Mawu Oyamba
The Extech PRC30 is a handheld multifunction process calibrator designed for verifying the operation of various industrial instruments. It is suitable for use with sensors, thermocouple probes, controllers, panel meters, and other testing tools, particularly in temperature control and process troubleshooting applications.

Chithunzi 1: Patsogolo view of the Extech PRC30 Multifunction Process Calibrator, highlighting its display and control panel.
Zogulitsa Zamankhwala
- Multifunction capability for various process calibration tasks.
- Handheld design for portability and ease of use.
- Dot matrix LCD for clear display of readings and settings.
- Intuitive button layout for operation.
Khazikitsa
Kuyika kwa Battery
- Pezani chivundikiro cha chipinda cha batri kumbuyo kwa chipangizocho.
- Open the cover by sliding or unscrewing it as indicated.
- Insert the required batteries (type not specified, but typically AA or AAA) ensuring correct polarity.
- Sinthani chivundikiro cha chipinda cha batri mosamala.
Malangizo Ogwiritsira Ntchito
Kuwongolera ndi Kuwonetsaview
The Extech PRC30 features a clear dot matrix LCD and a user-friendly control panel. Refer to Figure 1 for button locations.
- Power Button (Orange, circular with power symbol): Press to turn the calibrator ON or OFF.
- Mabatani a Mivi (Mmwamba, Pansi, Kumanzere, Kumanja): Used for navigation, adjusting values, and selecting options.
- Ikani Button: Confirms selections or enters settings menus.
- UNIT Button (under TYPE): Changes the measurement unit (e.g., °F, °C).
- I/O Button (under MODE): Toggles between input and output modes.
- MEM Button (under STEP): Accesses memory functions, such as saving or recalling data.
- ZERO Button (under ZERO, with lightbulb symbol): Performs zero adjustment or backlight control.
- CJC (Cold Junction Compensation) Indicator: Indicates the status of cold junction compensation.
- APO (Auto Power Off) Indicator: Shows if the auto power off function is active.
- SOURCE Indicator: Indicates the device is in source mode.
- MEM.25 Indicator: Likely indicates a memory location or a specific memory function.
Basic Operation
- Yatsani: Press the orange power button. The display will illuminate.
- Posankha: Use the MODE (I/O) button to switch between input and output functions as required for your calibration task.
- Kusintha Makhalidwe: Use the Up/Down arrow buttons to adjust output values or navigate through menu options. The Left/Right arrow buttons may be used for digit selection or fine-tuning.
- Kusintha mayunitsi: Press the UNIT button to cycle through available measurement units (e.g., °F, °C).
- Kusintha kwa Zero: Use the ZERO button to perform a zero adjustment for current measurements or to activate the display backlight.
- Memory Ntchito: Press the MEM button to save current readings or recall previously stored data.
- Kuzimitsa Mphamvu: Press and hold the orange power button until the display turns off. The Auto Power Off (APO) function will also turn off the device after a period of inactivity.
Kusamalira
- Kuyeretsa: Pukuta chipangizocho ndi chofewa, damp nsalu. Osagwiritsa ntchito zotsukira abrasive kapena solvents.
- Posungira: Store the calibrator in a dry, cool environment when not in use. Remove batteries if storing for extended periods to prevent leakage.
- Kusintha Battery: Replace batteries promptly when the low battery indicator appears on the display to ensure accurate operation.
- Kuwongolera: Kuyesa nthawi zonse ndi anthu oyenerera kumalimbikitsidwa kuti muyeso ukhale wolondola.
Kusaka zolakwika
| Vuto | Chifukwa Chotheka | Yankho |
|---|---|---|
| Chipangizo sichimayatsidwa. | Mabatire akufa kapena oyika molakwika. | Yang'anani momwe batire ilili ndipo muyike mabatire atsopano. |
| Kuwerenga molakwika. | Needs calibration; environmental interference; incorrect settings. | Perform zero adjustment; ensure stable environment; verify measurement settings; consider professional calibration. |
| Chiwonetsero ndi chopanda kanthu kapena chochepa. | Low battery; backlight off. | Replace batteries; press the ZERO button to activate backlight. |
Zofotokozera
- Chitsanzo: Mtengo wa PRC30
- Kufotokozera: Multifunction Process Calibrator
- Mtundu Wowonetsera: Dothi la matrix LCD
- Makulidwe (Utali x M'lifupi x Utali): 6.375 mu (15.9 cm) x 3.25 mu (8 cm) x 1.75 mu (4.4 cm)
- Kutentha kwa Ntchito: 41 mpaka 104°F (5 mpaka 40°C)
- Chinyezi Chogwira Ntchito: <80% RH
- Gwero la Mphamvu: Mabatire
- Koyambira: Zapangidwa ku Taiwan
Chitsimikizo ndi Thandizo
The Extech PRC30 Multifunction Process Calibrator comes with a 1-Year Universal Guarantee.
For technical support, service, or warranty claims, please refer to the contact information provided with your purchase documentation or visit the official Extech Instruments webmalo.