ACiQ ACiQ-60-HPD

ACiQ 5 Ton 16 SEER2 Heat Pump Condenser

Model: ACiQ-60-HPD

Mtundu: ACiQ

Mawu Oyamba

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 5 Ton 16 SEER2 High Efficiency Heat Pump Condenser. Please read all instructions carefully before installation and use. Professional installation by a certified technician is required to ensure proper function and warranty validity.

ACiQ 5 Ton 16 SEER2 Heat Pump Condenser outdoor unit

Figure 1: ACiQ 5 Ton 16 SEER2 Heat Pump Condenser outdoor unit.

Kukhazikitsa ndi Kuyika

Installation of the ACiQ Heat Pump Condenser requires specialized knowledge and tools. It must be performed by a qualified HVAC technician. Key considerations include:

  • Malo Ogulitsira Zinthu Panja: Ensure adequate clearance around the unit for proper airflow and maintenance. The compact design allows for a smaller footprint compared to traditional units.
  • Firiji: This unit uses R-454B refrigerant. Proper handling and charging procedures must be followed.
  • Gawo la Air Handler: The system supports a multi-positional air handler unit, allowing for upflow, downflow, or horizontal installation to suit various ducting designs.
  • Zolumikizira zamagetsi: All electrical wiring must comply with local codes and standards.
Diagram showing ACiQ outdoor unit size comparison to traditional unit

Figure 2: Outdoor unit size comparison, highlighting the ACiQ's smaller footprint.

Diagram showing multi-positional air handler unit installation options

Figure 3: Multi-positional air handler unit for flexible installation (upflow, downflow, horizontal).

Kanema 1: Kupitiliraview of ACiQ HPD/EHPD Condenser and System features, including installation flexibility.

Malangizo Ogwiritsira Ntchito

Your ACiQ Heat Pump Condenser is designed for high efficiency and reliable performance across a wide range of temperatures. It features advanced inverter technology for precise temperature control and reduced energy consumption.

  • Kutentha: This unit delivers reliable warmth down to -22°F and provides effective cooling up to 122°F.
  • Kuchita Kwachete: The inverter technology ensures whisper-quiet operation, minimizing noise disruptions.
  • Smart Control: Compatible with Wi-Fi smart thermostats for convenient control and optimization of your home's climate.
Image showing ACiQ unit operating in extreme cold and extreme heat

Figure 4: The ACiQ unit's capability to operate in extreme cold (down to -22°F) and extreme heat (up to 122°F).

Image highlighting the quiet operation of the ACiQ heat pump

Figure 5: The ACiQ heat pump operates quietly, ensuring no interruptions.

Video 2: ACiQ HPD System overview, demonstrating its performance and features.

Kusamalira

Regular maintenance is crucial for the longevity and efficiency of your ACiQ Heat Pump Condenser. While some tasks can be performed by the homeowner, annual professional servicing is highly recommended.

  • Ntchito Yodziyeretsa: The unit features a self-cleaning mechanism that automatically clears debris, reducing the need for frequent manual cleaning.
  • Kusintha Sefa: Regularly check and replace air filters in your indoor air handler unit as per manufacturer recommendations to maintain optimal airflow and air quality.
  • Kuyendera akatswiri: Schedule annual inspections and tune-ups with a certified HVAC technician to ensure all components are functioning correctly and to prevent potential issues.
Image showing the self-cleaning feature of the ACiQ unit

Figure 6: The ACiQ unit's self-cleaning feature automatically clears debris.

Kusaka zolakwika

If you experience issues with your ACiQ Heat Pump Condenser, consider the following basic troubleshooting steps. For complex problems, always contact a qualified technician.

  • Palibe Mphamvu: Yang'anani chodulira magetsi ndikuwonetsetsa kuti chipangizocho chalumikizidwa bwino ndi magetsi.
  • Insufficient Heating/Cooling: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is free of obstructions.
  • Phokoso Lachilendo: Minor noises are normal during operation. However, loud or persistent unusual noises may indicate a problem and require professional inspection.
  • Makhodi Olakwika: If your thermostat or unit displays an error code, consult your technician or the full product manual for specific meanings and solutions.

Do not attempt to repair internal components yourself. This can void your warranty and pose safety risks.

Zofotokozera

MbaliTsatanetsatane
Dzina la BrandMtengo wa ACiQ
Nambala ya ModelACiQ-60-HPD
Miyeso Yazinthu16.34"D x 37.48"W x 52.48"H
Efficiency (SEER2)16 SEER2 (18.0 SEER)
Mphamvu5 Ton (60,000 BTU) / 4.69 Tons
Mlingo wa Phokoso56 decibels
Mtundu WoyikaSplit System
Fomu FactorSplit System
ZapaderaInverter Condenser, Learning System
RefrigerantR-454B
Gwero la MphamvuCorded Electric
Cooling capacity chart for ACiQ heat pump

Figure 7: Cooling Capacity performance at various ambient temperatures.

Heating capacity chart for ACiQ heat pump

Figure 8: Heating Capacity performance at various ambient temperatures.

Chidziwitso cha Chitsimikizo

Your ACiQ Heat Pump Condenser comes with a comprehensive warranty:

  • 7-Zaka Part chitsimikizo
  • Chitsimikizo cha Compressor cha Zaka 12

These warranty terms are valid when the unit is installed by a certified technician and registered online with the manufacturer at no additional charge. Please retain your proof of purchase and installation records for warranty claims.

Image detailing ACiQ warranty coverage terms

Figure 9: Warranty coverage terms for ACiQ products.

Thandizo

For technical assistance, service, or any questions regarding your ACiQ Heat Pump Condenser, please contact your certified ACiQ dealer or the manufacturer's support team. Our dedicated support team is available to provide assistance.

Visit the official ACiQ webtsamba lawebusayiti kuti mupeze zinthu zina zowonjezera, Mafunso Ofunsidwa Kawirikawiri, ndi zambiri zolumikizirana: ACiQ Store

Zolemba Zofananira - ACiQ-60-HPD

Preview ACiQ Extreme+ Ducted Air Handler Installation Manual (18K-60K)
Installation manual for ACiQ Extreme+ Ducted Air Handler (18K-60K) models, detailing safety, unit setup, refrigerant, wiring, and testing procedures for qualified technicians.
Preview Buku Loyambira Mwachangu la ACiQ High Efficiency Heat Pump System: Standard and Extreme Series with R-454B
Buku loyambira mwachangu lokhazikitsa ndi kulumikiza ACiQ High Efficiency Heat Pump Systems (Standard and Extreme Series with R-454B). Limaphimba mawaya a thermostat, ma DIP switch, ndi makonzedwe oyambira pazochitika zosiyanasiyana zoyika.
Preview ACiQ Ducted Air Handler Installation Manual: Models 12K-60K
Buku lathunthu lokhazikitsa mayunitsi a ACiQ Ducted Air Handler, okhala ndi mitundu kuyambira 12K mpaka 60K BTU. Amapereka malangizo atsatanetsatane, zodzitetezera, zojambula zamawaya, ndi mafotokozedwe oyenera kukhazikitsa ndi kukhazikitsa.
Preview ACiQ EXTREME+ Ducted Air Handler Installation Manual (18K-60K)
Buku lathunthu loyika makina a ACiQ EXTREME+ Ducted Air Handler, okhala ndi mitundu kuyambira 18K mpaka 60K BTU. Zimaphatikizapo zodzitetezera, njira zoyika, mawaya, ndi kuyesa.
Preview ACiQ Wall-Mounted Air Handler & Extreme Heat Single-Zone Condenser Installation & Owner's Manual
This manual provides detailed installation, operation, and safety guidelines for ACiQ wall-mounted air handlers and extreme heat single-zone condensers, covering models ACIQ-06W-HH-MD through ACIQ-24ZPL-HP230C.
Preview ACiQ Extreme Heat Single-Zone Condenser & Bukhu Lomangira Lobisala Duct Air Handler
Buku loyika la ACiQ Extreme Heat Single-Zone Condenser ndi Concealed Duct Air Handler systems (models ACIQ-09CD-HH-MC to ACIQ-60CD-HH-MC and ACIQ-09ZPL-HP230C to ACIQ-60ZPL-HP230C). Zimaphatikizapo chitetezo, masitepe oyika, ndi mafotokozedwe.