Mawu Oyamba

This manual provides essential information for the installation, operation, and maintenance of your Lunos e² decentralized ventilation system. Please read this manual thoroughly before installation and operation to ensure proper function and safety. Keep this manual for future reference.

The Lunos e² system is a highly efficient, decentralized ventilation unit with heat recovery, designed for room-by-room ventilation. It operates on a reversible airflow principle using a ceramic regenerator, ensuring low energy consumption and quiet operation.

Zida Zopangira

Zaphulika view of Lunos e² ventilation unit components and accessories

Chithunzi 1: Zaphulika view of the Lunos e² decentralized ventilation units and accompanying accessories. This image shows two complete ventilation units, two round ducts, a universal control unit, a power supply, and a wall switch. Each ventilation unit consists of an outer grille, a fan, a ceramic heat exchanger, and an inner panel with a filter.

The Lunos e² system includes:

Kukhazikitsa ndi Kuyika

Installation should be performed by a qualified professional. Ensure all local building codes and regulations are followed.

Macheke oyikatu:

Masitepe oyika:

  1. Drill a 162 mm diameter hole through the wall at the desired location, ensuring a slight downward slope to the outside for drainage.
  2. Insert the round duct (DN160 mm) into the drilled hole. Cut the duct to the appropriate length for the wall thickness.
  3. Install the Lunos e² ventilation unit into the duct. Ensure the ceramic heat exchanger and fan are correctly oriented.
  4. Mount the exterior grille (1-WE 180) on the outside of the wall, securing it with screws.
  5. Mount the interior panel with filter (9/IBE) on the inside of the wall.
  6. Connect the ventilation units to the 5/UNI-FT universal control unit.
  7. Connect the 5/NT18 power supply to the universal control unit and to the main power.
  8. Install the 5/W2U switch in a convenient location and connect it to the universal control unit.

Malangizo Ogwiritsira Ntchito

The Lunos e² system is designed for continuous operation to maintain optimal indoor air quality and heat recovery.

Ntchito Yoyambira:

Njira Zogwirira Ntchito:

The Lunos e² system typically offers multiple fan speed settings to adjust ventilation rates:

The system also features humidity recovery, typically around 20-30%, to prevent excessive drying of indoor air during colder months.

Kusamalira

Regular maintenance ensures optimal performance and longevity of your Lunos e² ventilation system.

Kusintha/Kuyeretsa Sefa:

The G3 filter should be checked regularly and replaced or cleaned as needed, typically every 3-6 months depending on air quality.

  1. Turn off the ventilation system at the main switch.
  2. Carefully remove the interior panel.
  3. Remove the G3 filter.
  4. Clean the filter by vacuuming or gently washing with warm water (if washable type). Allow to dry completely before reinstallation. Replace if heavily soiled or damaged.
  5. Reinsert the clean/new filter and reattach the interior panel.
  6. Turn the system back on.

Ceramic Heat Exchanger Cleaning:

The ceramic heat exchanger should be cleaned annually or if performance degrades.

  1. Turn off the ventilation system.
  2. Remove the interior panel and filter.
  3. Carefully pull out the ceramic heat exchanger unit.
  4. Clean the ceramic core under running water. Do not use harsh detergents. Allow to dry completely.
  5. Reinsert the dry ceramic heat exchanger, ensuring correct orientation.
  6. Reinstall the filter and interior panel.
  7. Turn the system back on.

Exterior Grille Cleaning:

Periodically inspect and clean the exterior grille to ensure unobstructed airflow.

Kusaka zolakwika

If you experience issues with your Lunos e² system, consult the following table before contacting support.

VutoChifukwa ChothekaYankho
System not operatingNo power supply; switch is OFF.Check power connection; ensure switch is ON. Verify power supply (5/NT18) is functioning.
Reduced airflow or efficiencyClogged filter; dirty ceramic heat exchanger; obstructed exterior grille.Clean or replace filter; clean ceramic heat exchanger; clear any obstructions from the exterior grille.
Phokoso losazolowerekaFan obstruction; loose components.Turn off system and inspect fan for obstructions. Ensure all components are securely installed. If noise persists, contact support.
Condensation around unitImproper installation (e.g., no downward slope); extreme temperature difference.Ensure proper installation with slight downward slope. If problem persists, consult a professional.

Zofotokozera

Detailed technical specifications for the Lunos e² decentralized ventilation system.

Lunos e² Energy Label

Chithunzi 2: Energy label for the Lunos e² ventilation system, indicating an A+ energy efficiency rating, 40 dB sound level, and a maximum airflow of 38 m³/h.

Lunos e² Product Data Sheet

Chithunzi 3: Product data sheet for the Lunos e² ventilation system, detailing specifications such as supplier, model identification, specific energy consumption, type of heat recovery, thermal efficiency, maximum flow rate, power input, sound pressure level, and annual energy consumption.

ParameterMtengo
ChitsanzoLunos e²
Kubwezeretsa Kutentha Mwachangu90.6%
Airflow Volume (m³/h)18/31/38
Power Consumption per unit (W)1.4/2.8/3.3
Rated Power (W/m³/h)0.09
Network Voltage12V DC
Humidity RecoveryApprox. 20-30%
Mulingo wa Pressure Level (dB)16.5/19.5/26
Normal Sound Level (DN,W, open)42db pa
Kutalika kwa Unit243 mm
Minimum Wall Thickness300 mm
Hole Diameter162 mm

Chitsimikizo ndi Thandizo

For warranty information, please refer to the documentation provided with your purchase or contact Lunos directly. Keep your proof of purchase for warranty claims.

For technical support, spare parts, or further assistance, please contact Lunos customer service. Contact details can typically be found on the manufacturer's official webtsamba lanu kapena pa invoice yanu yogulira.

Wopanga: Lunos

Webtsamba: www.lunos.de

Zolemba Zofananira - localization_B07MQ62LLD

Preview Buku Lokhazikitsa Makina Opumira Opanda Mphamvu a LUNOS Nexxt
Buku lothandizira kukhazikitsa makina opumira a LUNOS Nexxt omwe ali ndi njira yochepetsera kutentha, kuphatikizapo zofunikira paukadaulo, kuyika, kulumikizana kwa magetsi, makonda a switch ya DIP, kusintha zosefera, ndi kukonza.
Preview LUNOS e² Series Decentralised Ventilation System Installation Manual
Installation manual for the LUNOS e² Series decentralized ventilation system with heat recovery. Includes technical specifications, electrical connection diagrams, and installation guidelines.
Preview LUNOS Series e² Decentralized Ventilation System yokhala ndi Kubwezeretsa Kutentha - Buku Loyika
Buku lathunthu unsembe wa LUNOS Series e² decentralized mpweya mpweya ndi kuchira kutentha. Imakhala ndi zambiri zamalonda, ukadaulo, kulumikizana ndi magetsi, malangizo oyika, ndi kukonza mamodelo monga e², e²kurz, e²60, ndi e²60kurz.
Preview LUNOS 5/UNI-FT & 5/UNI-RF Universal Control Installation Manual
Installation manual for the LUNOS 5/UNI-FT and 5/UNI-RF Universal Control system, detailing features, technical specifications, electrical connections, coding switch settings, and operational modes for ventilation systems.
Preview LUNOS Ventilation System Commissioning Protocol
A detailed checklist protocol for the commissioning of LUNOS ventilation systems, ensuring proper installation, component verification, and functional testing for a successful system handover.
Preview Buku Lotsogolera Zokonzera za LUNOS Universal Controller 5/UNI-FT
Buku lotsogolera la LUNOS Universal Controller (Mtundu: 5/UNI-FT, Nambala: 40269), lomwe limafotokoza zinthu, tsatanetsatane waukadaulo, kulumikizana kwa magetsi, makonda ojambulira, ndi malangizo ogwiritsira ntchito kuti muwongolere bwino makina opumira.