Red Lion RL-WC50TA

Red Lion RL-WC50TA Cast Iron Sewage Pump User Manual

Model: RL-WC50TA (Part Number: 14942748)

1. Mawu Oyamba

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Red Lion RL-WC50TA Cast Iron Sewage Pump. Please read all instructions carefully before use to ensure proper function and longevity of the product.

The Red Lion RL-WC50TA is a robust 1/2 HP submersible pump designed for high-volume transfer of sewage or effluent. It is capable of handling semi-solids up to 2 inches in diameter, making it suitable for applications such as basement washrooms, sewage systems, or holding tanks. This pump is equipped with a piggyback tethered float switch for automatic operation.

Important: This pump is not recommended for pond use.

2. Zambiri Zachitetezo

Always prioritize safety during installation, operation, and maintenance. Failure to follow safety guidelines can result in serious injury or property damage.

  • Chitetezo cha Magetsi: Ensure the power supply matches the pump's requirements (115 Volts). Always disconnect power before servicing the pump. Use a ground fault circuit interrupter (GFCI) for electrical connections.
  • Zida Zodzitetezera Payekha (PPE): Wear appropriate PPE, including gloves and eye protection, when handling the pump or working with wastewater.
  • Kuyika Moyenera: Install the pump according to local plumbing and electrical codes. Ensure the pump is placed on a solid, level surface in the basin.
  • Zida Zowopsa: Be aware that sewage and effluent contain hazardous biological materials. Avoid direct contact and ensure proper disposal.
  • Ana ndi Ziweto: Keep children and pets away from the pump and installation area.

3. Zamalonda Zathaview

The Red Lion RL-WC50TA is engineered for durability and reliable performance in demanding wastewater applications.

Red Lion RL-WC50TA Cast Iron Sewage Pump

Figure 1: Red Lion RL-WC50TA Cast Iron Sewage Pump with tethered float switch.

Zofunika Kwambiri:

  • Ntchito Yolemera Kwambiri: Cast iron housing and vortex-style impeller for durability and efficient solids handling.
  • Kuthana ndi zolimba: Capable of passing semi-solids up to 2 inches in diameter, preventing clogs.
  • Ntchito Yodzichitira: Piggyback tethered float switch for automatic activation and deactivation based on water levels.
  • Kuteteza Magalimoto: 1/2 HP PSC dual bearing motor with thermal overload protection for extended life.
  • CSA Listed: Certified for safety in both USA and Canada.

Zamkati:

Diagram of Red Lion RL-WC50TA internal components

Figure 2: Diagram illustrating the internal components of the RL-WC50TA, including the 1/2 HP high-efficiency PSC motor with thermal overload protection, dual ball bearings, cast iron housing, stainless steel rotor shaft, cast iron vortex style impeller, and 2-inch FNPT threaded discharge.

4. Kukhazikitsa ndi Kuyika

Proper installation is critical for the performance and safety of your sewage pump. If you are unsure about any step, consult a qualified professional.

Muuni Yoyikiratu:

  • Verify power supply (115 Volts).
  • Onetsetsani kuti basin diameter is at least 18 inches.
  • Gather necessary tools and plumbing fittings (2-inch FNPT discharge).
  • Confirm the installation area is clear and accessible.

Masitepe oyika:

  1. Konzani Basin: Ensure the sump basin is clean and free of debris. The pump should rest on a solid, level surface at the bottom of the basin.
  2. Mapaipi Otulutsa Magazi Olumikizirana: Attach a 2-inch FNPT discharge pipe to the pump outlet. Use appropriate sealant or tape to ensure a watertight connection.
  3. Ikani Check Valve: Install a check valve in the discharge line above the pump to prevent backflow of water into the basin.
  4. Ikani Pampu: Chepetsani pampu mosamala mu basin. Ensure the float switch can move freely without obstruction from the pump, basin walls, or piping.
  5. Kulumikiza Magetsi: Connect the pump's 10-ft. power cord to a dedicated 115 Volt, GFCI-protected outlet. The piggyback plug allows for automatic or manual operation.

Understanding Pump Types (Video):

For a better understanding of different pump types and their applications, including sewage and effluent pumps, please watch the following informational video:

Video 1: This video explains the differences between sump, sewage, effluent, and utility pumps, helping users understand the correct application for each type. Provided by Franklin Electric - Little Giant.

5. Malangizo Ogwiritsira Ntchito

The Red Lion RL-WC50TA operates automatically via its tethered float switch. It can also be manually tested.

Ntchito Yodzichitira:

  • The pump will activate when the water level reaches approximately 17.5 inches.
  • The pump will continue to run until the water level falls to approximately 7.5 inches, at which point it will shut off.
  • Ensure the float switch has a clear path of travel and is not restricted by any objects in the basin.
Red Lion RL-WC50TA automatic operation with piggyback float switch

Figure 3: Illustration of the piggyback float switch and its activation/deactivation levels for automatic operation. The piggyback plug allows for switching to manual mode for testing or maintenance.

Manual Operation/Testing:

The piggyback plug design allows for manual testing of the pump. To operate manually, simply unplug the float switch plug from the wall outlet, then plug the pump's main power cord directly into the wall outlet. The pump will run continuously. To return to automatic operation, unplug the pump's main power cord and re-insert the float switch plug into the wall outlet.

Caution: Do not run the pump dry for extended periods in manual mode, as this can cause damage.

6. Kusamalira

Kusamalira nthawi zonse kumatsimikizira kuti pampu yanu ikugwira ntchito bwino komanso imawonjezera moyo wake.

  • Kuyendera pamwezi: Check the sump basin for excessive debris. Remove any large objects that could obstruct the float switch or pump intake.
  • Onani Kusintha kwa Float: Periodically test the float switch by manually raising it to ensure the pump activates and deactivates correctly.
  • Koyeretsa Impeller: If the pump's performance decreases, disconnect power and inspect the impeller for clogs or buildup. Clean as necessary.
  • Kuwunika kwa Power Cord: Examine the power cord for any signs of damage, fraying, or wear. Replace if damaged.
  • Winterization (ngati ikuyenera): If the pump is in an area subject to freezing temperatures and will not be used, remove it from the basin, clean it thoroughly, and store it in a dry, frost-free location.

7. Mavuto

Onani pa tebulo ili m'munsimu kuti mudziwe zomwe zimagwirizana komanso zomwe zingatheke.

VutoChifukwa ChothekaYankho
Pump siyithamangaNo power; tripped breaker; faulty float switch; clogged impellerCheck power supply and breaker; test float switch; clear impeller
Pampu imayenda mosalekezaFloat switch stuck in ON position; faulty float switchCheck float switch for obstructions; replace float switch if faulty
Pampu ikuyenda koma palibe madzi omwe akutulukaClogged intake or discharge pipe; air lock; low water levelClear clogs; prime pump if air locked; ensure sufficient water level
Pampu imayenda pafupipafupi kwambiriBasin too small; check valve not holding; float switch differential too narrowConsult a professional for basin size; inspect/replace check valve; adjust float switch if possible (refer to specifications)

8. Zofotokozera

Detailed technical specifications for the Red Lion RL-WC50TA Sewage Pump.

Red Lion RL-WC50TA Dimensions Diagram

Figure 4: Dimensions diagram for the Red Lion RL-WC50TA Sewage Pump. Height (A): 15.8" (401 mm), Length (B): 9" (229 mm), Width (C): 6" (152 mm), Weight: 30 lbs (13.6 kg).

KufotokozeraMtengo
ChitsanzoRL-WC50TA
Gawo Nambala14942748
MtunduMkango Wofiira
Horsepower (HP)0.5 (1/2 HP)
Voltage115 volts
Ampmkwiyo9 Amps
Wattage950 watts
Maximum Flow Rate5600 GPH (Magaloni 93 Pa Mphindi)
Maximum Lifting Height (Shutoff)22 mapazi
Kukula KwachanguFNPT ya mainchesi 2
Kusamalira SolidsUp to 2-inch diameter semi-solids
Mtundu wa Switch FloatPiggyback Tethered
Float Switch ON Level17.5 mu
Float Switch OFF Level7.5 mu
Kutalika kwa Chingwe Champhamvu10 mapazi
Minimum Basin Diameter18 mu
ZakuthupiKuponya Chitsulo
Makulidwe azinthu (L x W x H)9" x 6" x 15.8"
Kulemera kwa chinthu29.8 mapaundi
Red Lion RL-WC50TA Performance Curve and Table

Figure 5: Performance curve and table for the Red Lion RL-WC50TA, showing Gallons Per Hour (GPH) at various lift heights and the shut-off point.

9. Chitsimikizo

The Red Lion RL-WC50TA Sewage Pump comes with a 2-year wopanga chitsimikizo. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty documentation included with your product or contact Red Lion customer support.

10. Thandizo

For technical assistance, product inquiries, or warranty support, please contact Red Lion customer service. You can also visit the official Red Lion webtsamba lothandizira zowonjezera ndi FAQs.

  • Mkango Wofiira Webtsamba: Visit the Red Lion Store on Amazon
  • Othandizira ukadaulo: Refer to your product packaging or the Red Lion webwebusayiti kuti mudziwe zambiri zaposachedwa.

Zolemba Zofananira - RL-WC50TA

Preview Red Lion RLWA Series Sewage Pumps Owner's Manual
Official owner's manual for Red Lion RLWA Series sewage pumps, including models RL50WA and RL75WA. Provides detailed information on installation, operation, safety guidelines, maintenance, troubleshooting, and warranty.
Preview Buku Lothandiza Pothana ndi Mavuto a Pumpu ya Red Lion: Mayankho a Mapampu a Jet, Submersible, ndi Transfer
Buku lothandizira kuthetsa mavuto a mapampu amadzi a Red Lion, kuphatikizapo Mapampu a Shallow Well Jet (monga, RJS-50-PREM), Mapampu a Convertible Jet (monga, RJC-50), Mapampu a Submersible Well a 4" (monga, RL12G10-3W2V), Mapampu a Submersible Utility & Sump, Mapampu a RL-S Cast Iron Surface Effluent, Mapampu a RL-50 Transfer, ndi Mapampu a RLSP/RLHE Sprinkler. Pezani mayankho a mavuto omwe amapezeka nthawi zambiri monga kulephera kwa injini, mavuto a priming, kuthamanga pang'ono, ndi zina zambiri.
Preview Buku la Omwe Ali ndi Pumpu Yopopera ya Red Lion RL-SPRK Series - Kukhazikitsa, Kugwiritsa Ntchito, ndi Kukonza
Bukuli limapereka malangizo athunthu a Red Lion RL-SPRK Series Sprinkler Pumps, kuphatikizapo kuyika, voltagMakonzedwe a e, ntchito, kukonza, kuthetsa mavuto, ndi zida zina. Yopangidwira makina ochapira udzu ndi udzu okhala m'nyumba ndi m'mabizinesi.
Preview Red Lion RL-MP25A Utility Pump Owner's Manual and Specifications
Comprehensive owner's manual for the Red Lion RL-MP25A Utility Pump, detailing specifications, safety instructions, installation, operation, maintenance, and troubleshooting. Includes flow rate charts and technical data.
Preview Red Lion 4-Inch Deep Well Submersible Pump Owner's Manual & Installation Guide
Comprehensive guide for Red Lion 4-inch deep well submersible pumps (RL-series and RS-series), covering specifications, safety, installation, maintenance, and troubleshooting for rural water supply. Includes model details, electrical requirements, and operational advice.
Preview Red Lion CUB5 Miniature Electronic 8-Digit Dual Counter ndi Rate Indicator
Mafotokozedwe atsatanetsatane, chitsogozo chokhazikitsa, ndi buku la mapulogalamu a Red Lion CUB5 miniature electronic counter dual indicator ndi rate indicator. Zinthu zake zikuphatikizapo LCD kapena LED backlighting yomwe ingasankhidwe, ma relay ndi ma serial communication modules osankhidwa, ndi NEMA 4X/IP65 sealing.