1. Mawu Oyamba
This manual provides essential information for the proper installation, operation, and maintenance of your Klimaire KSIR036H218 3 Ton Light Commercial Floor/Ceiling Inverter Heat Pump System. Please read this manual thoroughly before using the unit and retain it for future reference. Proper understanding and adherence to these instructions will ensure optimal performance and longevity of your system.
2. Zambiri Zachitetezo
Important: Installation and service of this equipment must be performed by a licensed HVAC technician. Improper installation or service can result in electric shock, fire, property damage, personal injury, or death.
- Nthawi zonse thimitsani magetsi ku yuniti musanakonze kapena kukonza chilichonse.
- Onetsetsani malo oyenera kuti musagwedezeke ndi magetsi.
- Osayesa kukonza kapena kusintha gawolo nokha. Lumikizanani ndi katswiri wodziwa ntchito.
- Sungani ana ndi ziweto kutali ndi chipinda chakunja.
- Ensure adequate ventilation around the outdoor unit.
3. Zamalonda Zathaview
The Klimaire KSIR036H218 is a versatile 3-ton light commercial inverter heat pump system designed for efficient heating and cooling in various commercial environments. Its flexible design allows for floor, low-wall, or ceiling suspension mounting.
Zofunika Kwambiri
- Inverter technology for energy efficiency and precise temperature control.
- Extremely quiet operation, suitable for heavy traffic and public areas.
- Flexible installation: ceiling, low wall, or floor mounting.
- Includes a wireless remote control for convenient operation.
- Multiple operating modes: Cooling, Heating, Fan, and Dehumidification.
- Advanced functions: 24-hour timer, sleep mode, auto restart, refrigerant leak detection.
- 3D airflow with auto swing louvers for even air distribution.
- Built-in base pan heater for reliable operation down to 5°F.
- Washable, reusable air filter for easy maintenance.
Zigawo Zophatikizidwa
- Indoor Floor/Ceiling Unit
- Panja Condenser Unit
- Wireless Remote Control
- Wall bulaketi
- 15-ft Installation Kit (refrigerant piping, electrical wiring, drain hose, insulation)
Zowoneka Zamalonda




4. Kukhazikitsa ndi Kuyika
Warning: This system requires professional installation by a licensed HVAC technician. Attempting to install this unit without proper qualifications can void the warranty and lead to serious hazards.
- Kusankha Kwatsamba: Choose an installation location that allows for proper airflow, drainage, and maintenance access for both indoor and outdoor units.
- Kuyika Unit mkati: The indoor unit can be mounted on the ceiling, low on a wall, or directly on the floor. Ensure the mounting surface is strong enough to support the unit's weight.
- Malo Ogulitsira Zinthu Panja: The outdoor condenser is pre-charged with refrigerant for up to 25 feet of piping. It can be placed on a level ground surface or mounted to a wall using the provided wall brackets.
- Refrigerant Piping: Connect the pre-charged outdoor unit to the pre-vacuumed indoor unit using the provided installation kit. Ensure all connections are leak-free.
- Zolumikizira zamagetsi: Connect the unit to a dedicated power supply according to local electrical codes. The system operates on 208-230V.
- Ngalande: Install the drain hose to ensure proper condensation removal from the indoor unit.
5. Malangizo Ogwiritsira Ntchito
Your Klimaire heat pump system is controlled via the included wireless remote control. Familiarize yourself with the remote's functions for optimal use.

Ntchito Zakutali
- ON/WOZIMA Batani: Imayatsa kapena kuyimitsa chipangizocho.
- Batani la MODE: Cycles through operating modes: Auto, Cool, Heat, Fan, Dry (Dehumidification).
- TEMP Buttons (Up/Down): Imasintha kutentha komwe mukufuna.
- Batani la FAN: Imasankha liwiro la fan (Yokha, Yotsika, Yapakatikati, Yapamwamba).
- SWING Batani: Activates or deactivates the automatic louver swing for even air distribution.
- NTHAWI YOYATSA/YOZImitsa: Sets the automatic on/off times for the unit.
- KUGWIRA NTCHITO: Adjusts temperature settings automatically during sleep for comfort and energy saving.
- TURBO Mode: Provides rapid cooling or heating for a short period.
Njira Zogwirira Ntchito
- Kuzizira: Provides cooling to maintain the set temperature.
- Kutentha: Provides heating to maintain the set temperature, effective down to 5°F ambient temperature.
- Mafilimu angaphunzitse: Imazungulira mpweya popanda kutentha kapena kuziziritsa.
- Dry (Dehumidification) Mode: Amachepetsa chinyezi m'chipinda.
- Auto mumalowedwe: The unit automatically selects the appropriate mode (Cool, Heat, or Fan) based on the room temperature and your set temperature.
Kuyambiranso: In case of a power interruption, the unit will automatically restart with the previous settings once power is restored.
6. Kusamalira
Regular maintenance ensures efficient operation and extends the lifespan of your heat pump system. Always disconnect power before performing maintenance.
- Kuyeretsa Zosefera: The indoor unit features a washable, reusable air filter. Clean the filter every 2-4 weeks, or more frequently depending on usage and air quality. Remove the filter, wash it with mild detergent and water, rinse thoroughly, and allow it to dry completely before reinserting.
- Indoor Unit Cleaning: Wipe the exterior of the indoor unit with a soft, damp nsalu. Osagwiritsa ntchito mankhwala ankhanza kapena zotsukira abrasive.
- Kuyeretsa Zipangizo Zakunja: Periodically clear any debris (leaves, dirt) from around the outdoor condenser unit. Ensure the coils are clean and free of obstructions. A garden hose can be used to gently rinse the coils.
- Kuyendera akatswiri: It is recommended to have a licensed HVAC technician perform an annual inspection and professional cleaning to ensure all components are functioning correctly and to check refrigerant levels.
7. Mavuto
Musanayambe kulankhulana ndi utumiki, review the following common issues and solutions. If the problem persists, contact a licensed HVAC technician.
| Vuto | Chifukwa Chotheka | Yankho |
|---|---|---|
| Chigawo sichiyatsa | No power supply; Remote control batteries low; Circuit breaker tripped | Check power connection; Replace remote batteries; Reset circuit breaker |
| Kuzizira kosakwanira/kutenthetsa | Dirty air filter; Blocked outdoor unit; Incorrect mode setting; Low refrigerant | Clean air filter; Clear obstructions from outdoor unit; Select correct mode; Contact technician for refrigerant check |
| Phokoso lachilendo | Loose parts; Fan obstruction; Refrigerant flow noise (normal) | Check for loose panels; Clear obstructions; Consult technician if noise is excessive or unusual |
| Kutuluka kwa madzi kuchokera m'chipinda chamkati | Clogged drain hose; Improper installation | Check and clear drain hose; Contact technician for inspection |
8. Mafotokozedwe aukadaulo
Below are the key technical specifications for the Klimaire KSIR036H218 system.
| Kufotokozera | Mtengo |
|---|---|
| Mtundu | Klimaire |
| Nambala ya Model | KSIR036H218 |
| Mphamvu | 3 Tons (36,000 BTU) |
| Seasonal Energy Efficiency Ratio (SEER) | 16.00 |
| Heating Seasonal Performance Factor (HSPF) | 10.00-10.50 |
| Voltage | 230 volts |
| Noise Level (Outdoor Unit) | 54 decibels |
| Mtundu Woyika | Split System (Floor/Ceiling) |
| Zapadera | 5°F Low ambient Heating and Cooling operation, Adjustable airflow with wireless LED remote, Auto restart after power failure, Auto swing louvers, Timer Option |
| Kuphatikiza Zida | Indoor Floor/Ceiling Unit, Outdoor Condenser, Wall Bracket, 15-ft Installation Kit |

9. Chitsimikizo ndi Thandizo
Your Klimaire heat pump system is backed by a manufacturer's warranty.
- Chitsimikizo cha Compressor: The system includes a 5-Year Compressor Manufacturer Warranty.
- General Support: For warranty claims, technical assistance, or service inquiries, please contact Klimaire customer support or an authorized Klimaire service center. Ensure you have your model number (KSIR036H218) and proof of purchase available.
- Professional Service: All service and repairs should be conducted by a licensed HVAC professional to maintain warranty validity and ensure safe operation.