Red Lion CUB5R000

Red Lion CUB5R000 Multi-function Counter/Rate Indicator User Manual

Model: CUB5R000

1. Zamalonda Zathaview

The Red Lion CUB5R000 is a versatile multi-function counter designed for industrial applications. This device offers comprehensive user programming capabilities and can be configured as a single or dual counter with integrated rate indication. Its flexible design allows for various input types and display options.

The CUB5R000 processes incoming pulses, applying a user-defined count scale factor to accurately determine the displayed count. It supports two primary inputs: Input A for the main count signal, and Input B for advanced functions such as quadrature sensing, dual counter operations, anticoincidence counting, or up/down control.

Red Lion CUB5R000 Multi-function Counter with digital display showing '346 789.00' and 'SEL' and 'RST' buttons.

Chithunzi 1: Patsogolo view of the Red Lion CUB5R000 Multi-function Counter. The digital display shows a value of '346 789.00'. Below the display, there are two control buttons labeled 'SEL' (Select) on the left and 'RST' (Reset) on the right. The Red Lion logo is visible in the upper right corner of the device's faceplate.

2. Zofunika Kwambiri

  • Multi-function Capability: Operates as a single or dual counter with rate indication.
  • User Programmable: Offers complete user programming for various operational modes.
  • Chiwonetsero Chokhazikika: Display can be toggled manually or automatically between selected readings.
  • High Count Speed: Supports count speeds up to 20 kHz.
  • Programmable Scaling: Allows for programmable scaling factors for both count and rate measurements.
  • Advanced Input Options: Input B supports quadrature, dual counter, anticoincidence, or up/down control counting.
  • Display Color Change: Capability for display color change at preset output conditions.
  • Optional Relay Output: Supports optional relay output functionality.

3. Kukhazikitsa ndi Kuyika

Proper installation is crucial for the reliable operation of the CUB5R000. This section provides general guidelines. For detailed wiring diagrams and specific installation instructions, refer to the comprehensive technical manual provided with the product or available from the manufacturer's webmalo.

3.1 Kukwera

The CUB5R000 is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals. Secure the unit firmly using the provided mounting hardware.

3.2 Kulumikiza kwa Magetsi

All electrical connections should be performed by qualified personnel in accordance with local and national electrical codes. Ensure power is disconnected before making any connections.

  • Magetsi: Connect the appropriate power supply as specified in the technical manual.
  • Zizindikiro Zolowetsa: Connect pulse inputs (Input A and Input B) according to your application's requirements (e.g., count, rate, quadrature).
  • Kulumikiza Kwazolowera: If using optional relay outputs, connect them to the controlled devices as per the wiring diagram.

Warning: Incorrect wiring can damage the unit and pose safety hazards. Always consult the full technical manual.

4. Malangizo Ogwiritsira Ntchito

The CUB5R000 features user-friendly controls for configuration and operation. The primary interface consists of the digital display and two buttons: 'SEL' (Select) and 'RST' (Reset).

4.1 Basic Operation

  • Yatsani: Once correctly wired and powered, the unit will display the current count or rate value.
  • Display Toggle: Dinani pa SEL button to manually cycle through different display modes (e.g., Count 1, Count 2, Rate). The unit can also be configured for automatic display cycling.
  • Kukonzanso Makhalidwe: Dinani pa Mtengo wa RST button to reset the active counter value. This function may be configurable to require a longer press or external input for safety.

4.2 Programming Modes

Accessing programming modes allows for configuration of parameters such as count scale factors, input types, output behavior, and display settings. Refer to the detailed programming section in the technical manual for specific sequences and parameter definitions.

  • Typically, programming mode is entered by holding down the SEL button for a specified duration.
  • Gwiritsani ntchito SEL button to navigate through parameters and the Mtengo wa RST batani kuti musinthe ma values.
  • Save changes before exiting programming mode.

5. Kusamalira

The Red Lion CUB5R000 is designed for minimal maintenance. Regular inspection and cleaning are recommended to ensure optimal performance and longevity.

  • Kuyeretsa: Periodically clean the display and housing with a soft, damp cloth. Avoid abrasive cleaners or solvents that could damage the unit.
  • Kuyendera: Routinely check all wiring connections for tightness and signs of wear or damage. Ensure the unit is free from dust and debris, especially around ventilation areas.
  • Zachilengedwe: Onetsetsani kuti malo ogwirira ntchito amakhalabe mkati mwa kutentha komwe kwatchulidwako ndi chinyezi kuti mupewe kulephera msanga.

Caution: Do not attempt to open the unit for internal cleaning or repairs. Refer all servicing to qualified personnel.

6. Mavuto

This section provides basic troubleshooting steps for common issues. For more complex problems, consult the full technical manual or contact Red Lion technical support.

VutoChifukwa ChothekaYankho
Kuwonetsera kulibe kanthuNo power supply; Incorrect wiring; Unit failure.Chongani kulumikizana kwa magetsi ndi kuchuluka kwa magetsitage. Verify wiring against the manual. If problem persists, contact support.
Counter not incrementingNo input signal; Incorrect input wiring; Input signal too weak/fast; Incorrect scaling.Verify input signal presence and strength. Check input wiring. Adjust input sensitivity or scaling in programming mode.
Incorrect count/rate valueIncorrect scaling factor; Wrong input type selected; Sensor issue.Review and adjust scaling factors in programming. Confirm correct input type (e.g., quadrature). Check sensor operation.
Mabatani osayankhaUnit frozen; Hardware issue.Cycle power to the unit. If unresponsive, contact technical support.

7. Mafotokozedwe aukadaulo

KufotokozeraMtengo
Nambala ya ModelCUB5R000
MtunduRed Lion
WopangaCOLE-PARMER
Count SpeedKufikira 20 kHz
Mitundu YolowetsaCount (Input A), Quadrature, Dual Counter, Anticoincidence, Up/Down Control (Input B)
Gwero la MphamvuYoyendetsedwa ndi Battery
Kulemera kwa chinthuMa 0.01 ounces (pafupifupi magalamu 0.28)
Makulidwe a Phukusi4 x 3.2 x 2.75 mainchesi
Tsiku Loyamba LikupezekaFebruary 7, 2013

8. Chitsimikizo ndi Thandizo

For warranty information, technical support, or service inquiries regarding your Red Lion CUB5R000, please contact Red Lion Controls directly or refer to their official website. Ensure you have your product model number (CUB5R000) and date of purchase available when contacting support.

Manufacturer: COLE-PARMER

Kuti mudziwe zambiri, pitani ku Red Lion Store on Amazon.

Zolemba Zofananira - CUB5R000

Preview Red Lion CUB®5 Miniature Electronic 8-Digit Dual Counter and Rate Indicator Manual
Comprehensive user manual for the Red Lion CUB®5, detailing its features as a miniature electronic 8-digit dual counter and rate indicator, including installation, programming, and communication options for industrial applications.
Preview Red Lion CUB5 Miniature Dual Counter and Rate Indicator User Manual
Detailed user manual and datasheet for the Red Lion CUB5 miniature electronic 8-digit dual counter and rate indicator. Learn about features, specifications, installation, programming, and serial communications.
Preview Red Lion CUB5 Miniature Electronic 8-Digit Dual Counter and Rate Indicator
Detailed specifications, installation guide, and programming manual for the Red Lion CUB5 miniature electronic 8-digit dual counter and rate indicator. Features include selectable LCD or LED backlighting, optional relay and serial communication modules, and NEMA 4X/IP65 sealing.
Preview Red Lion DITAK 8 Adjustable Timebase 5-Digit Rate Indicator Manual
This document provides detailed specifications, installation guidelines, and troubleshooting information for the Red Lion DITAK 8 Adjustable Timebase 5-Digit Rate Indicator. It covers features, electrical specifications, EMC compliance, and programming.
Preview Red Lion CL01 Paradigm 2x20 LCD Operator Interface Terminal Manual
Technical manual and specifications for the Red Lion CL01 Paradigm 2x20 LCD Operator Interface Terminal, covering features, installation, safety, and troubleshooting.
Preview Red Lion RAM-6021 Wired Router: Hardware and Installation Guide
Chiwongolero chokwanira cha hardware ndi kukhazikitsa kwa Red Lion RAM-6021 Wired Router, yofotokozera, kuyika, kulumikiza, chitetezo, ndi chithandizo.