This manual provides essential information for the safe and efficient operation, installation, and maintenance of the Red Lion Controls PAXI0020 Pax Counter/Rate Meter. Please read this manual thoroughly before installing or operating the device. Retain this manual for future reference.

2. Zambiri Zachitetezo

CHENJEZO: Improper installation or operation can result in personal injury or damage to the equipment. Always follow local and national electrical codes.

  • Disconnect all power before installing or servicing the unit.
  • Onetsetsani malo oyenera kuti musagwedezeke ndi magetsi.
  • Do not operate the device in environments exceeding its specified temperature and humidity ratings.
  • Ogwira ntchito oyenerera okha ndi omwe ayenera kuyika ndi kukonza.
  • Tsimikizirani kuti ma waya onse ndi otetezeka komanso olondola musanagwiritse ntchito magetsi.

3. Zamalonda Zathaview

The Red Lion Controls PAXI0020 is an AC-powered industrial counter and rate meter designed for precise measurement and display in various applications. It features a bright, easy-to-read display and intuitive front-panel controls for configuration and operation.

Front panel of the Red Lion Controls PAXI0020 Pax Counter/Rate Meter, showing a red digital display with the number 125005 and five control buttons labeled DSP, PAR, F1, F2, and RST.

This image displays the front face of the PAXI0020 unit. It features a large, red seven-segment LED display at the top, currently showing '125005'. Below the display are five push-buttons: 'DSP' (Display), 'PAR' (Parameter), 'F1' (Function 1), 'F2' (Function 2), and 'RST' (Reset). These buttons are used for navigating menus, adjusting settings, and controlling the meter's functions.

Front Panel Components:

  • Onetsani: High-visibility red LED display for showing count, rate, and parameter values.
  • Batani la DSP: Used to cycle through various display modes or views.
  • PAR Button: Accesses the parameter menu for configuration and setup.
  • F1 Button: Function key 1, typically user-programmable or for specific menu navigation.
  • F2 Button: Function key 2, typically user-programmable or for specific menu navigation.
  • Batani la RST: Resets the counter or clears error states.

4. Kukhazikitsa

4.1. Kuyika

The PAXI0020 is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals. Cut a panel opening according to the dimensions provided in the product's technical specifications sheet (not included in this manual). Secure the unit using the provided mounting hardware.

4.2. Kulumikizana

CHENJEZO: Ensure power is disconnected before making any wiring connections.

  • Magetsi: Connect the AC power supply to the designated terminals. Refer to the product label for specific voltagndi zofunika.
  • Zizindikiro Zolowetsa: Connect your counting or rate input signals (e.g., from sensors, encoders) to the appropriate input terminals. Pay close attention to polarity and signal type (e.g., NPN, PNP).
  • Kulumikiza Kwazolowera: If using control outputs, connect them to your external devices (e.g., relays, PLCs) as required by your application.
  • Kuyika pansi: Ensure the unit is properly grounded to a protective earth.

After all connections are made, double-check them for correctness and security before applying power.

5. Malangizo Ogwiritsira Ntchito

5.1. Yatsani

Once properly wired, apply AC power to the unit. The display will illuminate, typically showing the current count or rate value.

5.2. Basic Display Modes (DSP Button)

Dinani pa DSP button to cycle through available display modes. These may include:

  • Current Count Value
  • Current Rate Value
  • Peak/Min Values
  • Totalized Count

5.3. Parameter Configuration (PAR Button)

Press ndi kugwira PAR button to enter the parameter setup menu. Use the F1 ndi F2 buttons to navigate through parameters and adjust values. The DSP button may be used to confirm selections or move to the next digit/setting. Common parameters include:

  • Input type and scaling
  • Output functions and setpoints
  • Malo apakati
  • Sonyezani mlingo pomwe
  • Zokonda zachitetezo

Refer to the detailed programming guide (typically a separate document) for comprehensive parameter descriptions and configuration steps.

5.4. Resetting the Counter (RST Button)

Dinani pa Mtengo wa RST button to reset the active counter to zero. The function of the RST button may be configurable in the parameter menu (e.g., local reset, remote reset, or disabled).

6. Kusamalira

The PAXI0020 is designed for minimal maintenance. Regular inspection and cleaning are recommended.

  • Kuyeretsa: Gwiritsani ntchito zofewa, damp cloth to clean the front panel. Do not use abrasive cleaners or solvents.
  • Kuyendera: Periodically check wiring connections for tightness and signs of wear or corrosion. Ensure the unit's ventilation is not obstructed.
  • Kuwongolera: The unit is factory calibrated. If recalibration is suspected, contact Red Lion Controls support.

7. Mavuto

If the PAXI0020 is not functioning as expected, review the following common issues:

  • Palibe Chiwonetsero / Palibe Mphamvu:
    • Verify AC power supply is connected and active.
    • Check fuses (if applicable) in the power circuit.
    • Ensure wiring connections are secure.
  • Incorrect Count/Rate:
    • Check input signal wiring and sensor operation.
    • Verify input scaling and parameter settings in the PAR menu.
    • Ensure the correct input type (e.g., NPN, PNP) is selected.
  • Zolakwika Zowonetsera:
    • Consult the product's full technical manual for a list of error codes and their meanings.
    • Try cycling power to the unit.
  • Mabatani Sakuyankha:
    • Ensure the unit is not in a locked mode (check security settings in PAR menu).
    • Mphamvu zozungulira kupita kugawo.

If problems persist, contact Red Lion Controls technical support.

8. Zofotokozera

KufotokozeraMtengo
ChitsanzoPAXI0020
WopangaRed Lion Controls
Kulowetsa MphamvuAC (Specific voltage range typically on product label)
Kulemera kwa chinthu22 mapaundi
ASINB07CYPVM83
Tsiku Loyamba LikupezekaMeyi 8, 2018

9. Chitsimikizo ndi Thandizo

Warranty information for the Red Lion Controls PAXI0020 is typically provided with the product at the time of purchase or can be obtained directly from Red Lion Controls. For technical assistance, product documentation, or warranty claims, please contact Red Lion Controls customer support.

You can also visit the official Red Lion store for more information: Sitolo ya Red Lion pa Amazon

Zolemba Zofananira - PAXI0020

Preview Red Lion CUB®5 Miniature Electronic 8-Digit Dual Counter and Rate Indicator Manual
Comprehensive user manual for the Red Lion CUB®5, detailing its features as a miniature electronic 8-digit dual counter and rate indicator, including installation, programming, and communication options for industrial applications.
Preview Red Lion PAX Series 1/8 DIN Analog Input Panel Meters - User Manual
Comprehensive user manual for the Red Lion PAX Series 1/8 DIN Analog Input Panel Meters, covering specifications, installation, wiring, programming, troubleshooting, and option cards for models PAXD, PAXP, PAXS, PAXT, and PAXH.
Preview Red Lion CUB5 Miniature Dual Counter and Rate Indicator User Manual
Detailed user manual and datasheet for the Red Lion CUB5 miniature electronic 8-digit dual counter and rate indicator. Learn about features, specifications, installation, programming, and serial communications.
Preview Red Lion PAX Series 1/8 DIN Analog Input Panel Meters User Manual
User manual and technical datasheet for Red Lion PAX series 1/8 DIN analog input panel meters (PAXD, PAXP, PAXH, PAXS, PAXT). Covers specifications, installation, wiring, programming, and troubleshooting for industrial automation.
Preview Red Lion CUB5P Miniature Electronic 5-Digit Process Meter User Manual
Detailed user manual for the Red Lion CUB5P Miniature Electronic 5-Digit Process Meter, covering installation, wiring, programming, and specifications. Learn about its features, options, and operation.
Preview Red Lion CUB5 Miniature Electronic 8-Digit Dual Counter ndi Rate Indicator
Mafotokozedwe atsatanetsatane, chitsogozo chokhazikitsa, ndi buku la mapulogalamu a Red Lion CUB5 miniature electronic counter dual indicator ndi rate indicator. Zinthu zake zikuphatikizapo LCD kapena LED backlighting yomwe ingasankhidwe, ma relay ndi ma serial communication modules osankhidwa, ndi NEMA 4X/IP65 sealing.