Mawu Oyamba
This manual provides essential information for the safe and efficient operation of your Daikin ATMOSPHERA 18K BTU Heat Pump Hi-Wall Fan Coil System. This system comprises an RXM18WVJU9 outdoor unit and an FTXM18WVJU9 indoor unit. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper use and to prevent damage or injury.

Chithunzi 1: Daikin ATMOSPHERA 18K BTU Heat Pump Hi-Wall Fan Coil System. The image displays the white, rectangular indoor unit positioned above the larger, off-white outdoor unit with a prominent fan grille.
Chitetezo
- Installation must be performed by qualified personnel in accordance with local and national electrical codes.
- Ensure the power supply matches the unit's specifications (208/230 V).
- Musalowetse zala kapena zinthu mu malo olowera mpweya.
- Osayesa kukonza kapena kusintha gawolo nokha. Lumikizanani ndi ogwira ntchito oyenerera.
- Onetsetsani malo oyenera kuti musagwedezeke ndi magetsi.
- The system uses R-32 refrigerant. Handle with care and ensure proper ventilation during service.
Kukhazikitsa ndi Kuyika
Kutulutsa
Carefully unpack all components. Verify that all parts are present and undamaged. Refer to the packing list provided with your system.
Zofunikira za Malo
- Indoor Unit (FTXM18WVJU9): Mount on a wall with sufficient structural support, away from direct sunlight or heat sources. Ensure adequate clearance for air circulation.
- Outdoor Unit (RXM18WVJU9): Install on a level, stable surface outdoors, away from obstructions that could impede airflow. Ensure proper drainage and accessibility for maintenance.
Kulumikizana kwamagetsi
Connect the units to a dedicated 208/230 V power supply circuit. All wiring must comply with local electrical codes and the wiring diagram provided in the full installation manual. A qualified electrician must perform electrical connections.
Refrigerant Piping
Connect the refrigerant lines between the indoor and outdoor units. Ensure proper vacuuming and charging with R-32 refrigerant. This procedure requires specialized tools and expertise and must be performed by a certified HVAC technician.
Malangizo Ogwiritsira Ntchito
Kutalikira Kwambiriview
The system is operated via a wireless remote control. Familiarize yourself with the buttons and display on the remote control.
Basic Operation Modes
- Kuzizira: Press the MODE button until the snowflake icon appears. Adjust the temperature using the UP/DOWN arrows.
- Kutentha: Press the MODE button until the sun icon appears. Adjust the temperature using the UP/DOWN arrows.
- Mafilimu angaphunzitse: Press the MODE button until the fan icon appears. This circulates air without heating or cooling.
- Njira Yowuma: Press the MODE button until the water drop icon appears. This mode helps reduce humidity.
- Auto mumalowedwe: The system automatically selects cooling or heating based on the set temperature and ambient conditions.
Adjusting Fan Speed and Airflow Direction
- Use the FAN button to cycle through fan speed settings (Low, Medium, High, Auto).
- Use the SWING button to adjust the vertical airflow direction or enable continuous swing.
Ntchito za Timer
The remote control allows you to set ON/OFF timers for scheduled operation. Refer to the remote control manual for detailed instructions on setting timers.
Kusamalira
Regular maintenance ensures optimal performance and longevity of your Daikin system. Always turn off the power supply to the unit before performing any maintenance.
Air Filter Cleaning (Indoor Unit)
- Tsegulani gulu lakutsogolo la chipinda chamkati.
- Chotsani zosefera mpweya.
- Clean the filters using a vacuum cleaner or wash them with lukewarm water. Allow them to dry completely before reinstallation.
- Reinstall the filters and close the front panel.
pafupipafupi: Clean filters every two weeks or more frequently depending on usage and air quality.
Outdoor Unit Cleaning
Periodically remove leaves, dust, and other debris from around the outdoor unit. Ensure the condenser coils are clean and free of obstructions. Do not use high-pressure water directly on electrical components.
Kuyendera akatswiri
It is recommended to have a qualified HVAC technician perform a comprehensive inspection and service at least once a year. This includes checking refrigerant levels, electrical connections, and overall system performance.
Kusaka zolakwika
Musanayambe kulankhulana ndi utumiki, review zinthu zotsatirazi wamba ndi zothetsera.
| Vuto | Chifukwa Chotheka | Yankho |
|---|---|---|
| Unit sikugwira ntchito | No power supply; Remote control batteries low; Timer function active | Check circuit breaker; Replace remote batteries; Cancel timer setting |
| Kuzizira kosakwanira/kutenthetsa | Dirty air filters; Blocked outdoor unit; Incorrect temperature setting; Doors/windows open | Clean air filters; Clear obstructions from outdoor unit; Adjust temperature; Close doors/windows |
| Phokoso losazolowereka | Loose parts; Obstruction in fan; Unit not level | Contact service technician; Check for debris; Ensure unit is level |
| Water leakage (indoor unit) | Clogged drain pipe; Unit not level | Contact service technician to clear drain; Ensure unit is level |
If the problem persists after attempting these solutions, please contact Daikin customer support or a certified service technician.
Zofotokozera
Key technical specifications for the Daikin ATMOSPHERA 18K BTU Heat Pump Hi-Wall Fan Coil System.
| Mbali | Kufotokozera |
|---|---|
| Nambala Zachitsanzo | Outdoor: RXM18WVJU9, Indoor: FTXM18WVJU9 |
| Mphamvu | 1.5 Tons (18,000 BTU/h nominal) |
| Kuzirala kwa Mphamvu Range | 9,000 - 22,000 BTU/h |
| Kutentha Mphamvu Range | 9,000 - 30,200 BTU/h |
| Magetsi | 208/230 V |
| Mtundu wa Refriji | R-32 |
| Outdoor Unit Dimensions (H x W) | 28.9375x34.25 pa |
| Kunja Unit Kulemera | 132 lbs |
| Indoor Unit Dimensions (H x W x D) | 11.75 x 43.3125 x 10.8125 mainchesi |
| Indoor Unit Weight | 33 lbs |
| Mulingo wa Phokoso (M'nyumba) | 20 dB (osachepera) |
| Zapadera | Dust Filter, Fast Cooling, Heating & Cooling Function, Inverter Compressor, Remote Controlled |
Chitsimikizo ndi Thandizo
For warranty information, please refer to the warranty card included with your product or visit the official Daikin website. For technical support, service requests, or to locate an authorized Daikin service provider, please contact Daikin customer service.
Daikin Customer Support: Visit Daikin's official contact page