1. Mawu Oyamba
This user manual provides detailed instructions for the installation, operation, and maintenance of the POTTER 12/24 VDC 4-Wire Strobe Light, Model SL 5A C. This device is designed to provide visual signaling in various applications, particularly in fire safety and alarm systems. Please read this manual thoroughly before installation and operation to ensure proper function and safety.
2. Zambiri Zachitetezo
Nthawi zonse tsatirani ma code ndi malamulo apafupi mukayika ndi kugwiritsa ntchito chipangizochi. Kulephera kuchita zimenezi kungawononge katundu, kuvulazidwa, kapena imfa.
- Disconnect all power sources before installation, maintenance, or servicing.
- Kuyika kuyenera kuchitidwa ndi anthu oyenerera.
- Ensure proper wiring polarity and voltage (12/24 VDC) to prevent damage to the unit.
- Do not expose the device to excessive moisture or extreme temperatures outside its specified operating range.
- Yang'anani nthawi zonse chipangizochi kuti muwone ngati chikuwonongeka kapena chawonongeka.
3. Zamalonda Zathaview
The POTTER SL 5A C is a robust 12/24 VDC 4-wire cylindrical strobe light designed for clear visual signaling. It features a durable metal construction with a powder-coated finish and utilizes a Light Emitting Diode (LED) as its light source. Available in clear, red, orange, and yellow lens options.
3.1. Zigawo
- Strobe Light Unit (Cylindrical Housing)
- Ogwiritsa Base
- Wiring Terminals (4-wire connection)
- Lens (Clear, Red, Orange, or Yellow)
3.2. Image Image

Image: A visual representation of four POTTER cylindrical strobe lights. From left to right, the lights are shown with orange, blue, clear, and red lenses. Each unit consists of a black base and a ribbed, translucent cylindrical lens, illustrating the design and color variations of the product line.
4. Kukhazikitsa ndi Kuyika
Follow these steps for proper installation of the POTTER SL 5A C strobe light:
- Kuyimitsa Mphamvu: Ensure all power to the installation area is disconnected at the circuit breaker or fuse box before beginning any wiring.
- Malo Oyikira: Select a suitable mounting location that is stable, dry, and provides clear visibility for the strobe light. The device is designed for surface mounting.
- Kuyika Base: Secure the mounting base to the chosen surface using appropriate fasteners (not included). Ensure the base is firmly attached.
- Wiring: Connect the 4-wire power source to the terminals on the strobe light unit. Pay close attention to polarity (positive and negative) and ensure connections are secure. Refer to the wiring diagram provided with the product packaging for specific terminal assignments.
- Attach Strobe Unit: Once wiring is complete and verified, carefully attach the strobe light unit to its mounted base. Ensure it clicks or locks securely into place.
- Kubwezeretsa Mphamvu: Restore power to the circuit and test the strobe light for proper operation.
5. Malangizo Ogwiritsira Ntchito
The POTTER SL 5A C strobe light operates automatically when power is supplied to its 4-wire connection. It is designed to provide a continuous visual strobe signal when activated by the connected alarm or control panel.
- Kutsegula: The strobe light will activate and begin flashing when the appropriate 12/24 VDC power is applied to its input terminals.
- Kuletsa: The strobe light will cease flashing when the power supply is removed.
- Kuyesa: Regular testing of the strobe light, in accordance with local fire safety regulations and system requirements, is recommended to ensure proper functionality.
6. Kusamalira
The POTTER SL 5A C strobe light requires minimal maintenance. Regular inspection and cleaning will help ensure its longevity and reliable operation.
- Kuyeretsa: Periodically clean the lens and exterior housing with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these may damage the finish or lens.
- Kuyendera: Annually inspect the wiring connections for tightness and signs of corrosion. Check the mounting for security.
- Kuyesa Kachitidwe: Perform regular functional tests as part of your overall fire alarm or security system maintenance schedule.
7. Mavuto
If the strobe light is not functioning as expected, refer to the following table for common issues and solutions:
| Vuto | Chifukwa Chotheka | Yankho |
|---|---|---|
| Strobe light does not flash. | Palibe magetsi. Incorrect wiring/polarity. Chigawo cholakwika. | Verify power is supplied to the unit. Check all wiring connections for correctness and tightness, ensuring correct polarity. Ngati magetsi ndi mawaya zili bwino, chipangizocho chingakhale ndi vuto ndipo chingafunike kusinthidwa. |
| Strobe light flashes intermittently. | Kulumikizana kwa waya wotayirira. Mphamvu zosakwanira. | Yang'anani ndi kumangitsa ma waya onse. Ensure the power supply is stable and within the 12/24 VDC range. |
| Kutulutsa kwa kuwala ndikocheperako. | Lens yakuda. Kutsika voltage. | Tsukani mandala ndi chofewa, damp nsalu. Tsimikizirani voltage is within the specified range (12/24 VDC). |
8. Zofotokozera
| Mbali | Tsatanetsatane |
|---|---|
| Nambala ya Model | SL 5A C |
| Gawo Nambala | PSL5AC |
| UPC | 742779300874 |
| Voltage | 12/24 VDC |
| Wiring | Kulumikiza kwa 4-Waya |
| Mtundu Wowala | Light Emitting Diode (LED) |
| Zosankha zamtundu | Clear, Red, Orange, Yellow (lens) |
| Maonekedwe | Cylindrical |
| Zakuthupi | Chitsulo |
| Tsitsani Mtundu | Powder Wokutidwa |
| Mtundu Wokwera | Surface Mount |
| Wopanga | WOWAMBIRA |
9. Chitsimikizo ndi Thandizo
For information regarding the product warranty, please refer to the warranty card included with your purchase or visit the official POTTER website. For technical support, troubleshooting assistance beyond this manual, or replacement parts, please contact POTTER customer service through their official channels.
Note: Unauthorized modifications or repairs may void the product warranty.