1. Mawu Oyamba
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your RIELLO RLE 25 KIS Methane Outdoor Condensing Boiler. Please read this manual thoroughly before attempting any installation, operation, or maintenance procedures. Keep this manual in a safe place for future reference.
The RIELLO RLE 25 KIS is a high-efficiency methane condensing boiler designed for outdoor installation. It features an intuitive touch control panel with clear icons and a compact design for ease of use and integration.
2. Zofunika Zachitetezo
Your safety and the safety of others are paramount. Always adhere to the following safety guidelines:
- Kuyika Kwaukatswiri: Installation, initial startup, adjustment, and maintenance must be performed by qualified and authorized personnel in accordance with all local and national regulations.
- Chitetezo cha Gasi: This appliance uses methane gas. Ensure all gas connections are secure and leak-free. In case of a gas leak, immediately shut off the gas supply, ventilate the area, and contact emergency services. Do not operate electrical switches.
- Chitetezo cha Magetsi: Ensure the boiler is properly grounded. Do not operate the boiler with wet hands or if the electrical components are exposed to water. Disconnect power before any service or maintenance.
- Chitetezo cha Madzi: Osateroamper with the pressure relief valve. Ensure proper water pressure is maintained.
- Mpweya wabwino: As an outdoor unit, ensure its location allows for proper air circulation and exhaust discharge as per installation guidelines.
- Ana ndi Ziweto: Keep children and pets away from the boiler, especially during operation.
Kulephera kutsatira malangizowa kungawononge katundu, kuvulazidwa, kapena kufa.
3. Zamalonda Zathaview
The RIELLO RLE 25 KIS is a state-of-the-art condensing boiler designed for efficient heating and domestic hot water production. Its robust construction and advanced technology ensure reliable performance.

Chithunzi: Patsogolo view of the RIELLO RLE 25 KIS Methane Outdoor Condensing Boiler. The unit is white, rectangular, with the 'RIELLO' logo on the bottom left and 'RLE' on the bottom right. A digital display and four control buttons are visible at the bottom center.
Zofunika Kwambiri:
- Intuitive touch control panel with representative icons.
- Compact and modern design.
- Heating energy efficiency class A.
- Sanitary energy efficiency profile XL class A.
- Thermal power (heating): 25 kW.
- Hot water quantity (with 25 °C temperature rise): 14.3 l/min.
- Makulidwe: 700 x 400 x 300 mm.
- Kulemera kwake: 31kg.
4. Kukhazikitsa ndi Kuyika
Installation of the RIELLO RLE 25 KIS boiler must be carried out by a certified professional. Incorrect installation can lead to serious hazards and void the warranty. Refer to the separate detailed installation manual provided with the product for comprehensive instructions.
4.1. Macheke a Pre-Installation
- Malo: Ensure the chosen outdoor location complies with local regulations for gas appliances and provides adequate clearance for maintenance.
- Mpweya wabwino: Verify that the location allows for proper air intake and exhaust discharge.
- Gasi: Confirm the methane gas supply line is correctly sized and accessible.
- Madzi: Ensure cold water inlet and heating system return/flow lines are ready.
- Zamagetsi: A dedicated electrical circuit with appropriate voltage and current protection is required.
4.2. Mounting the Boiler
The boiler should be securely mounted on a stable, vertical surface capable of supporting its weight (31 kg). Use appropriate mounting hardware as specified in the installation manual. Ensure the unit is level.
4.3. Zothandizira Zogwirizanitsa
- Kulumikizana ndi Gasi: Connect the gas supply line to the boiler's gas inlet, ensuring all connections are sealed and tested for leaks.
- Kulumikizana ndi Madzi: Connect the heating system flow and return pipes, as well as the domestic cold water inlet and hot water outlet.
- Kulumikiza Magetsi: Wire the boiler to the dedicated electrical supply, following the wiring diagram in the installation manual.
- Kutulutsa kwa Condensate: Connect the condensate drain line to an appropriate drainage system, ensuring proper slope and trap.
5. Malangizo Ogwiritsira Ntchito
Once installed and commissioned by a professional, your RIELLO RLE 25 KIS boiler is ready for operation. The intuitive touch panel allows for easy control.
5.1. Control gulu Overview
The boiler features a digital display and several touch-sensitive buttons, each represented by an icon. These icons typically include power on/off, heating mode, domestic hot water mode, temperature adjustment, and information/reset functions. Refer to the specific icons on your boiler's panel for their exact functions.
5.2. Chiyambi choyamba
- Onetsetsani kuti valavu yamagetsi yatsegulidwa.
- Ensure the water supply valves to the boiler are open and the system pressure is within the recommended range (typically 1.0-1.5 bar).
- Switch on the electrical power to the boiler.
- Press the power button on the control panel. The boiler will initiate its startup sequence.
5.3. Adjusting Heating Settings
To adjust the desired heating temperature, navigate to the heating mode using the control panel. Use the '+' and '-' buttons (or similar icons) to set the desired temperature. The display will show the current setting.
5.4. Adjusting Domestic Hot Water (DHW) Settings
To adjust the desired domestic hot water temperature, navigate to the DHW mode. Use the '+' and '-' buttons to set the desired temperature. The boiler will prioritize hot water production when a tap is opened.
5.5. Tsekani
- Temporary Shutdown: Press the power button on the control panel. The boiler will enter standby mode.
- Complete Shutdown (for extended periods or maintenance): Turn off the electrical power supply to the boiler and close the main gas supply valve.
6. Kusamalira
Regular maintenance is crucial for the longevity, efficiency, and safe operation of your RIELLO RLE 25 KIS boiler. Neglecting maintenance can lead to reduced performance and potential safety hazards.
6.1. Kusamalira Ogwiritsa
- Kuyeretsa Kunja: Periodically wipe the exterior of the boiler with a soft, damp nsalu. Osagwiritsa ntchito zotsukira abrasive kapena solvents.
- Kuwunika kwa Pressure: Regularly check the system pressure gauge. If the pressure falls below the recommended range (e.g., 1.0 bar), repressurize the system according to the installation manual.
6.2. Professional Maintenance
It is highly recommended to have your boiler serviced annually by a qualified heating engineer. Professional maintenance typically includes:
- Inspection and cleaning of the heat exchanger.
- Kuyang'ana ndi kusintha kuthamanga kwa mpweya.
- Testing safety devices.
- Checking and cleaning the condensate trap and drain.
- Verification of electrical connections.
- Flue gas analysis.
7. Mavuto
This section provides guidance for common issues. For complex problems or if an error code persists, contact a qualified service technician.
| Vuto | Chifukwa Chotheka | Yankho |
|---|---|---|
| No heating/cold radiators | Low system pressure; Thermostat set too low; Boiler in standby mode; Gas supply off. | Check system pressure and repressurize if needed; Increase thermostat setting; Check boiler power and mode; Ensure gas valve is open. |
| Palibe madzi otentha | DHW temperature set too low; Boiler in standby mode; Water supply off. | Increase DHW temperature setting; Check boiler power and mode; Ensure water supply is open. |
| Boiler displays an error code | Various internal faults (e.g., ignition failure, sensor error, fan fault). | Note the error code and consult the detailed technical manual or contact a qualified service technician. Attempt a boiler reset if indicated by the manual. |
| Unusual noises from boiler | Air in system; Pump issue; Component wear. | Bleed radiators to remove air; If noises persist, contact a qualified service technician. |
8. Mafotokozedwe aukadaulo
| Mbali | Mtengo |
|---|---|
| Mtundu | RIELLO |
| Chitsanzo | RLE 25 KIS |
| Mtundu | Methane Outdoor Condensing Boiler |
| Heating Thermal Power | 25 kw pa |
| DHW Flow Rate (at 25°C rise) | 14.3 l/mphindi |
| Heating Energy Efficiency Class | A |
| Sanitary Energy Efficiency Profile | XL Class A |
| Makulidwe (L x W x H) | 700 x 400 x 300 mm |
| Kulemera | 31kg pa |
| Mtundu | Choyera |
9. Chitsimikizo ndi Thandizo
Your RIELLO RLE 25 KIS boiler is covered by a manufacturer's warranty. The terms and duration of the warranty are typically provided with your purchase documentation. Please retain your proof of purchase for warranty claims.
For technical support, service, or warranty inquiries, please contact your authorized RIELLO installer or the RIELLO customer service department in your region. Do not attempt to repair the boiler yourself, as this may void the warranty and pose safety risks.