Thank you for choosing the Innovair Air Conditioner Inverter Ductless Wall Mount Mini Split System. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new air conditioning unit. Please read this manual thoroughly before installation and use, and keep it for future reference.

This system is designed to provide both cooling and heating, offering a versatile solution for various indoor environments. Its inverter technology ensures high efficiency and consistent performance.

Innovair mini split system installed in various settings including a server room, indoor garden, garage, and small stores.

Figure 1.1: Versatile applications of the Innovair Mini Split System, suitable for server rooms, indoor gardens, garages, and commercial spaces.

Video 1.1: Kuthaview of Innovair systems, demonstrating their application in various HVAC solutions, including maintaining optimal temperatures in diverse environments.

2. Zambiri Zachitetezo

For your safety and to prevent damage to the unit, please observe the following precautions:

  • Chitetezo cha Magetsi: Ensure the unit is connected to a properly grounded 230V power supply. Do not use extension cords.
  • Kuyika: Kukhazikitsa kuyenera kuchitidwa ndi anthu oyenerera malinga ndi malamulo onse amagetsi am'deralo ndi adziko lonse.
  • Kusamalira: Chotsani magetsi musanakonze kapena kuyeretsa.
  • Firiji: This unit uses R410A refrigerant. Do not attempt to service the refrigerant system yourself.
  • Chilolezo: Maintain adequate clearance around both indoor and outdoor units for proper airflow.
  • Ana: Keep children away from the unit and remote control.
  • Zida Zoyaka: Musayike zinthu zoyaka moto pafupi ndi chipangizocho.

3. Zamalonda Zathaview

The Innovair Mini Split System consists of an indoor unit, an outdoor unit, and a remote control, along with an installation kit.

Innovair mini split system components including indoor unit, outdoor unit, remote control, and installation kit.

Figure 3.1: Main components of the Innovair Mini Split System, showing the indoor unit, outdoor unit, remote control, and included installation accessories.

Zofunika Kwambiri:

  • High Efficiency Inverter Technology: AHRI certified, providing energy savings.
  • Njira zingapo zogwirira ntchito: Includes Turbo Cool, Sleep Mode, Dehumidifier, and Hyper Heat.
  • Kuchita Pawiri: Operates in both AC cooling and Heat Pump heating modes.
  • Mwakonzeka kukhazikitsa: Comes with a 16FT installation kit and is pre-charged up to 25FT.
  • Chitetezo Chambiri: Features Gold-Fin Outdoor coating for durability and a Multi-Layer Filter for improved air quality.
  • WiFi Yayatsidwa: Allows for smart control via a mobile application.
Innovair mini split system providing both heating and cooling, depicted with a warm indoor scene and a cold outdoor scene, and vice versa.

Figure 3.2: The system's capability to provide both heating and cooling, adapting to different seasonal needs for year-round comfort.

Innovair mini split system with an electric bill being shredded, illustrating high efficiency and reduced electricity consumption.

Figure 3.3: Demonstration of the system's high efficiency, leading to lower electricity bills due to advanced inverter technology.

Innovair outdoor unit covered in ice and snow, with an orange glow at the bottom, indicating anti-freeze protection and low temperature operation.

Figure 3.4: The outdoor unit's anti-freeze protection and ability to operate effectively in low temperatures, ensuring reliable performance in cold climates.

Diagram showing four types of air filters: Catechin, HEPA, Vitamin C, and Aroma filters, highlighting their respective benefits.

Figure 3.5: The 4-in-1 Air Filter system, including Catechin, HEPA, Vitamin C, and Aroma filters, designed to improve indoor air quality by removing particles and odors.

4. Kukhazikitsa ndi Kuyika

The Innovair Mini Split System is designed for straightforward installation, with a 16FT installation kit included. However, professional installation is highly recommended to ensure proper functioning and adherence to safety standards.

Muuni Yoyikiratu:

  • Verify power supply (230V).
  • Ensure adequate space for both indoor and outdoor units, allowing for proper airflow and maintenance access.
  • Confirm the outdoor unit is placed on a stable, level surface.
  • Check that the refrigerant lines and electrical wiring can be routed safely and efficiently between units.

Installation Steps (Summary - Refer to detailed installation guide for full instructions):

  1. Kuyika Chipinda Chamkati: Secure the mounting plate to the wall, ensuring it is level.
  2. Drilling Wall Hole: Drill a hole through the wall for the refrigerant pipes, drain hose, and electrical cable.
  3. Connecting Piping and Wiring: Connect the refrigerant pipes, drain hose, and electrical wiring to the indoor unit.
  4. Kuyika Outdoor Unit: Place the outdoor unit on a stable base. Connect the refrigerant pipes and electrical wiring from the indoor unit.
  5. Kuwunika Kutulutsa Madzi ndi Kutulutsa Madzi: Evacuate the refrigerant lines using a vacuum pump. Perform a leak check on all connections.
  6. Kulumikiza Magetsi: Lumikizani chigawocho ku magetsi akuluakulu.
  7. Test Run: Perform a test run to ensure all functions are operating correctly.
Innovair mini split system installed in a room, showing the indoor unit mounted on the wall and the outdoor unit placed outside a window.

Chithunzi 4.1: Example of a typical installation, illustrating the placement of both indoor and outdoor units for optimal performance.

5. Malangizo Ogwiritsira Ntchito

Your Innovair Mini Split System can be controlled using the included remote control or via a WiFi-enabled mobile application.

Ntchito Zakutali:

Detailed diagram of the Innovair remote control with numbered buttons and their corresponding functions.

Figure 5.1: The advanced remote control, providing easy access to all system functions and settings.

  1. BATANI YOYAMBA/YOZImitsa: Dinani kuti muyatse kapena kuyimitsa chipangizocho.
  2. MITU YA BATANI: Imayenda motsatira njira zogwirira ntchito: Yokha, Yozizira, Youma, Yotentha, Yotenthetsa.
  3. BATANI YOTSATIRA: Amasintha liwiro la fan: Yokha, Yotsika, Yapakatikati, Yapamwamba.
  4. ROOM TEMPERATURE SWING BUTTONS (Up/Down Arrows): Imasintha kutentha kwachipinda komwe mukufuna.
  5. BATANI YOTSATIRA: Controls the horizontal louvers for airflow direction.
  6. SMART BUTTON: Activates fuzzy logic operation for optimized comfort.
  7. BATANI LOGONA: Engages sleep mode for quiet operation and energy saving during sleep.
  8. TIMER ON/OFF BUTTON: Sets or cancels the timer for automatic operation.
  9. SUPER BUTTON: Activates fast cooling or heating.
  10. CLOCK BUTTON: Amakhazikitsa nthawi yapano.
  11. DIMMER BUTTON: Turns the display light on or off.
  12. BATANI LOPHUNZITSA: Silences the unit's beeps.
  13. IFeel BUTTON: Activates the IFeel function, which senses temperature at the remote's location for more precise control.
  14. 8° HEAT BUTTON: Sets the heating temperature to 8°C (46°F) for anti-freeze protection in unoccupied spaces.

Ntchito Yoyambira:

  • Kuyatsa/Kuzimitsa: Dinani pa ON/WOZIMA batani.
  • Kusankha Mode: Dinani pa MODE button repeatedly until the desired mode (Cool, Heat, Dry, Fan, Auto) is displayed.
  • Kusintha Kutentha: Gwiritsani ntchito Mwamba / Kutsika mabatani kuti musunge kutentha kwanu.
  • Kusintha Liwiro la Mafani: Dinani pa FAN button to cycle through fan speeds.

WiFi Control:

For WiFi control, download the Innovair smart app from your device's app store. Follow the in-app instructions to connect your unit to your home network. This allows for remote control and scheduling features.

6. Kusamalira

Regular maintenance ensures optimal performance and longevity of your Innovair Mini Split System.

Kuyeretsa Zosefera:

The multi-layer air filters should be cleaned every two weeks or more frequently depending on usage and air quality. Dirty filters can reduce efficiency and airflow.

  1. Zimitsani unit ndikudula mphamvu.
  2. Tsegulani gulu lakutsogolo la chipinda chamkati.
  3. Carefully remove the air filters.
  4. Clean the filters with a vacuum cleaner or wash them with lukewarm water (below 40°C / 104°F).
  5. Allow filters to dry completely in a shaded area before re-installing. Do not expose to direct sunlight.
  6. Re-install the filters and close the front panel.

Kukonza Zipangizo Zakunja:

  • Kuyeretsa Koyilo: Periodically check the outdoor unit's coil for dirt and debris. Clean with a soft brush or water hose if necessary.
  • Chilolezo: Ensure no obstructions are blocking the airflow around the outdoor unit.
  • Ngalande: Yang'anani mzere wothira madzi oundana kuti muwone ngati pali zotsekeka.

Kuwona Kwanthawi:

  • Before the cooling season, ensure the outdoor unit is free of debris and the filters are clean.
  • Before the heating season, check for any ice buildup on the outdoor unit and ensure the drain pan is clear.

7. Mavuto

Musanalumikizane ndi chithandizo chamakasitomala, chonde onaninso zotsatirazi:

VutoChifukwa ChothekaYankho
Chigawo sichiyatsa.Palibe magetsi, chotsegula mawaya chagwa, mabatire owongolera kutali afa.Yang'anani magetsi, yambitsaninso chopachikira magetsi, sinthani mabatire akutali.
Kuziziritsa/kutentha kosakwanira.Dirty air filters, blocked outdoor unit, wrong mode selected, temperature setting too high/low.Clean filters, clear obstructions, select correct mode, adjust temperature.
Madzi akutuluka m'nyumba.Paipi yotulutsira madzi yotsekedwa, kuyika kosayenera.Clear drain hose, contact professional for inspection.
Phokoso lachilendo.Ziwalo zotayirira, zinthu zakunja, kusalingana kwa mafani.Inspect for loose parts, remove foreign objects. If persistent, contact support.
Kuwongolera kutali sikukugwira ntchito.Dead batteries, obstruction between remote and unit, remote malfunction.Replace batteries, remove obstruction, try resetting the remote.

If the problem persists after attempting these solutions, please contact Innovair customer support.

8. Zofotokozera

MalingaliroTsatanetsatane
MtunduInnovair
Nambala ya ModelWIN12H1V51
Mphamvu18000 BTUH (Cooling/Heating) / 3 Tons
Voltage230 volts
Kuchita bwino (SEER)18.00
Refrigerantndi R410A
Mtundu WoyikaSplit System
ZapaderaDehumidifier, WiFi Enabled
Miyeso YazinthuIndoor Unit: 32 x 11 x 8.5 inches (approx.)
Kulemera kwa chinthu24 pounds (approx. indoor unit)

9. Chitsimikizo ndi Thandizo

Innovair provides a limited warranty for this product. Please refer to the warranty card included with your purchase for specific terms and conditions, including coverage period and what is covered.

Thandizo la Makasitomala:

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Innovair customer support:

  • Webtsamba: Visit the official Innovair webtsamba lothandizira zothandizira komanso zidziwitso zolumikizana nazo.
  • Foni: Refer to your product packaging or warranty card for customer service phone numbers.
  • Malo Ogulitsira Paintaneti: For product information and to visit the Innovair store, you can go to Innovair Amazon Store.

When contacting support, please have your model number (WIN12H1V51) and purchase date ready.

Zolemba Zofananira - WIN12H1V51

Preview Innovair PXV36H2A Inverter Heat Pump Package Unit Installer's Guide
Comprehensive installer's guide for the Innovair PXV36H2A Inverter Heat Pump Package Unit, covering safety precautions, installation procedures, component details, electrical wiring, and testing.
Preview Innovair SLIM24 High Efficiency Heat Pump System: Installation and Owner's Manual
Comprehensive guide for installing and operating the Innovair SLIM24 High Efficiency Heat Pump System, covering safety precautions, maintenance, and troubleshooting for optimal performance.
Preview Innovair Single Zone Ductless Heat Pump Installation Manual
This manual provides detailed installation instructions for the Innovair Single Zone Ductless Heat Pump (Outdoor Unit), covering safety precautions, site preparation, installation steps, and wiring.
Preview Innovair SLIM4 SWV Series Indoor Unit User Manual
Comprehensive user manual for the Innovair SLIM4 SWV Series indoor air conditioning unit, covering safety precautions, operation, maintenance, and troubleshooting. Features include split system cooling and heat pump functionality with R454B refrigerant.
Preview Innovair Elite Heat Pump Ductless Splits Remote Controller Manual
This manual provides instructions for operating the Innovair Elite Heat Pump Ductless Splits remote controller. It covers features such as ON/OFF, fan speed control, mode selection, temperature adjustment, and special functions like I FEEL and SLEEP modes.
Preview Innovair M4 Split-Type Room Air Conditioner Installation Manual
This installation manual provides detailed instructions for the proper installation of the Innovair M4 Split-Type Room Air Conditioner. It covers safety precautions, product overview, installation steps, refrigerant piping, wiring, evacuation, test runs, and packing/unpacking.