DAIKIN RXM18WVJU9, FTXM18WVJU9

Buku Lothandizira la Daikin ATMOSPHERA 18K BTU Heat Pump Hi-Wall Fan Coil System

Models: RXM18WVJU9 (Outdoor Unit), FTXM18WVJU9 (Indoor Unit)

Mawu Oyamba

This manual provides essential information for the safe and efficient operation of your Daikin ATMOSPHERA 18K BTU Heat Pump Hi-Wall Fan Coil System. This system comprises an RXM18WVJU9 outdoor unit and an FTXM18WVJU9 indoor unit. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper use and to prevent damage or injury.

Daikin ATMOSPHERA 18K BTU Heat Pump Hi-Wall Fan Coil System, showing both indoor and outdoor units.

Chithunzi 1: Daikin ATMOSPHERA 18K BTU Heat Pump Hi-Wall Fan Coil System. The image displays the white, rectangular indoor unit positioned above the larger, off-white outdoor unit with a prominent fan grille.

Chitetezo

  • Installation must be performed by qualified personnel in accordance with local and national electrical codes.
  • Ensure the power supply matches the unit's specifications (208/230 V).
  • Musalowetse zala kapena zinthu mu malo olowera mpweya.
  • Osayesa kukonza kapena kusintha gawolo nokha. Lumikizanani ndi ogwira ntchito oyenerera.
  • Onetsetsani malo oyenera kuti musagwedezeke ndi magetsi.
  • The system uses R-32 refrigerant. Handle with care and ensure proper ventilation during service.

Kukhazikitsa ndi Kuyika

Kutulutsa

Carefully unpack all components. Verify that all parts are present and undamaged. Refer to the packing list provided with your system.

Zofunikira za Malo

  • Indoor Unit (FTXM18WVJU9): Mount on a wall with sufficient structural support, away from direct sunlight or heat sources. Ensure adequate clearance for air circulation.
  • Outdoor Unit (RXM18WVJU9): Install on a level, stable surface outdoors, away from obstructions that could impede airflow. Ensure proper drainage and accessibility for maintenance.

Kulumikizana kwamagetsi

Connect the units to a dedicated 208/230 V power supply circuit. All wiring must comply with local electrical codes and the wiring diagram provided in the full installation manual. A qualified electrician must perform electrical connections.

Refrigerant Piping

Connect the refrigerant lines between the indoor and outdoor units. Ensure proper vacuuming and charging with R-32 refrigerant. This procedure requires specialized tools and expertise and must be performed by a certified HVAC technician.

Malangizo Ogwiritsira Ntchito

Kutalikira Kwambiriview

The system is operated via a wireless remote control. Familiarize yourself with the buttons and display on the remote control.

Basic Operation Modes

  • Kuzizira: Press the MODE button until the snowflake icon appears. Adjust the temperature using the UP/DOWN arrows.
  • Kutentha: Press the MODE button until the sun icon appears. Adjust the temperature using the UP/DOWN arrows.
  • Mafilimu angaphunzitse: Press the MODE button until the fan icon appears. This circulates air without heating or cooling.
  • Njira Yowuma: Press the MODE button until the water drop icon appears. This mode helps reduce humidity.
  • Auto mumalowedwe: The system automatically selects cooling or heating based on the set temperature and ambient conditions.

Adjusting Fan Speed and Airflow Direction

  • Use the FAN button to cycle through fan speed settings (Low, Medium, High, Auto).
  • Use the SWING button to adjust the vertical airflow direction or enable continuous swing.

Ntchito za Timer

The remote control allows you to set ON/OFF timers for scheduled operation. Refer to the remote control manual for detailed instructions on setting timers.

Kusamalira

Regular maintenance ensures optimal performance and longevity of your Daikin system. Always turn off the power supply to the unit before performing any maintenance.

Air Filter Cleaning (Indoor Unit)

  1. Tsegulani gulu lakutsogolo la chipinda chamkati.
  2. Chotsani zosefera mpweya.
  3. Clean the filters using a vacuum cleaner or wash them with lukewarm water. Allow them to dry completely before reinstallation.
  4. Reinstall the filters and close the front panel.

pafupipafupi: Clean filters every two weeks or more frequently depending on usage and air quality.

Outdoor Unit Cleaning

Periodically remove leaves, dust, and other debris from around the outdoor unit. Ensure the condenser coils are clean and free of obstructions. Do not use high-pressure water directly on electrical components.

Kuyendera akatswiri

It is recommended to have a qualified HVAC technician perform a comprehensive inspection and service at least once a year. This includes checking refrigerant levels, electrical connections, and overall system performance.

Kusaka zolakwika

Musanayambe kulankhulana ndi utumiki, review zinthu zotsatirazi wamba ndi zothetsera.

VutoChifukwa ChothekaYankho
Unit sikugwira ntchitoNo power supply; Remote control batteries low; Timer function activeCheck circuit breaker; Replace remote batteries; Cancel timer setting
Kuzizira kosakwanira/kutenthetsaDirty air filters; Blocked outdoor unit; Incorrect temperature setting; Doors/windows openClean air filters; Clear obstructions from outdoor unit; Adjust temperature; Close doors/windows
Phokoso losazolowerekaLoose parts; Obstruction in fan; Unit not levelContact service technician; Check for debris; Ensure unit is level
Water leakage (indoor unit)Clogged drain pipe; Unit not levelContact service technician to clear drain; Ensure unit is level

If the problem persists after attempting these solutions, please contact Daikin customer support or a certified service technician.

Zofotokozera

Key technical specifications for the Daikin ATMOSPHERA 18K BTU Heat Pump Hi-Wall Fan Coil System.

MbaliKufotokozera
Nambala ZachitsanzoOutdoor: RXM18WVJU9, Indoor: FTXM18WVJU9
Mphamvu1.5 Tons (18,000 BTU/h nominal)
Kuzirala kwa Mphamvu Range9,000 - 22,000 BTU/h
Kutentha Mphamvu Range9,000 - 30,200 BTU/h
Magetsi208/230 V
Mtundu wa RefrijiR-32
Outdoor Unit Dimensions (H x W)28.9375x34.25 pa
Kunja Unit Kulemera132 lbs
Indoor Unit Dimensions (H x W x D)11.75 x 43.3125 x 10.8125 mainchesi
Indoor Unit Weight33 lbs
Mulingo wa Phokoso (M'nyumba)20 dB (osachepera)
ZapaderaDust Filter, Fast Cooling, Heating & Cooling Function, Inverter Compressor, Remote Controlled

Chitsimikizo ndi Thandizo

For warranty information, please refer to the warranty card included with your product or visit the official Daikin website. For technical support, service requests, or to locate an authorized Daikin service provider, please contact Daikin customer service.

Daikin Customer Support: Visit Daikin's official contact page

Zolemba Zofananira - RXM18WVJU9, FTXM18WVJU9

Preview Daikin Control Devices for Hydronic Systems 2025
Explore Daikin's advanced control solutions for hydronic systems, designed to enhance efficiency, reliability, and user comfort in HVAC applications. Discover intelligent control systems, individual control solutions, and remote monitoring capabilities.
Preview Daikin DR96SN / DD96SN Single-Stage 9-Speed ECM Gas Furnace - Specifications and Features
Comprehensive guide to the Daikin DR96SN and DD96SN single-stage, 9-speed ECM gas furnaces, detailing features, specifications, dimensions, airflow data, nomenclature, wiring diagrams, and available accessories. These high-efficiency furnaces offer up to 97% AFUE and are designed for reliable residential heating.
Preview Horizontal Two-Way Coil Installation Instructions | HVAC Equipment
Comprehensive installation guide for Daikin, Goodman, and Amana horizontal two-way HVAC coils, covering safety, application, drain piping, refrigerant lines, and start-up procedures.
Preview Malangizo Okhazikitsa ndi Kukhazikitsa Daikin Unitary Aux Heater
Buku lothandizira kukhazikitsa ndi kukhazikitsa Daikin Unitary Aux Heater ndi Daikin One+ thermostat, lomwe limafotokoza mawaya, makonzedwe, ndi zowongolera pazochitika zosiyanasiyana zotenthetsera.
Preview CHPEA Series Horizontal Cased Coil Installation Instructions | Daikin, Goodman, Amana
Comprehensive installation manual for the Daikin, Goodman, and Amana CHPEA Series Two Way Horizontal Cased Coil. Covers safety, R-32 refrigerant, A2L requirements, wiring, piping, and troubleshooting for HVAC professionals.
Preview Daikin Altherma 4 H: Pompe di Calore Aria-Acqua ad Alta Temperatura ndi Refrigerante R-290
Scopri la gamma Daikin Altherma 4 H, pompe di calore aria-acqua ad alta temperatura che utilizzano il refrigerante R-290 ecologico per riscaldamento, raffrescamento e acqua calda sanitaria. Soluzioni flessibili ed efficienti per ogni esigenza abitativa e commerciale.