This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Prity AM W12 wood-burning stove with an integrated boiler for central heating. Please read this manual thoroughly before using the appliance and retain it for future reference. The Prity AM W12 is designed to provide both room heating and hot water for your central heating system.

2. Malangizo a Chitetezo

Chitetezo chanu ndi cha ena n'chofunika kwambiri. Nthawi zonse tsatirani malangizo otsatirawa achitetezo:

  • Kuyika Kwaukatswiri: Installation must be performed by a qualified professional in accordance with all local and national building codes and regulations.
  • Zida Zoyaka: Maintain minimum clearances from combustible materials. As per EN 13240:2001/A2:2004/AC:2007, the minimum distances are:
    • Kumbuyo: 400 mm
    • Sides (left and right): 400 mm
    • Front (radiation from pane): 800 mm
    • Kutalika: 600 mm
  • Mtundu wa Mafuta: Only use dry wood with a moisture content of ≤20% or charcoal. Never use flammable liquids, plastics, or treated wood as fuel.
  • Malo Otentha: The stove's exterior surfaces become extremely hot during operation. Use appropriate protective gloves when handling and keep children and pets away.
  • Mpweya wabwino: Ensure adequate ventilation in the room where the stove is installed to prevent oxygen depletion.
  • Chimney/Flue: Regularly inspect and clean the chimney and flue pipe to prevent creosote buildup and ensure proper draft.
  • Mpweya wa Monoxide: Ikani chowunikira mpweya wa carbon monoxide pafupi ndi chitofu.
  • Dongosolo la Madzi: The integrated boiler must be connected to a closed central heating system by a qualified plumber. Ensure the system is properly filled and vented. The maximum working pressure is 1.25 bar.

This product complies with EN standard, CE certification, BlmSchV2, and ECO design regulations.

3. Kukhazikitsa ndi Kuyika

The Prity AM W12 is designed for corner placement and built-in installation. Proper setup is crucial for safety and performance.

3.1 Kutsegula ndi Kuyendera

Carefully unpack the stove and inspect it for any damage that may have occurred during transit. Report any damage to your supplier immediately.

3.2 Kuyika

Position the stove in the desired corner, ensuring it meets the minimum clearance requirements from combustible materials as detailed in the Safety Instructions section.

Prity AM W12 wood-burning stove installed in a corner with a fire burning inside.

Image 3.2.1: The Prity AM W12 stove installed in a corner setting, demonstrating typical placement.

3.3 Kulumikizana kwa Chitoliro cha Flue

Connect the stove to a suitable chimney or flue system. The flue pipe diameter required is 150 mm. Ensure all connections are sealed properly to prevent smoke leakage and ensure optimal draft.

3.4 Central Heating System Connection

The integrated water boiler requires connection to your central heating system. This must be done by a certified plumber. The boiler has a volume of 7 liters and is designed to operate at a maximum working pressure of 1.25 bar. Ensure the system is properly filled, vented, and tested for leaks before initial firing.

Mbali view of the Prity AM W12 wood-burning stove, showing the flue pipe connection point at the top.

Chithunzi 3.4.1: Mbali view of the Prity AM W12 stove, highlighting the flue outlet and overall construction.

4. Malangizo Ogwiritsira Ntchito

Follow these steps for safe and efficient operation of your Prity AM W12 stove.

4.1 Fueling the Stove

Open the main combustion chamber door using the wooden handle. Place a small amount of kindling and firelighters on the cast iron grate. Once ignited, gradually add small pieces of dry wood or charcoal. Do not overfill the combustion chamber.

Prity AM W12 wood-burning stove with a vibrant fire burning inside the combustion chamber.

Image 4.1.1: The Prity AM W12 stove in operation, showing a fire burning within the heat-resistant ceramic glass window.

Prity AM W12 wood-burning stove with the combustion chamber door closed, showing the empty interior and cast iron grate.

Image 4.1.2: The Prity AM W12 stove with the combustion chamber empty, illustrating the interior design and cast iron grate.

4.2 Air Supply Control

The stove is equipped with a front damper for regulating the air supply to the combustion chamber. Open the damper fully during ignition to establish a strong fire. Once the fire is established, adjust the damper to control the burn rate and heat output. A fully open damper provides more air, leading to a hotter, faster burn. A partially closed damper reduces air, resulting in a slower, more efficient burn.

4.3 Flame Intensity Adjustment

Kusuta damper is provided to adjust the flame intensity. This allows for fine-tuning of the combustion process and heat distribution.

4.4 Kuwonjezera mafuta

When adding more fuel, open the air damper fully for a few minutes before opening the combustion chamber door. This helps to prevent smoke from entering the room. Add fuel carefully and close the door securely.

5. Kusamalira

Regular maintenance ensures the longevity and efficient operation of your Prity AM W12 stove.

5.1 Kuchotsa Phulusa

Regularly remove ash from the ash pan located below the combustion chamber. Ensure the stove is completely cool before performing this task. Dispose of ash in a non-combustible container.

5.2 Cleaning the Combustion Chamber

Periodically clean the interior of the combustion chamber, including the heat-resistant ceramic glass. Use a soft brush or vacuum cleaner for ash and a specialized glass cleaner for stove glass. Do not use abrasive cleaners.

5.3 Flue Pipe and Chimney Cleaning

The flue pipe and chimney should be inspected and cleaned at least once a year, or more frequently depending on usage. This prevents creosote buildup, which can lead to chimney fires and reduced efficiency. This task should be performed by a qualified chimney sweep.

5.4 Boiler System Check

Regularly check the pressure in your central heating system and ensure it is within the recommended operating range. Inspect all connections for leaks. Consult a qualified plumber for any issues with the boiler system.

6. Mavuto

This section addresses common issues you might encounter with your Prity AM W12 stove. For complex problems, consult a qualified technician.

  • Poor Draft / Smoke in Room:
    • Check if the flue pipe or chimney is blocked and requires cleaning.
    • Ensure the air dampers are open sufficiently.
    • Verify that the chimney height and diameter are adequate for the stove.
    • Check for negative pressure in the room (e.g., due to extractor fans).
  • Kutulutsa Kutentha Kwambiri:
    • Ensure you are using dry, seasoned wood. Wet wood burns inefficiently.
    • Check if the air dampers are open enough.
    • Verify that the combustion chamber and ash pan are clean.
  • Excessive Fuel Consumption:
    • Sinthani mpweya dampers to reduce the burn rate.
    • Ensure the stove door seals are intact and not allowing excess air.
  • Water System Not Heating:
    • Check the central heating system pressure.
    • Ensure the boiler is receiving sufficient heat from the combustion.
    • Bleed the radiators and the boiler system to remove any airlocks.
    • Consult a qualified plumber if the issue persists.

7. Zofotokozera

Detailed technical specifications for the Prity AM W12 wood-burning stove with boiler:

Table showing product information and technical specifications for Prity AM W12 stove.

Image 7.1.1: Product Information table for Prity AM W12, detailing various technical specifications.

MbaliKufotokozera
Nambala ya ModelAM W12
Total Dimensions (W x D x H)720 x 550 x 820 mm
Combustion Chamber Dimensions (W x D x H)635 x 450 x 315 mm
Kalemeredwe kake konse113kg pa
Nominal Room Heating Output6.2 kw pa
Nominal Water Heating Output7.3 kw pa
Maximum Water Heating Output12 kw pa
Flue Pipe Diameter150 mm
Kuchita bwino76.5%
Volume of Water Heater7 L
Estimated Heating Area105 m²
Estimated Heating Capacity277 m³
Zofunika Zathupi2 mm thick sheet steel
Zapamwamba3-4 mm thick sheet steel
Mtundu wa MafutaWood, Charcoal (Dry wood with moisture content ≤20%)
Maximum Working Pressure1.25 bwalo
Flue Gas Temperature at Nominal Heat Output180 °C
Minimum Chimney Draft11.4 pa
Kugwiritsa Ntchito Mafuta4.3kg/h
Kugwirizana kwa Fittings3/4"
Kalasi Yogwiritsa Ntchito MphamvuA
Mlozera Wamphamvu Mwachangu (EEI)102
Kugwira Ntchito Mwachangu kwa Mlengalenga (ηs)68%
MtunduZojambula Pazithunzi
Zigawo ZophatikizidwaCast iron grate, Wooden door handles
Energy efficiency label for Prity AMW12 stove, showing an A rating and heat output values.

Image 7.1.2: Energy Label for Prity AMW12, indicating an A-class energy efficiency rating.

German Declaration of Performance for Prity AMW12, detailing compliance with standards and technical data.

Image 7.1.3: German Declaration of Performance for Prity AMW12, showing compliance and performance data.

English Declaration of Performance for Prity AMW12, detailing compliance with standards and technical data.

Image 7.1.4: English Declaration of Performance for Prity AMW12, providing essential performance characteristics.

EAN/Barcode: 3800215095054

8. Chitsimikizo ndi Thandizo

For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. In case of technical issues or questions not covered in this manual, please contact Prity customer support or your authorized service provider.

Zolemba Zofananira - AM W12

Preview Prity Boilers: Technical Description, Installation, and Operation Manual
Comprehensive guide for Prity residential boilers, covering technical specifications, installation procedures, operation instructions, maintenance, and troubleshooting for solid fuel and pellet models.
Preview W12 Wireless Portable Charger User Manual
User manual for the W12 Wireless Portable Charger by Guangdong Gadmei Intelligent Technology Co., LTD. Learn about product features, specifications, charging methods, safety precautions, and troubleshooting.
Preview SANSUI W12 Bluetooth Headset - Specifications and FCC Compliance
Official information for the SANSUI W12 Bluetooth Headset, including technical specifications and FCC compliance statements.
Preview Joyroom JR-W12 Foldable Wireless Watch Charger User Manual
User manual for the Joyroom JR-W12 Foldable Wireless Watch Charger, detailing its specifications, operation, and safety warnings. Includes information on product introduction, operation steps, function description, and compliance with EU directives.
Preview Redkey W12 Pro 4-in-1 Multi-Functional Floor Washer Malangizo Buku
Buku lachilangizo la Redkey W12 Pro 4-in-1 Multi-Functional Floor Washer, lophimba chitetezo, kusonkhana, kugwira ntchito, kukonza, ndi kuthetsa mavuto.