1. Mawu Oyamba
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Finder 140182300000PAS Multifunction Timer/Staircase Relay. Please read this manual carefully before installation and use to ensure proper function and safety.
2. Zambiri Zachitetezo
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel in accordance with all local and national electrical codes.
- Nthawi zonse dulani magetsi musanayike kapena kukonza chipangizocho.
- Ensure the device is installed in a suitable enclosure to protect against environmental factors.
- Verify correct wiring connections to prevent damage to the device or connected equipment.
- Osapitirira vol yotchulidwatage ndi mavoti apano.
3. Zamalonda Zathaview
The Finder 140182300000PAS is a versatile multifunction timer and staircase relay designed for various electrical control applications. It features a 230V operating voltage, a 1 NO (normally open) contact, and a 16A current rating. Its compact design allows for easy integration into electrical panels.

Chithunzi 1: Patsogolo view of the Finder 140182300000PAS Multifunction Timer/Staircase Relay. This image shows the device's casing, terminals, and the adjustable timer dial.

Chithunzi 2: Example application of the Finder 140182300000PAS controlling staircase lighting. The relay is shown in an inset, demonstrating its use in a typical residential or commercial setting.

Chithunzi 3: Another application example, showing the Finder 140182300000PAS managing lighting for a modern spiral staircase. This highlights the device's suitability for various architectural lighting designs.
4. Kukhazikitsa ndi Kuyika
4.1 Miyeso Yathupi
Refer to the dimensional drawing for precise measurements to ensure proper fit and mounting.

Chithunzi 4: Dimensional drawing for the Type 14.01 relay, showing height, width, and depth in millimeters. This diagram is crucial for planning installation space.
4.2 Zithunzi za Wiring
The Finder 140182300000PAS supports both 3-wire and 4-wire connection types. Select the appropriate diagram for your installation.

Chithunzi 5: Wiring Diagram Type 14.01 for a 3-wire connection. This diagram illustrates how to connect the relay to the power supply and load using a 3-wire configuration, typically for staircase lighting with a common neutral.

Chithunzi 6: Wiring Diagram Type 14.01 for a 4-wire connection. This diagram shows the connections for a 4-wire setup, which might be used in systems requiring separate control wires for the relay and the load.
5. Malangizo Ogwiritsira Ntchito
5.1 Kusintha kwa Nthawi
The device features an adjustable timer dial on its front face. To set the desired timing duration:
- Locate the orange dial labeled 'T(min)' on the front of the relay.
- Rotate the dial to align the indicator with the desired time setting (e.g., 5, 10, 15, 20 minutes).
- The selected time will determine how long the connected load remains active after activation.
5.2 Multifunction Operation
The Finder 140182300000PAS operates as both a staircase timer and a multifunction relay. When activated (e.g., by a push-button switch), the relay will close its contact, powering the connected load for the duration set on the timer. It can be used for applications such as:
- Staircase lighting control.
- Timed ventilation systems.
- General purpose timed switching.
6. Kusamalira
The Finder 140182300000PAS is designed for long-term, maintenance-free operation. However, periodic checks are recommended:
- Ensure all wiring connections remain secure.
- Sungani chipangizocho kukhala chopanda fumbi ndi zinyalala.
- Inspect for any signs of physical damage or overheating.
- If the device is exposed to harsh environments, consider more frequent inspections.
WARNING: Always disconnect power before performing any maintenance or inspection.
7. Mavuto
If the device is not functioning as expected, consider the following:
- No power to the load: Check the main power supply, circuit breaker, and all wiring connections. Ensure the device is receiving 230V.
- Timer not activating: Verify the input signal (e.g., from the push-button switch) is correctly connected and functioning.
- Incorrect timing duration: Re-check the setting on the 'T(min)' dial.
- Kutentha kwa chipangizo: Ensure the load current does not exceed 16A. Check for proper ventilation around the device.
If issues persist after checking these points, consult a qualified electrician or contact Finder customer support.
8. Zofotokozera
| Mbali | Kufotokozera |
|---|---|
| Wopanga | Wopeza |
| Nambala ya Model | 140182300000 PAS |
| Makulidwe azinthu (L x W x H) | 8.4 x 1.8 x 5.9 masentimita |
| Kulemera | 60g pa |
| Mtundu | Imvi |
| Zakuthupi | Pulasitiki |
| Voltage | 230 volts |
| Contact Type | 1 AYI (Nthawi zambiri imatsegulidwa) |
| Mawerengedwe Apano | 16 A |
| Nambala ya Zokonda | 8 (Timer functions) |
| Battery(ies) Included | Ayi |
| Battery(ies) Required | Ayi |
| Kupezeka kwa Zida Zosinthira | Zambiri sizikupezeka |
8.1 Certification
The product complies with various international standards.

Chithunzi 7: Product certifications, including CE, UKCA, EAC, and Q-Mark, indicating compliance with European, UK, Eurasian, and quality standards respectively.
9. Chitsimikizo ndi Thandizo
For warranty information and technical support, please refer to the official Finder webwebusayiti kapena funsani wofalitsa wakomweko. Sungani risiti yanu yogulira ngati umboni wogula.