OLMO 18K-12K+12K

Buku Lophunzitsira la OLMO 18,000 BTU Dual Zone 12K+12K Mini Split A/C ndi Heater

Model: 18K-12K+12K

Mawu Oyamba

This manual provides essential instructions for the installation, operation, and maintenance of your OLMO 18,000 BTU Dual Zone Mini Split Air Conditioner and Heater (Model: 18K-12K+12K). Please read this manual thoroughly before using the unit to ensure proper function and safety. Retain this manual for future reference.

Zofunika Zachitetezo

Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury to persons. This unit operates on 208-230V and requires professional installation. Do not attempt to install or repair the unit yourself.

  • Ensure the power supply matches the unit's requirements (208-230V).
  • Do not block air inlets or outlets of the indoor or outdoor units.
  • Sungani ana kutali ndi gulu.
  • Turn off the power supply before cleaning or performing maintenance.
  • Contact qualified service personnel for repairs.

Zida Zopangira

The OLMO 18,000 BTU Dual Zone Mini Split system includes the following main components:

  • One (1) Outdoor Condenser Unit (18,000 BTU)
  • Two (2) Wall Mount Indoor Air Handlers (12,000 BTU each)
  • Two (2) Remote Controls
  • Two (2) 16ft Pre-Flared and Insulated Copper Line Sets
  • Two (2) Communication Wires
  • Two (2) 16ft Drainage Extensions with accessories
OLMO Dual Zone Mini Split System Components
Chithunzi: Zathaview of the OLMO Dual Zone Mini Split system components, including the outdoor condenser, two indoor wall-mount units, two remote controls, and installation kits.

This image displays the complete package: the outdoor condenser, two indoor wall-mount units, two remote controls, and the necessary installation kits, including copper line sets, communication wires, and drainage extensions.

Kukhazikitsa ndi Kuyika

Professional installation is required for this equipment. Improper installation can lead to electric shock, fire, water leakage, and other hazards. Ensure that the installation is performed by a qualified HVAC technician.

Muuni Yoyikiratu:

  • Verify that the power supply meets the unit's specifications (208-230V).
  • Ensure adequate space for both indoor and outdoor units, allowing for proper airflow and maintenance access.
  • Confirm all included components are present (refer to "Product Components" section).
  • Prepare necessary tools and safety equipment for installation.

Installation Kit Details:

The system includes a 16ft installation kit for each air handler, comprising:

  • 99.9% Copper (ASTM B-280) Pre-insulated (ASTM D154) UV & UV-C Protected Pre-flared Line Set
  • 4/16 AWG Connecting Cable
  • Rubberized 16' Drainage Hose
  • Bandage Tape
  • Manja a Wall
  • Neoprene
OLMO Mini Split Installation Kit
Chithunzi: Zambiri view of the included installation kit components, such as copper line sets, drainage hose, and electrical cables.

This image illustrates the various parts of the installation kit, including the pre-flared copper line sets, communication wires, drainage hose, and other small accessories required for connecting the indoor and outdoor units.

Outdoor Condenser Placement:

The outdoor condenser unit should be placed on a stable, level surface, away from direct sunlight and obstructions that could impede airflow. Ensure sufficient clearance around the unit for proper ventilation and maintenance.

OLMO Outdoor Condenser Unit
Chithunzi: Chapafupi view of the OLMO outdoor condenser unit, highlighting its fan and protective grille.

This image shows the outdoor condenser unit, which houses the compressor and fan. Proper placement is crucial for efficient operation and heat dissipation.

Malangizo Ogwiritsira Ntchito

Your OLMO Mini Split system can be controlled via the included remote control or through the OLMO Remote app on your smartphone using smart port adapters.

Ntchito Zakutali:

OLMO Mini Split Remote Control
Image: The OLMO Mini Split remote control, displaying various buttons for mode selection, temperature adjustment, fan speed, and special functions.

This image displays the remote control for the OLMO Mini Split system. Key functions include:

  • Batani Lamphamvu: Kuyatsa kapena kuzimitsa unit.
  • Batani la Modi: Cycles through operating modes (Cool, Heat, Dry, Fan, Auto).
  • Kusintha kwa Kutentha: Up/Down arrows to set desired temperature.
  • Liwiro la Mafani: Adjusts fan intensity (Low, Medium, High, Auto).
  • Njira Yogona: Zimathandizira kutentha ndi liwiro la fan kuti munthu agone bwino.
  • Nthawi: Sets a timer for automatic on/off operations.
  • Louver Auto Swing: Controls the vertical movement of the air louvers.
  • Chete: Amachepetsa phokoso la ntchito.
  • Njira Yachuma: Energy-saving operation.

Smartphone App Control:

The OLMO Remote app allows you to control each air handler individually from your smartphone. Smart port adapters are included for this functionality.

OLMO Smart Connect App Interface
Image: A smartphone screen displaying the OLMO Smart Connect app interface, showing temperature settings, mode selection, and other control options.

This image illustrates the user interface of the OLMO Smart Connect app on a smartphone, demonstrating how users can remotely monitor and adjust settings such as temperature, operating mode, and fan speed for their mini split units.

Njira Zogwirira Ntchito:

  • Kuzizira: Provides cooling by removing heat from the indoor space.
  • Kutentha: Provides heating, effective down to -13°F ambient temperature.
  • Dry Mode (Dehumidification): Amachepetsa chinyezi m'chipinda.
  • Mafilimu angaphunzitse: Imazungulira mpweya popanda kutentha kapena kuziziritsa.
  • Auto mumalowedwe: Automatically selects cooling or heating based on the set temperature and room temperature.

Kusamalira

Regular maintenance ensures optimal performance and extends the lifespan of your OLMO Mini Split system. Always disconnect power before performing any maintenance.

Kuyeretsa Zosefera:

  • The indoor unit's air filters should be cleaned every two weeks or more frequently depending on usage and air quality.
  • Open the front panel of the indoor unit and remove the filters.
  • Wash filters with lukewarm water and a mild detergent. Rinse thoroughly and allow to air dry completely before reinserting.
  • Osagwiritsa ntchito chipangizocho popanda zosefera.

Kuyeretsa Zipangizo Zakunja:

  • Periodically clean the outdoor unit's coils and fan blades to remove dust, leaves, and other debris.
  • Use a soft brush or vacuum cleaner. Avoid bending the coil fins.
  • Ensure the drainage outlet is clear of obstructions.

Kuyendera akatswiri:

It is recommended to have a qualified technician inspect the system annually to check refrigerant levels, electrical connections, and overall system health.

Kusaka zolakwika

Musanayambe kulankhulana ndi utumiki, review zinthu zotsatirazi wamba ndi zothetsera:

VutoChifukwa ChothekaYankho
Chigawo sichinayambeNo power; Remote control batteries low; Timer function active.Check power supply; Replace remote batteries; Deactivate timer.
Kuzizira kosakwanira/kutenthetsaDirty air filters; Blocked air inlets/outlets; Incorrect temperature setting; Doors/windows open.Clean air filters; Clear obstructions; Adjust temperature; Close doors/windows.
Kutuluka kwa madzi kuchokera m'chipinda chamkatiClogged drain hose; Improper installation.Clear drain hose; Contact professional for inspection.
Phokoso losazolowerekaZigawo zotayirira; Cholepheretsa mu fani; Chigawo sichili pamlingo.Inspect for loose parts; Remove obstructions; Ensure unit is level. If noise persists, contact service.

Ngati vutoli likupitirira mutayesa njira izi, chonde funsani ogwira ntchito oyenerera.

Zofotokozera Zamalonda

Below are the key specifications for the OLMO 18,000 BTU Dual Zone Mini Split A/C and Heater (Model: 18K-12K+12K).

MbaliKufotokozera
MtunduMtengo wa ELM
Nambala ya Model18K-12K+12K
Mtundu wa SystemDual Zone Ductless Mini Split A/C and Heater
Outdoor Condenser Capacity18,000 BTU
Indoor Air Handler Capacity (each)12,000 BTU
VoltageVolts 208-230
Kuchuluka kwa SEER221
Heating Ambient Temperature RangeKutsika mpaka -13°F
Refrigerantndi R410A
Mtundu WoyikaSplit System, Wall Mount
ZitsimikizoUL Listed, AHRI Certified, Energy Star
Miyeso ya Zamalonda (Gawo lakunja)48 x 40 x 40 inches (approximate shipping dimensions)
Mtundu WazinthuMkuwa, Pulasitiki
OLMO Outdoor Unit Specifications Table
Image: Table detailing outdoor unit specifications for various OLMO models, including cooling/heating capacity, EER2, SEER2, HSPF2, dimensions, and refrigerant type.

This image presents a detailed table of outdoor unit specifications, including power supply, cooling and heating capacities, efficiency ratings (EER2, SEER2, HSPF2), dimensions, and refrigerant information for different OLMO outdoor models. The 18,000 BTU model (OS-MSR18-230VO) is relevant to this manual.

OLMO Indoor Unit Specifications Table
Image: Table detailing indoor unit specifications for various OLMO models, including cooling/heating capacity, power, current, airflow, noise level, and dimensions.

This image provides a comprehensive table of indoor unit specifications, covering power supply, cooling and heating capacities, output power, rated current, indoor airflow, noise levels, and net dimensions for various OLMO indoor models. The 12,000 BTU model (OS-MS12SRW-230VI) is relevant to this manual.

Chitsimikizo ndi Thandizo

OLMO provides a limited warranty for this product:

  • 5 Years Limited chitsimikizo pa kompresa.
  • 2 Years Limited chitsimikizo on parts.

For warranty claims or technical support, please contact OLMO customer service. Ensure you have your model number (18K-12K+12K) and proof of purchase available.

OLMO 5 Year Compressor and 2 Year Parts Warranty
Image: Graphic indicating a 5-year limited warranty on the compressor and a 2-year limited warranty on parts for OLMO products.

This image visually confirms the warranty terms: a 5-year limited warranty for the compressor and a 2-year limited warranty for other parts, providing assurance of product quality and support.

Zolemba Zofananira - 18K-12K+12K

Preview Buku la Ogwiritsa Ntchito la OLMO Split Air Conditioner yokhala ndi Heat Pump
Comprehensive user manual for the OLMO Split Air Conditioner with Heat Pump, covering safety precautions, unit specifications, features, care and maintenance, and troubleshooting.
Preview Buku Lokhazikitsa la OLMO OS-EAH36-230VO la Central Split Air Handler Outdoor Unit
Pezani malangizo atsatanetsatane okhazikitsa chipangizo chakunja cha OLMO OS-EAH36-230VO chokhala ndi malo ambiri cha AHU. Bukuli likufotokoza za chitetezo, kukhazikitsa, mawaya, ndi kuyesa makina oziziritsira mpweya ogawanika pakati.
Preview Malangizo ndi Chitsimikizo cha OLMO Multi SIERRA Series Remote Controller
Buku lotsogolera mokwanira momwe mungagwiritsire ntchito chowongolera mpweya choziziritsira cha OLMO Multi SIERRA Series, kuphatikiza kufotokozera kwa mawonekedwe, makonda, ndi zambiri zochepa za chitsimikizo.
Preview OLMO Multi-Zone Multi SIERRA Series Installation Manual
This installation manual provides detailed instructions for the OLMO Multi-Zone Multi SIERRA Series wall-mounted mini-split air conditioning system. It covers safety precautions, installation procedures, piping requirements, wiring, and trial runs for models OS-RMS18-230VO, OS-RMS27-230VO, OS-RMS36-230VO, and OS-RMS42-230VO.
Preview OLMO Sierra Series Wi-Fi User Manual
User manual for the OLMO Sierra Series Single-Zone Wall Mounted Mini Split Air Conditioning System, covering Wi-Fi setup and control via the ConnectLife app.
Preview Dongosolo la OLMO la Mini Split Air Conditioning System: Buku Logwiritsira Ntchito ndi Kukhazikitsa
Buku lothandizira kugwiritsa ntchito ndi kukhazikitsa makina oziziritsa mpweya a OLMO Multi-Sierra okhala ndi makoma, lomwe lili ndi mitundu ya OS-RM09SW-230VI, OS-RM12SW-230VI, OS-RM18SW-230VI, ndi OS-RM24SW-230VI. Limapereka chidziwitso chofunikira pakugwiritsa ntchito ndi kukhazikitsa.