1. Mawu Oyamba
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 4 Ton 16.5 SEER2 High Efficiency Heat Pump Condenser. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.

Figure 1: ACiQ 4 Ton 16.5 SEER2 High Efficiency Heat Pump Condenser outdoor unit.
2. Zambiri Zachitetezo
Always adhere to local codes and regulations. Installation and servicing must be performed by qualified, licensed HVAC technicians. Failure to do so can result in property damage, personal injury, or death, and may void your warranty.
- Chitetezo cha Magetsi: Ensure the power supply is disconnected before performing any maintenance or service.
- Kusamalira Refrigerant: This unit uses R454B refrigerant. Only certified personnel should handle refrigerants.
- Mphepete Zakuthwa: Exercise caution when handling components, as some parts may have sharp edges.
- Zipangizo Zolemera: The unit is heavy. Use proper lifting techniques and equipment during installation to prevent injury.
3. Zinthu Zogulitsa
The ACiQ 4 Ton 16.5 SEER2 Heat Pump Condenser is designed for high efficiency and reliable performance across a wide range of temperatures.
- Extreme Heat Technology: Provides consistent heating performance down to -22°F (-30°C) and maintains full heating power at 0°F (-18°C).
- Tekinoloje ya Inverter: Advanced inverter compressor adjusts power output to match demand, ensuring precise temperature control, reduced energy consumption, and quieter operation.
- Kuchita Pawiri: Offers both powerful heating and efficient cooling for year-round comfort.
- Zomangamanga Zolimba: Features an aluminum coil for long-lasting reliability and fiberglass-free insulation to enhance efficiency and reduce condensation.
- All-Season Performance: Equipped with a chassis and crankcase heater for winter protection and high-temperature cooling capabilities for summer operation.

Figure 2: Unit operating effectively in cold temperatures, down to -22°F.

Figure 3: Unit operating effectively in hot temperatures, up to 122°F.
4. Kukhazikitsa ndi Kuyika
The ACiQ Heat Pump Condenser is designed as part of a split system. Proper installation requires professional expertise to ensure optimal performance, safety, and compliance with all applicable codes.
4.1 Kusankha Kwatsamba
Choose a location for the outdoor unit that allows for adequate airflow, minimizes noise disturbance, and provides easy access for maintenance. Ensure the unit is installed on a level, stable surface.

Figure 4: The compact design of the ACiQ outdoor unit compared to traditional systems.
4.2 Air Handler Unit Compatibility
This condenser is compatible with multi-positional air handler units, allowing for flexible installation in upflow, downflow, or horizontal configurations.

Figure 5: Various installation orientations for the indoor air handler unit.
4.3 Kulumikiza Magetsi ndi Mafiriji
All electrical wiring and refrigerant line connections must be performed by a licensed technician according to the wiring diagrams provided with the unit and all local and national electrical codes.
5. Malangizo Ogwiritsira Ntchito
Once installed, your ACiQ Heat Pump Condenser will work in conjunction with your indoor air handler and thermostat to maintain desired temperatures.
- Kuwongolera kwa Thermostat: Use your compatible thermostat to set desired heating or cooling modes and temperatures.
- Inverter ntchito: The inverter technology allows the unit to modulate its capacity, providing consistent comfort and energy savings. Expect quieter operation compared to traditional on/off systems.
- Seasonal Transitions: The system automatically switches between heating and cooling modes based on thermostat settings and ambient conditions.
6. Kusamalira
Regular maintenance ensures the efficiency and longevity of your heat pump system. It is recommended to have a qualified technician perform annual inspections and servicing.
- Chipinda Choyera Panja: Sungani malo ozungulira chipinda chakunja opanda zinyalala, masamba, ndi zomera kuti mpweya uziyenda bwino.
- Kuyeretsa Koyilo: The unit features a self-cleaning function. For deeper cleaning, consult a professional.
- Kusintha Sefa: Regularly check and replace the air filters in your indoor air handler unit as per its manual.
- Ngalande: Onetsetsani kuti mzere wothira madzi oundana uli woyera komanso wopanda zopinga.

Figure 6: Maintain clear surroundings for optimal unit performance.
7. Mavuto
Musanayambe kulumikizana ndi chithandizo chamakasitomala, review mavuto ndi mayankho ofala awa.
| Vuto | Chifukwa Chotheka | Yankho |
|---|---|---|
| Unit osayatsa | No power, tripped breaker, thermostat issue | Check power supply and circuit breaker. Verify thermostat settings. |
| Kutentha/kuzizira kosakwanira | Dirty air filter, blocked outdoor unit, low refrigerant | Clean/replace air filter. Clear debris from outdoor unit. Contact a technician for refrigerant check. |
| Phokoso lachilendo | Ziwalo zotayirira, kutsekeka kwa fan, vuto la compressor | Inspect for loose panels or obstructions. If noise persists, contact a technician. |
For issues not listed or if problems persist, contact a qualified HVAC technician or ACiQ customer support.
8. Zofotokozera
| Kufotokozera | Mtengo |
|---|---|
| Mtundu | Mtengo wa ACiQ |
| Nambala ya Model | ACiQ-48-HPD |
| Mphamvu | Matani atatu (48,000 BTU) |
| SEER2 Efficiency | 16.5 |
| Mtundu wa Refriji | R454B |
| Makulidwe azinthu (D x W x H) | 16.34 x 38.58 x 38.39 mainchesi |
| Mlingo wa Phokoso | 56db pa |
| Voltage | 120 volts |
| Wattage | 14500 watts |
| Mtundu Woyika | Split System |
9. Chitsimikizo ndi Thandizo
ACiQ provides a comprehensive warranty for this product:
- 7-Zaka Part chitsimikizo
- Chitsimikizo cha Compressor cha Zaka 12
These warranty terms are valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please visit the official ACiQ website for warranty registration and detailed terms and conditions.
For technical support, service inquiries, or to locate a certified installer, please refer to the contact information provided on the ACiQ webtsamba kapena zolemba zanu zogula.