Mawu Oyamba
Thank you for choosing the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System. This unit is designed to provide efficient heating and cooling for residential, commercial, or hotel use. It features a built-in wireless smart kit for convenient control via smartphone, an included remote control, and comes with a wall sleeve for installation.
This manual provides essential information for the safe and effective setup, operation, and maintenance of your OLMO unit. Please read it thoroughly before installation and use.
Figure 1: OLMO Through-the-Wall Air Conditioner and included accessories.
Kukhazikitsa ndi Kuyika
The OLMO Through-the-Wall Air Conditioner is designed for packaged installation. A wall sleeve is included with your unit to facilitate proper mounting.
Muuni Yoyikiratu:
- Verify power supply: This unit requires a 115V, 1-phase, 60Hz power supply. Ensure you have the correct receptacle.
- Check dimensions: The product dimensions are approximately 20.28 x 24.21 x 14.53 inches. Ensure your wall opening is appropriately sized for the unit and wall sleeve.
- Confirm refrigerant: The unit is pre-charged with R-32 refrigerant.
Wall Sleeve Installation:
The included wall sleeve (Model: OW-TTWSLV) is crucial for secure and proper installation. Follow the detailed instructions provided in the separate installation guide for precise measurements and mounting procedures. Proper sealing and insulation around the sleeve are essential for optimal performance and energy efficiency.

Figure 2: Included Wall Sleeve (OW-TTWSLV).
Kuyika Magawo:
Ensure the unit is installed in a location that allows for proper airflow around the intake and exhaust vents. Avoid placing objects directly in front of or on top of the unit that could obstruct air circulation.
Malangizo Ogwiritsira Ntchito
Your OLMO Through-the-Wall unit offers multiple control options for your convenience:
- Digital Push Button Control Panel: Located on the unit with an LED display for direct control.
- Included Remote Controller: Provides full functionality from a distance.
- Built-In Wireless Smart Kit: Allows control via a compatible smartphone application.
Ntchito Zakutali:
The remote control allows you to adjust temperature, change modes (Cool, Heat, Fan, Dry, Auto), set fan speeds, and activate special features like Sleep Mode and Timer.

Figure 3: Remote Control for OLMO AC Unit.
Smart Connect (Wi-Fi) Operation:
The built-in Smart Connect feature enables you to control your unit remotely using a smartphone app. Download the official OLMO app from your device's app store and follow the in-app instructions to pair your unit. This allows for convenient control from anywhere with an internet connection.

Figure 4: Smartphone App for Smart Control.
Zofunika Kwambiri:
- Njira Yogona: Adjusts temperature automatically for comfortable sleep and energy saving.
- Kuyambiranso: Chipangizocho chidzayambiranso ndi zoikamo zam'mbuyomu pambuyo pa mphamvutage.
- Kuthamanga Kwamafani Angapo: Choose from various fan speeds for customized airflow.
- Nthawi: Program the unit to turn on or off at specific times.
- Self-Evaporative System: Helps manage condensate, reducing the need for manual draining in most conditions.
- Kuwonetsera kwa LED: Provides clear indication of settings and operating status.
- Fresh Air Input: Allows for introduction of fresh outdoor air.
Kanema: Paview of OLMO Through-the-Wall Air Conditioner features and capabilities. This video demonstrates the unit's design and highlights its smart connectivity and remote control options.
Kusamalira
Regular maintenance ensures optimal performance and longevity of your OLMO air conditioner. Always disconnect power to the unit before performing any maintenance.
Kuyeretsa Zosefera:
The air filter should be cleaned every two weeks, or more frequently depending on usage and air quality. A dirty filter can reduce cooling/heating efficiency and airflow.
- Open the front panel of the unit.
- Carefully remove the air filter(s).
- Tsukani fyuluta ndi madzi ofunda, a sopo. Muzimutsuka bwinobwino.
- Allow the filter to air dry completely before reinserting. Do not expose to direct sunlight or heat.
General Cleaning:
Pukutani kunja kwa chipangizocho ndi chofewa, damp cloth. Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface. Ensure the drainage area is clear of debris.
Kusaka zolakwika
If you experience issues with your OLMO air conditioner, refer to the following common troubleshooting steps. For problems not listed here, or if issues persist, please contact OLMO customer support.
| Vuto | Chifukwa Chotheka | Yankho |
|---|---|---|
| Chigawo sichiyatsa | No power supply; Circuit breaker tripped; Unit unplugged. | Check power cord connection; Reset circuit breaker; Ensure unit is plugged into a functional 115V outlet. |
| Kuzizira kosakwanira/kutenthetsa | Dirty air filter; Obstructed airflow; Temperature setting too high/low; Room size exceeds capacity. | Clean air filter; Remove obstructions from vents; Adjust temperature setting; Ensure unit capacity matches room size. |
| Unit ndi phokoso | Loose parts; Unit not level; Fan obstruction. | Check for loose components; Ensure unit is level; Inspect fan for obstructions. |
| Kuwongolera kutali sikukugwira ntchito | Dead batteries; Obstruction between remote and unit. | Sinthani mabatire; Onetsetsani kuti cholandirira cha chipangizocho chili bwino. |
Zofotokozera
Detailed technical specifications for the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System (Model: OW-P08HS115WF/ OW-TTWSLV).
| Kufotokozera | Mtengo |
|---|---|
| Dzina la Brand | Mtengo wa ELM |
| Zambiri Zachitsanzo | OW-P08HS115WF/ OW-TTWSLV |
| Kulemera kwa chinthu | 80 mapaundi |
| Makulidwe azinthu (D x W x H) | 20.28 x 24.21 x 14.53 mainchesi |
| Dziko lakochokera | China |
| Kuchita bwino | Zabwino |
| Mphamvu | 0.66 matani |
| Mlingo wa Phokoso | 52db pa |
| Mtundu Woyika | Packaged, Through-the-Wall |
| Zapadera | Yoyendetsedwa ndi Kutali, WiFi Yoyatsidwa |
| Zinthu Zotenthetsera | 1 |
| Mtundu | Choyera |
| Voltage | 115 volts |
| Kuphatikiza Zida | Through the Wall Air Conditioner, Wall Sleeve and Remote Control |
| Kuzizira Mphamvu | 8000 British Thermal Units |
| Refrigerant | R-32 |

Figure 5: Comprehensive Technical Specifications Table.
Chitsimikizo ndi Thandizo
For technical assistance, warranty inquiries, or further support, please contact OLMO customer service. Refer to your product packaging or the official OLMO webwebusayiti kuti mudziwe zambiri zaposachedwa.
You can also visit the official OLMO store for more product information and resources: OLMO Store on Amazon.