APEX Domus 3

Buku Logwiritsira Ntchito la Apex Medical Domus 3 Alternating Pressure Mattress System

Model: Domus 3

1. Mawu Oyamba

This manual provides comprehensive instructions for the safe and effective use of the Apex Medical Domus 3 Alternating Pressure Mattress System. This system is designed to assist in the prevention and treatment of pressure injuries, ulcers, and bedsores for individuals requiring extended bed rest. Please read this manual thoroughly before setup and operation.

Apex Medical Domus 3 Alternating Pressure Mattress System with pump on a hospital bed.

Chithunzi 1.1: The Apex Medical Domus 3 Alternating Pressure Mattress System. This image displays the complete system, including the mattress installed on a hospital bed frame and the external pump unit. The mattress features individual air cells, and the pump is shown connected to the mattress.

2. Zambiri Zachitetezo

Adherence to the following safety guidelines is crucial for patient well-being and proper system function.

3. Zigawo

The Apex Medical Domus 3 system typically includes the following components:

4. Malangizo Kukhazikitsa

  1. Konzani Pakhomo la Bedi: Place the mattress system directly onto a standard hospital or home bed frame. Ensure the bed frame is clean and free of sharp objects that could damage the mattress.
  2. Ikani matiresi: Unroll the Domus 3 mattress on the bed frame with the air hose connection end positioned towards the foot of the bed where the pump will be placed. Ensure the CPR strap is accessible.
  3. Gwirizanitsani Pampu: Attach the air hoses from the mattress to the corresponding connectors on the variable pressure pump unit. Ensure connections are secure.
  4. Mount the Pump: Hang the pump unit securely at the foot of the bed using its integrated hangers.
  5. Lumikizani Mphamvu: Plug the pump's power cord into a grounded electrical outlet.
  6. Kukwera Mtengo Koyamba: Turn on the pump. The mattress will begin to inflate. Allow approximately 20-30 minutes for the mattress to fully inflate and stabilize before placing a patient on it.
Apex Medical Domus 3 mattress cover with zipper and water-resistant material detail.

Chithunzi 4.1: Mattress Cover Features. An image showcasing two features of the mattress cover: a close-up of the zipper-all-around design for easy removal and replacement, and a magnified view of the Nylon/PU cover material demonstrating its water-resistant properties with water droplets on the surface.

5. Malangizo Ogwiritsira Ntchito

5.1 Kuyatsa/Kuzimitsa

5.2 Njira Zochiritsira

The Domus 3 offers two therapy modes:

Refer to the pump unit's controls to select the desired therapy mode.

Diagram illustrating the alternating pressure redistribution cycle of the mattress.

Chithunzi 5.1: Alternating Pressure Cycle. This diagram shows a human figure lying on the mattress, with an illustration of the alternating pressure cycle. Blue blocks represent inflated air cells, and arrows indicate the cyclical inflation and deflation pattern designed to redistribute pressure and prevent injury.

5.3 Pressure Adjustment (Firmness)

The pump unit features a variable pressure setting with a weight indicator.

5.4 Low Air Loss Function

Air cells 3 through 11 are designed with a low air loss feature. This function continuously ventilates air to wick moisture and heat away from the mattress surface, contributing to patient comfort and skin integrity. This operates automatically when the system is powered on.

Close-up of Apex Medical Domus 3 mattress showing low air loss ventilation.

Chithunzi 5.2: Low Air Loss Feature. A detailed view of the mattress surface, highlighting the low air loss feature. Blue arrows indicate airflow through the air cells, designed to reduce moisture and heat for patient comfort and prevent skin maceration.

6. Kusamalira ndi Kusamalira

6.1 Cleaning the Mattress and Cover

6.2 Air Cell Replacement

Each of the 20 individual 8-inch air cells can be removed and replaced if damaged.

  1. Turn off the pump and disconnect it from the mattress.
  2. Unzip the mattress cover.
  3. Carefully detach the damaged air cell from its connections within the mattress structure.
  4. Install a new, compatible air cell, ensuring it is securely connected.
  5. Zip the mattress cover back into place and re-connect the pump for inflation.

7. Mavuto

VutoChifukwa ChothekaYankho
Mattress not inflating or losing pressure
  • Chingwe chamagetsi chachotsedwa
  • Air hoses not securely connected
  • Leak in mattress or air cells
  • Kuwonongeka kwa pampu
  • Check power connection to outlet and pump.
  • Ensure air hoses are firmly attached to both mattress and pump.
  • Inspect mattress and individual air cells for punctures or damage. Replace damaged cells if necessary.
  • Contact customer support if pump appears to be malfunctioning.
Low pressure alarm sounds
  • Mattress not fully inflated
  • Kutuluka kwa mpweya
  • Patient weight exceeds capacity
  • Allow more time for inflation.
  • Check for leaks in mattress or hose connections.
  • Verify patient weight is within the 440 lbs capacity.
Pump is unusually loud
  • Obstruction around pump fan
  • Kuwonongeka kwa pampu
  • Ensure adequate ventilation around the pump unit.
  • Contact customer support if noise persists. (Note: Pump noise level is typically ≤ 30dB(A)).

8. Zofotokozera

MbaliTsatanetsatane
ChitsanzoNyumba 3
Mattress Dimensions (L x W x H)78.7 x 35.4 x 8 mainchesi
Kulemera kwadongosoloPafupifupi 22.3 mapaundi
Kulemera Kwambiri440 mapaundi
Mtundu wa NsaluNylon, Polyurethane (Cover)
ZapaderaLow Air Loss, Alternating Pressure, Water Resistant Cover, CPR Strap, Low Pressure Alarm
Pump Noise Level≤ 30dB(A)
WopangaPamwamba Medical
Dimensions of Apex Medical Domus 3 mattress and pump system.

Chithunzi 8.1: System Dimensions. A visual representation of the dimensions for both the Apex Medical Domus 3 mattress and its accompanying pump unit. Key measurements for length, width, and height are indicated for both components.

Apex Medical Domus mattress showing two height options, 5-inch and 8-inch.

Chithunzi 8.2: Mattress Height Options. This image illustrates the two available height options for the Domus mattress: a 5-inch version and an 8-inch version. The current product is the 8-inch model, providing enhanced support.

9. Chitsimikizo ndi Thandizo

9.1 Chidziwitso cha Chitsimikizo

The Apex Medical Domus 3 Alternating Pressure Mattress System comes with a 1-year chitsimikizo on both the mattress and the pump unit. This warranty covers manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims.

9.2 Thandizo la Makasitomala

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Apex Medical customer support. Refer to the product packaging or the official Apex Medical webwebusayiti kuti mudziwe zambiri.

Zolemba Zofananira - Nyumba 3

Preview APEX XT Auto Provider Mode Quick Guide
A quick guide for medical professionals on how to use the APEX XT Auto device in Provider Mode, including setup navigation and resetting compliance meters.
Preview APEX VAC Pump User Manual: Malangizo ndi Chitetezo
Buku lathunthu la ogwiritsa ntchito la APEX VAC Pump, tsatanetsatane wa magwiridwe antchito, chitetezo, ukadaulo, ndi kuthetsa mavuto amitundu ya VacPro, VacMaxi, ndi VacPlus kuchokera ku Apex Medical Corp.
Preview APEX XT Auto CPAP System Instruction Manual
Buku la malangizo lathunthu la APEX XT Auto CPAP System (Model 9S-005720), kufotokoza mwatsatanetsatane kukhazikitsidwa, kugwira ntchito, kukonza, kuthetsa mavuto, ndi ukadaulo wochizira Obstructive Sleep Apnea (OSA).
Preview Buku Lophunzitsira la Mpando Wopaka Massage wa APEX-V2 - Malangizo Okhazikitsa, Kugwiritsa Ntchito, ndi Kukonza
Buku lophunzitsira lathunthu la mpando wopaka masaji wa APEX-V2, lomwe limafotokoza njira zodzitetezera, kukhazikitsa, kugwiritsa ntchito, makonda, zofunikira, kuthetsa mavuto, kuyeretsa, ndi kukonza. Phunzirani momwe mungakhazikitsire ndikugwiritsa ntchito bwino mpando wanu wopaka masaji wa APEX-V2.
Preview Buku la Mwini wa Dongosolo la Chitetezo la DESTINY
Buku la eni ake la Apex DESTINY Security System limapereka malangizo athunthu okhudza kukhazikitsa, kugwiritsa ntchito, njira zodzitetezera (KUTALI, KUNYUMBA, USIKU), njira zolowera kutali, ntchito zodutsa, ndi zinthu zina zomwe mungasankhe zodzitetezera kunyumba.
Preview Buku Logwiritsira Ntchito Mpando Wopaka Massage wa Apex AP-Pomp
Buku lothandizira ogwiritsa ntchito la mpando wa massage wa Apex AP-Pomp, lomwe limafotokoza za chitetezo, kukonza, kukhazikitsa, ntchito zowongolera, kuthetsa mavuto, ndi zofunikira.