1. Mawu Oyamba
This instruction manual provides comprehensive guidance for the installation, configuration, and operation of the JASCO GE Z-Wave On/Off Relay Switch, Model 45609 (ZW4001). This device is designed to integrate into your Z-Wave wireless lighting control system, enabling remote ON/OFF control of permanently installed lighting fixtures and ceiling fans.
The GE Z-Wave On/Off Relay Switch offers a convenient solution for smart home automation, compatible with various lighting types including CFL, LED, Xenon, Halogen, Fluorescent, and Incandescent. It supports both 2-way and 3-way wiring configurations when used with an auxiliary switch.
2. Zofunika Zachitetezo
CHENJEZO: KUCHIPWIRA KWA NTCHITO YA ELECTRIC. Installation involves high voltage wiring. Improper installation can result in serious injury or death. Always consult a qualified electrician if you are unsure about any part of the installation process.
- LULUKANITSA MPHAMVU: Before installation, turn OFF the power to the switch location at the circuit breaker or fuse box.
- NEUTRAL WIRE REQUIRED: This switch requires a neutral wire for operation. If your existing switch box does not have a neutral wire, consult a qualified electrician.
- KUGWIRITSA NTCHITO MKATI POKHA: This device is intended for indoor use in dry locations.
- LOAD COMPATIBILITY: Ensure the connected load does not exceed the switch's maximum rating.
- KULAMULIRA KWA ANTHU: This switch provides ON/OFF control for ceiling fans; speed control is not supported.
3. Zamkatimu Phukusi
- GE Z-Wave On/Off Relay Switch (Model 45609 / ZW4001)
- Wiring Nuts (typically included, but may vary)
- Buku Lachidziwitso (chikalata ichi)
Zindikirani: A wallplate is not included and must be purchased separately.
4. Kukhazikitsa ndi Kuyika
Follow these steps carefully to install your GE Z-Wave On/Off Relay Switch. If you are unfamiliar with electrical wiring, please consult a qualified electrician.
4.1 Wiring Diagram Overview
The switch requires Line (Hot), Load, Neutral, and Ground connections. For 3-way installations, an auxiliary switch (e.g., GE 45610) and a traveler wire are also required.

Chithunzi 1: Patsogolo view of the GE Z-Wave On/Off Relay Switch (Model 45609) without a wallplate, showing the rocker switch and mounting bracket. The "TOP" indicator is visible at the top of the metal bracket. Electrical ratings (120VAC, 60Hz, 15A Resistive Load) are printed on the side.
4.2 Njira zoyika
- Zimitsani Mphamvu: Locate the circuit breaker or fuse that supplies power to the switch box. Turn it OFF completely. Verify power is off using a voltagndi tester.
- Chotsani Kusintha Kwaposachedwa: Carefully remove the wallplate and unscrew the existing switch from the wall box. Disconnect the wires from the old switch, noting which wire was connected to which terminal. It is recommended to label the wires (Line, Load, Neutral, Ground, Traveler if applicable).
- Dziwani Mawaya:
- Line (Hot): Connects to the electrical panel, providing power.
- Katundu: Connects to the light fixture or fan.
- Wosalowerera ndale: Typically white, required for the switch to operate.
- Pansi: Waya wonyezimira kapena wobiriwira.
- Traveler (for 3-way): Connects to the auxiliary switch.
- Wire the Z-Wave Switch: Connect the wires to the GE Z-Wave switch terminals as follows:
- Ground Waya: Connect to the green GROUND terminal.
- Waya Wapakati: Connect to the white NEUTRAL terminal.
- Line (Hot) Wire: Connect to the black LINE terminal.
- Katundu Waya: Connect to the black LOAD terminal.
- Traveler Wire (if 3-way): Connect to the red TRAVELER terminal. Cap off the traveler wire if not used.
- Mount the Switch: Carefully fold the wires and push the switch into the wall box. Secure the switch with the provided screws.
- Install Wallplate: Attach the new wallplate (not included) over the switch.
- Bwezerani Mphamvu: Yatsaninso magetsi pa choyatsira magetsi.
- Mayendedwe Oyesera: Manually press the rocker switch to ensure the connected light or fan turns ON and OFF.

Chithunzi 2: Patsogolo view of the GE Z-Wave On/Off Relay Switch (Model 45609) with a light almond wallplate installed. This illustrates the finished appearance of the switch in a standard electrical box.
5. Malangizo Ogwiritsira Ntchito
5.1 Kuwongolera pamanja
The GE Z-Wave On/Off Relay Switch can be operated manually:
- Press the top of the rocker switch to turn the connected device ON.
- Press the bottom of the rocker switch to turn the connected device OFF.
- An LED indicator on the switch illuminates to show its location in a dark room.
5.2 Kuphatikizidwa kwa Netiweki ya Z-Wave (Kuphatikizana)
To add the switch to your Z-Wave network:
- Place your Z-Wave controller into inclusion (pairing) mode. Refer to your controller's instruction manual for specific steps.
- Once the controller is in inclusion mode, quickly tap the top or bottom of the rocker switch once. The LED indicator on the switch may flash to confirm inclusion.
- The controller will confirm successful inclusion. You can now control the switch remotely through your Z-Wave network.
Zindikirani: Pairing typically requires a light, quick tap, not a prolonged press.
5.3 Z-Wave Network Exclusion (Unpairing)
To remove the switch from your Z-Wave network:
- Place your Z-Wave controller into exclusion (unpairing) mode. Refer to your controller's instruction manual for specific steps.
- Once the controller is in exclusion mode, quickly tap the top or bottom of the rocker switch once. The LED indicator on the switch may flash to confirm exclusion.
- The controller will confirm successful exclusion. The switch is now removed from your Z-Wave network.
6. Kusamalira
- Kuyeretsa: To clean the switch, wipe it with a soft, damp nsalu. Osagwiritsa ntchito zotsukira abrasive kapena solvents.
- Palibe Magawo Ogwiritsa Ntchito: There are no user-serviceable parts inside the switch. Do not attempt to open or repair the device.
- Zosintha za Firmware: Any firmware updates would be managed through your Z-Wave controller, if supported.
7. Mavuto
| Vuto | Chifukwa Chotheka | Yankho |
|---|---|---|
| Light/Fan does not turn ON/OFF manually. |
|
|
| Switch does not respond to Z-Wave controller. |
|
|
| LED indicator is not working. |
|
|
8. Zofotokozera
| Mbali | Tsatanetsatane |
|---|---|
| Nambala ya Model | 45609 (ZW4001) |
| Mtundu | JASCO (GE) |
| Mphamvu | 120VAC, 60Hz |
| Maximum Katundu | 15A Resistive Load |
| Wopanda zingwe Technology | Z-Wave |
| Kukonzekera kwa Wiring | 2-way or 3-way (with auxiliary switch) |
| Waya Wapakati | Chofunikira |
| Makulidwe (L x W x H) | 10.49 x 5.41 x 4.45 masentimita (pafupifupi 4.13 x 2.13 x 1.75 mainchesi) |
| Kulemera | 113.4 g (pafupifupi 4 oz) |
| Operation Mode | CHOKHA |
| Sinthani Mtundu | Rocker |
| Mtundu Wokwera | Wall Mount (standard electrical box) |
| Mtundu Wowongolera | SmartThings (compatible with other Z-Wave controllers) |
9. Chitsimikizo ndi Thandizo
For warranty information and technical support, please refer to the documentation provided with your purchase or visit the JASCO Products webmalo. Sungani umboni wanu wogula kuti mutenge chitsimikizo.
JASCO Products provides customer support for their Z-Wave devices. Contact information can typically be found on their official webtsamba kapena pakupanga kwazinthu.