurement capabilities, and app integration for HVAC and refrigeration applications.
Preview Testo 558s Digital Manifold: Product Overview ndi Mafotokozedwe
Comprehensive overview of the Testo 558s digital manifold, detailing its features, technical specifications, and regulatory compliance for HVAC and refrigeration professionals.
Preview Dongosolo Loyezera Tinthu Tating'onoting'ono ta Testo 380: Buku Lothandiza Kwambiri
Dziwani Testo 380, njira yatsopano yoyezera tinthu tating'onoting'ono mumakina olimba amafuta, mafuta, ndi gasi. Bukuli limafotokoza bwino mawonekedwe ake, tsatanetsatane waukadaulo, ndi zowonjezera zake, ndikugogomezera kusavuta kugwiritsa ntchito komanso deta yolondola nthawi yeniyeni.
Preview Testo Smart Probes User Manual: Features, Specifications, and Operation
Comprehensive user manual for Testo Smart Probes, detailing features, technical specifications, safety guidelines, and operation principles for models like testo 405i, 410i, 510i, 549i, 605i, 115i, 905i, and 805i. Includes product overview, technical data, and approval information.