Einhell GE-SP 3046 RB

Einhell GE-SP 3046 RB Multi-function Rainwater Collector and Drainage Pump User Manual

Model: GE-SP 3046 RB (Article No.: 4170438)

1. Mawu Oyamba

The Einhell GE-SP 3046 RB is a versatile multi-function pump designed for efficient rainwater collection and drainage. Its robust construction and intelligent features make it ideal for various applications around the home and garden, such as emptying rain barrels, tanks, or small ponds, and transferring water for irrigation. This manual will guide you through the proper use and care of your pump.

Einhell GE-SP 3046 RB pump with extension tube and float switch

Figure 1.1: Einhell GE-SP 3046 RB Multi-function Pump with Accessories.

2. Malangizo a Chitetezo

Always read and follow all safety instructions before operating the pump.

  • Onetsetsani kuti magetsi akufanana ndi voltage yofotokozedwa pa chizindikiro cha pompu.
  • Never operate the pump with a damaged power cable or plug. Have any damage repaired by a qualified electrician.
  • Musanyamule kapena kunyamula pompo pogwiritsa ntchito chingwe chake chamagetsi.
  • Sungani ana ndi anthu osaloledwa kutali ndi malo opangira opaleshoni.
  • Do not pump flammable, corrosive, or explosive liquids.
  • Ensure the pump is fully submerged in water during operation to prevent dry running and overheating.
  • Disconnect the pump from the power supply before performing any maintenance, cleaning, or when not in use.
  • Tetezani mpope ku chisanu.

3. Zida Zopangira

The Einhell GE-SP 3046 RB pump comes with several key components for its multi-functional use:

  • Chigawo cha Pampu: The main submersible pump with integrated motor and power cable.
  • Zimatayidwa Sinthani: Automatically activates/deactivates the pump based on water level.
  • Flexible Gooseneck: Allows for precise water discharge direction.
  • Adjustable Aluminum Tube: Provides variable height for water extraction, especially from deep containers.
  • Rain Stand: A stable base for positioning the pump and extension tube in rain barrels.
  • Integrated Cable Rewind: Convenient storage for the power cable on the pump housing.
  • Extension Tube Storage: Dedicated compartment on the pump housing for storing extension tubes.
Close-up of the Einhell GE-SP 3046 RB pump unit

Figure 3.1: Close-up of the Pump Unit.

Flexible gooseneck attachment for the pump

Figure 3.2: Flexible Gooseneck.

Storage compartment for extension tubes on the pump

Figure 3.3: Extension Tube Storage.

4. Kukhazikitsa

Follow these steps to set up your Einhell pump for operation:

  1. Assemble the Extension: If using the pump for rainwater collection from a barrel, attach the adjustable aluminum tube to the pump's outlet. Then, connect the flexible gooseneck to the top of the aluminum tube.
  2. Ikani Pampu: Place the pump unit into the water source (e.g., rain barrel, tank, or flooded area). Ensure the pump is stable and fully submerged. The minimum operating space required is approximately 40 x 40 cm, with a pump diameter of 24 cm.
  3. Adjust the Float Switch: The float switch controls the automatic on/off function of the pump. Adjust its position along the cable to set the desired minimum and maximum water levels for operation. A higher float position will require more water to activate the pump.
  4. Lumikizani ku Mphamvu: Plug the pump's power cable into a properly grounded electrical outlet. Ensure the outlet is protected by a residual current device (RCD) for safety.
Diagram showing minimum operating space for the pump

Figure 4.1: Minimum Operating Space.

Image demonstrating how to adjust the float switch

Figure 4.2: Adjusting the Float Switch.

5. Kugwira ntchito

Once set up, the Einhell GE-SP 3046 RB pump operates efficiently:

  • Ntchito Yodzichitira: The pump will automatically start when the water level rises to the activation point set by the float switch and stop when the water level drops below the deactivation point.
  • Ntchito pamanja: For continuous operation regardless of water level (e.g., for complete drainage), the float switch can often be fixed in an 'on' position. Refer to the specific instructions for your float switch model.
  • Water Transfer: Direct the flexible gooseneck or connected hose to where you want the water to be discharged. The pump can deliver up to 4,600 liters per hour with a maximum delivery height of 11 meters.
Woman using the Einhell pump to collect rainwater from a barrel

Figure 5.1: Pump in use for rainwater collection.

6. Kusamalira

Kusamalira nthawi zonse kumatsimikizira kuti pampu yanu ikugwira ntchito bwino komanso kwa nthawi yayitali:

  • Kuyeretsa: After each use, especially when pumping dirty water, rinse the pump with clean water. Remove any debris or foreign objects from the intake area at the bottom of the pump.
  • Onani Zotsekera: Periodically inspect the pump's intake and outlet for any blockages that could impede water flow.
  • Kuyang'ana Chingwe: Regularly check the power cable for any signs of wear, cuts, or damage.
  • Kosungirako Zima: Before the first frost, completely drain the pump of all water to prevent damage from freezing. Store the pump in a dry, frost-free location.

7. Mavuto

VutoChifukwa ChothekaYankho
Pompo sikuyambaPalibe magetsi
Float switch not activated
Galimoto yodzaza / kutenthedwa
Chongani kulumikizana kwa mphamvu ndi fuse
Adjust float switch position or manually activate
Disconnect power, let cool down, check for blockages
Mtengo wotsikaPartial blockage in intake/outlet
Hose kinked or too long/narrow
Madzi osakwanira
Malo olowera ndi otulutsira madzi oyera
Check hose for kinks, use appropriate diameter
Ensure pump is adequately submerged
Pampu imayenda mosalekezaFloat switch stuck in 'on' position
Water level not dropping below deactivation point
Check float switch for free movement
Ensure proper float switch adjustment for deactivation

8. Zofotokozera

MbaliKufotokozera
ChitsanzoMtengo wa GE-SP3046 RB
Nambala Yankhani4170438
Mphamvu350 W
Voltage230 V
Max. Mlingo Woyenda4,600 L/h (4.6 Litres per second)
Max. Kutumiza Kutalika11 m
Max. Impurity Size2.5 mm
Kutalika kwa Chingwe10 m
ZakuthupiImpact-resistant PVC Plastic
Kulemera3.8kg pa
Makulidwe (L x W x H)17 x 23 x 51 masentimita

9. Chitsimikizo ndi Thandizo

Einhell products are manufactured with high-quality materials and undergo strict quality controls. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Einhell website. For technical support, spare parts, or service inquiries, please contact Einhell customer service directly. Keep your purchase receipt as proof of purchase.

Zolemba Zofananira - Mtengo wa GE-SP3046 RB

Preview Einhell GE-SP 18 Li Akku-Klarwasserpumpe Bedienungsanleitung
Die offizielle Bedienungsanleitung für die Einhell GE-SP 18 Li Akku-Klarwasserpumpe. Enthält detaillierte Informationen zu Sicherheit, Installation, Betrieb, Wartung und Fehlerbehebung für dieses leistungsstarke Gartengerät.
Preview Einhell GE-CL 36 Li E Cordless Blower Vac Operating Instructions
Comprehensive operating instructions and safety guidelines for the Einhell GE-CL 36 Li E Cordless Blower Vac, detailing assembly, usage, maintenance, and troubleshooting.
Preview Einhell GE-LM 36/4in1 Li Akku-Multifunktionswerkzeug Bedienungsanleitung
Umfassende Bedienungsanleitung für das Einhell GE-LM 36/4in1 Li Akku-Multifunktionswerkzeug. Erfahren Sie mehr über Funktionen, Montage, Bedienung und Sicherheit dieses vielseitigen Gartengeräts.
Preview Einhell GE-CM 18/30 Li Cordless Lawn Mower: Operating Manual
Comprehensive operating instructions and safety guide for the Einhell GE-CM 18/30 Li cordless lawn mower. Learn about setup, operation, maintenance, and troubleshooting for your garden tool.
Preview Einhell GE-SP 18 Li Akku-Klarwasserpumpe: Bedienungsanleitung & Sicherheitshinweise
Umfassende Bedienungsanleitung für die Einhell GE-SP 18 Li Akku-Klarwasserpumpe. Erfahren Sie alles über sichere Handhabung, Installation, technische Daten, Wartung und Fehlerbehebung für Ihre Einhell Pumpe.
Preview Einhell GE-CF 18/2200 Li Cordless Fan Operating Manual
Dziwani za Einhell GE-CF 18/2200 Li fani yopanda zingwe. Bukuli limafotokoza mwatsatanetsatane za momwe mpweya wabwino wa m'nyumba umayendera, kuphatikiza mphamvu zopanda zingwe, liwiro losinthika, komanso kusuntha. Dziwani zambiri zachitetezo, kukonza, ndi chidziwitso cha chitsimikizo.