This manual provides essential information for the safe and effective operation of your OWON CM2100 Digital AC/DC Clamp Meter. Please read this manual thoroughly before use and retain it for future reference. The CM2100 is a portable, true RMS clamp meter designed for measuring AC/DC current, AC/DC voltage, resistance, capacitance, diode, and non-contact voltagndi (NCV).
Zambiri Zachitetezo
WARNING: To avoid electric shock or personal injury, read and understand all safety information before using this product.
- Nthawi zonse tsatirani malamulo a chitetezo chapafupi ndi dziko.
- Do not use the meter if it appears damaged or if the insulation is compromised.
- Osagwiritsa ntchito kuposa voliyumu yovoteratage, monga zasonyezedwa pa mita, pakati pa matheminali kapena pakati pa materminal ndi nthaka.
- Samalani mukamagwira ntchito ndi voltagndi pamwamba pa 30V AC RMS, 42V pachimake, kapena 60V DC. Voltagndi chiwopsezo chowopsa.
- Remove the test leads from the meter before opening the battery cover.
- Ensure the function switch is in the correct position for the measurement being performed.
- Osagwiritsa ntchito mita mozungulira mpweya wophulika, nthunzi, kapena fumbi.
- Always use appropriate personal protective equipment (PPE).
Zathaview ndi Components
Familiarize yourself with the various parts of your CM2100 clamp meter before operation.

Chithunzi: Detailed diagram of the OWON CM2100 clamp meter, highlighting its key components such as the NCV sensor, pincher head trigger, function selection knob, DCA reset/BLE button, function selector, NCV light, LCD display, numerical lock/backlight switch, capacity/resistance/voltage/frequency/diode/ON-OFF input jack, and common-end jack. Dimensions are also indicated.
- NCV Sensor: Detects non-contact voltage.
- Pincher Head Trigger: Amatsegula ndi kutseka clamp nsagwada.
- Ntchito Yosankha Knob: Rotates to select different measurement modes (e.g., V~, V=, A~, A=, Ω, NCV, VFC, Hz%).
- DCA Reset/BLE Button: Used for DC current zeroing and Bluetooth (BLE) activation on compatible models (CM2100B).
- Chosankha Ntchito: Toggles between specific functions within a mode (e.g., AC/DC voltage, resistance/capacitance).
- NCV Light: Illuminates to indicate non-contact voltagndi kuzindikira.
- Chiwonetsero cha LCD: Imasonyeza ziwerengero za muyeso, mayunitsi, ndi zizindikiro.
- Numerical Lock/Backlight Switch: Locks the current reading (HOLD) and activates the display backlight.
- Ma Jacks Olowetsa: For connecting test leads for voltage, resistance, capacitance, diode, and continuity measurements.
- Common-End Jack: The negative (-) input for test leads.
Zomwe zili mu Bokosi
Upon opening the package, verify that all items listed below are present and undamaged.

Chithunzi: Contents of the OWON CM2100 package, including the CM2100 clamp meter, a pair of multimeter test leads (red and black), a small bolt driver, a quick guide, and a soft carrying bag.
- OWON CM2100 Clamp Mita
- Multimeter Test Leads (Red and Black)
- Bolt Driver (for battery compartment)
- Chitsogozo Chachangu
- Chikwama Chonyamulira Chofewa
Khazikitsa
Kuyika kwa Battery
- Onetsetsani kuti mita yazimitsidwa.
- Pezani batire kumbuyo kwa mita.
- Use the provided bolt driver to loosen the screw securing the battery cover.
- Chotsani chivundikiro cha batri.
- Insert the Lithium Metal battery (included) according to the polarity markings inside the compartment.
- Sinthanitsani chivundikiro batire ndi kumangitsa wononga.
Mphamvu Yoyambira
Rotate the function selection knob from OFF to any measurement function to power on the meter. The LCD display will illuminate.
Malangizo Ogwiritsira Ntchito
Kusankha Ntchito
Rotate the central knob to select the desired measurement function. The meter features an automatic range for most measurements, simplifying operation.

Chithunzi: Zathaview of the OWON CM2100's multiple measurement functions, including Resistance (Ω), NCV, VFC, HOLD, ON/OFF (continuity), LCD, Capacitance, Diode, Overload Protection, Low Battery Alert, Buzzing Prompt, and True RMS. It also highlights the 20000 counts, auto range, AC/DC voltage, and AC/DC current measurement capabilities.
Njira zoyezera
- AC/DC Current Measurement (A~ / A=):
Rotate the knob to the 'A~' or 'A=' position. Press the trigger to open the clamp jaws and enclose a single conductor. Ensure the conductor is centered within the jaws for accurate readings. The display will show the current value. For DC current, press the DCA Reset button to zero the reading before measurement.
- AC / DC Voltage Measurement (V~ / V=):
Insert the red test lead into the VΩHz input jack and the black test lead into the COM jack. Rotate the knob to 'V~' for AC voltage or 'V=' for DC voltage. Connect the test leads in parallel to the circuit or component to be measured. The display will show the voltagndi mtengo.
- Resistance Measurement (Ω):
Insert test leads as for voltage. Rotate the knob to the 'Ω' position. Connect the test leads across the component. The display will show the resistance value in Ohms (Ω).
- Kuyeza kwa Mphamvu:
Insert test leads as for voltage. Rotate the knob to the 'Ω' position and use the Function Selector button to cycle to capacitance mode (usually indicated by 'nF', 'µF'). Connect the test leads across the capacitor. The display will show the capacitance value.
- Mayeso a Diode:
Insert test leads as for voltage. Rotate the knob to the 'Ω' position and use the Function Selector button to cycle to diode test mode (indicated by a diode symbol). Connect the red lead to the anode and the black lead to the cathode of the diode. The display will show the forward voltage dontho.
- Kupitiliza Kuyesa:
Insert test leads as for voltage. Rotate the knob to the 'Ω' position and use the Function Selector button to cycle to continuity mode (indicated by a buzzer symbol). If the resistance is below a certain threshold, the buzzer will sound, indicating continuity.
- Zosagwirizana ndi Voltage (NCV) Kuzindikira:
Rotate the knob to the 'NCV' position. Bring the NCV sensor (top part of the clamp meter) close to an AC voltage source. The NCV light will illuminate, and an audible beep will sound, with increasing frequency as the meter gets closer to the voltagndi gwero.
- VFC (Variable Frequency Drive) Measurement:
Rotate the knob to the 'VFC' position. This mode is designed for measuring AC voltage and frequency of variable frequency drives, providing more stable readings in such environments.
- Frequency (Hz%) Measurement:
Rotate the knob to the 'Hz%' position. This mode measures the frequency of AC signals. Connect test leads as for voltage measurement. The display will show the frequency in Hertz (Hz).
Ntchito Zowonjezera
- HOLD Ntchito: Press the HOLD button (often combined with backlight) to freeze the current reading on the display. Press again to release.
- Kumbuyo: Press and hold the HOLD/Backlight button to activate the display backlight for better visibility in low-light conditions. Press and hold again to turn off.
- RMS yeniyeni: The CM2100 is a True RMS meter, meaning it accurately measures AC voltage and current for both sinusoidal and non-sinusoidal waveforms.
- Bluetooth Communication (CM2100B model only): If you have the CM2100B model, activate Bluetooth by pressing the BLE button. This allows remote data viewing and instrument control via a compatible smartphone application.

Chithunzi: Examples of the OWON CM2100 clamp meter in use, demonstrating capacitance measurement for maintenance, NCV (Non-Contact Voltage) inductive measurement, circuit board resistance measurement, and diode measurement.
Kusamalira
Kuyeretsa
Pukutani mita ndi malondaamp nsalu ndi sopo wofewa pang'ono. Musagwiritse ntchito mankhwala okwirira kapena zosungunulira. Sungani malo olowera opanda dothi ndi chinyezi.
Kusintha kwa Battery
When the low battery indicator appears on the display, replace the battery promptly to ensure accurate measurements. Refer to the "Battery Installation" section under Setup for instructions.
Kusungirako
If the meter is not used for an extended period, remove the battery to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
Kusaka zolakwika
| Vuto | Chifukwa Chotheka | Yankho |
|---|---|---|
| Chida choyezera sichikugwira ntchito. | Batire yakufa kapena yoyikidwa molakwika. | Check battery polarity or replace the battery. |
| Palibe kuwerenga kapena "OL" komwe kwawonetsedwa. | Overload, open circuit, or incorrect function selected. | Ensure the circuit is closed, select the correct function, or check if the measured value exceeds the meter's range. |
| Kuwerenga molakwika. | Low battery, poor test lead connection, or external interference. | Replace battery, ensure secure connections, move away from strong electromagnetic fields. |
| NCV not detecting voltage. | Weak signal, incorrect distance, or meter malfunction. | Ensure the sensor is close to the AC source. Test with a known live circuit. |
Zofotokozera
| Parameter | Mtengo |
|---|---|
| Mtundu | OWON |
| Chitsanzo | CM2100 (QD-CM2100) |
| Mtundu Woyezera | Ammeter, Voltmeter |
| Mawerengedwe Owonetsera | 20000 Chiwerengero |
| RMS yowona | Inde |
| AC / DC Pompano | Mpaka 100A |
| AC / DC Voltage | Mpaka 600V |
| AC Frequency Response | Mpaka 1000Hz |
| Zosagwirizana ndi Voltagndi (NCV) | Inde |
| Ntchito ya VFC | Inde |
| Kuyankhulana kwa Bluetooth | Available on CM2100B model |
| Mabatire | 1 Lithium Metal batri (yophatikizidwa) |
| Kulemera kwa chinthu | 0.5 Kilogram (1.1 pounds) |
| Makulidwe (L x W x H) | 9.84 x 5.91 x 7.09 mainchesi (25 x 15 x 18 masentimita pafupifupi.) |
| Zitsimikizo | CE, RoHS |
Chitsimikizo ndi Thandizo
OWON products are designed for reliability and performance. For warranty information or technical support, please refer to the official OWON webwebusayiti kapena funsani wofalitsa wakomweko. Sungani risiti yanu yogulira ngati umboni wa kugula kwa madandaulo a chitsimikizo.
Kuti mudziwe zambiri, mukhoza kupita ku OWON Store on Amazon.