Mkango Wofiira 97101001

Red Lion RL-SPRK100 Sprinkler Pump User Manual

Chitsanzo: 97101001

1. Zamalonda Zathaview

The Red Lion RL-SPRK100 is a 1 HP sprinkler pump designed for residential and light commercial lawn and turf sprinkling systems. It features a rugged cast iron casing and a high-efficiency thermoplastic impeller and diffuser. This pump is engineered for reliable performance and ease of use.

Red Lion RL-SPRK100 Sprinkler Pump

Image 1.1: The Red Lion RL-SPRK100 Sprinkler Pump, showcasing its red cast iron housing.

Zofunika Kwambiri:

  • Zomangamanga Zolimba: Features a rugged cast iron pump housing and a glass-filled thermoplastic impeller, suitable for various water sources including well water and lake water.
  • Awiri Voltage Motor: Operates on either 115 Volts or 230 Volts. The pump is factory-set to 230 Volts but can be easily reconfigured to 115 Volts. It is crucial to match the pump's voltage setting to the power source voltage ntchito yoyenera.
  • Kutha Kudzipangira: Requires only a one-time initial prime. No additional priming is necessary after the initial fill, simplifying setup.
  • Kuchita Kwapamwamba: Delivers up to 63 Gallons Per Minute (GPM) at 10 PSI and 38 GPM at 30 PSI. Capable of supporting up to 12 sprinkler heads with 1/2-inch fittings or 6 sprinkler heads with 3/4-inch fittings per zone.
  • Malumikizidwe Okhazikika: Equipped with a 2-inch Female NPT threaded intake and a 1.5-inch Female NPT threaded discharge.
Red Lion RL-SPRK100 Sprinkler Pump Features

Image 1.2: Diagram highlighting key features of the pump, including the 2-inch FNPT intake, 1-1/2-inch FNPT discharge, cast iron casing, capacitor start, and thermally protected motor.

2. Kukhazikitsa ndi Kuyika

Proper installation is essential for the safe and efficient operation of your Red Lion RL-SPRK100 Sprinkler Pump. Refer to the complete installation manual included with your pump for detailed instructions and safety warnings.

Vol. 2.1 Voltagndi Kusintha

The pump motor is factory-set to 230 Volts. If your power supply is 115 Volts, you must adjust the motor's voltage setting before operation. Failure to match the pump's voltage to the source voltage will prevent the pump from performing to specifications and may cause damage.

Red Lion RL-SPRK100 Dual Voltage Motor Setting

Image 2.1: Instructions for setting the dual voltage motor. The pump is factory preset to 230V. To switch to 115V, insert a flat screwdriver into the black voltage change indicator and twist counter-clockwise.

2.2 Kutulutsa Pampu

The RL-SPRK100 is a self-priming pump, meaning it only requires an initial prime. After the initial fill, no additional priming is typically required. Follow these general steps for initial priming:

  1. Onetsetsani kuti maulalo onse a mapaipi ndi otetezeka komanso osatha.
  2. Remove the priming plug (usually located on top of the pump casing).
  3. Fill the pump casing completely with water until it overflows.
  4. Replace and tighten the priming plug.
  5. Open any discharge valves to allow air to escape the system.
  6. Start the pump. It should begin pumping water within a few minutes. If not, turn off the pump, re-prime, and check for air leaks in the suction line.
Red Lion RL-SPRK100 Self-Priming Feature

Image 2.2: The Red Lion Sprinkler Pump positioned in a lawn setting, illustrating its self-priming capability up to 25 feet after the initial prime.

3. Malangizo Ogwiritsira Ntchito

Once properly installed and primed, the Red Lion RL-SPRK100 Sprinkler Pump is ready for operation. Ensure all connections are tight and there are no obstructions in the intake or discharge lines.

3.1 Kuyambitsa Pampu

Activate the power supply to the pump. The pump will begin to draw water and build pressure. Monitor the system for any unusual noises or leaks during initial startup.

Red Lion RL-SPRK100 Sprinkler Pump in operation

Image 3.1: The Red Lion Sprinkler Pump operating in a residential setting, drawing water from a well, lake, pond, or ditch for irrigation.

3.2 Performance Guidelines

The pump is designed to deliver consistent water flow and pressure for various sprinkler system configurations. Refer to the performance chart below for expected output based on dynamic head and flow rate.

Red Lion Sprinkler Pump Performance Chart

Image 3.2: Performance curve chart for Red Lion Centrifugal Sprinkler Pumps, including the RL-SPRK100, showing Total Dynamic Head (ft) versus Capacity (US gpm).

3.3 Kutseka Pampu

To turn off the pump, deactivate the power supply. If the pump will be inactive for an extended period or during freezing temperatures, follow the maintenance guidelines for winterization.

4. Kusamalira

Regular maintenance ensures the longevity and optimal performance of your Red Lion RL-SPRK100 Sprinkler Pump.

4.1 Kuwunika pafupipafupi

  • Inspect the pump and plumbing for leaks, especially at connections.
  • Check for unusual noises or vibrations during operation, which may indicate a problem.
  • Ensure the pump's ventilation openings are clear of debris to prevent overheating.

4.2 Kusintha kwanyengo

In regions subject to freezing temperatures, it is crucial to properly winterize the pump to prevent damage:

  1. Lumikizani mphamvu ku mpope.
  2. Drain all water from the pump casing pochotsa pulagi yotulutsira madzi.
  3. Disconnect the intake and discharge pipes and drain them thoroughly.
  4. Store the pump in a dry, frost-free location if possible. If not, ensure all water is completely removed and consider using RV antifreeze in the pump casing if recommended by a professional.

5. Mavuto

This section provides general guidance for common issues. For complex problems, consult a qualified technician or contact Red Lion customer support.

5.1 Pump Does Not Start

  • Palibe Mphamvu: Check circuit breaker or fuse. Ensure power cord is securely plugged in.
  • Vol. Yolakwikatage Kukhazikitsa: Verify the pump's voltage setting matches the power supply (115V or 230V).
  • Kuchuluka kwa Magalimoto: Allow the motor to cool down if the thermal overload protector has tripped. Check for obstructions in the impeller.

5.2 Pump Runs But Delivers No Water or Low Pressure

  • Kutayika kwa Prime: Re-prime the pump as described in Section 2.2. Check for air leaks in the suction line or loose connections.
  • Clogged Intake/Impeller: Inspect the intake screen and impeller for debris.
  • Low Water Source: Ensure the water source level is adequate for the pump's suction lift capabilities.
  • Discharge Obstruction: Check for closed valves or blockages in the discharge piping or sprinkler heads.

5.3 Excessive Noise or Vibration

  • Mpweya mu Dongosolo: Ensure the pump is fully primed and there are no air leaks.
  • Kuyika momasuka: Check that the pump is securely mounted to a stable surface.
  • Foreign Object: Turn off power and inspect the impeller for any foreign objects.

6. Zofotokozera

Detailed technical specifications for the Red Lion RL-SPRK100 Sprinkler Pump.

Red Lion RL-SPRK100 Sprinkler Pump Dimensions

Image 6.1: Technical drawing illustrating the dimensions of the SPRK Series Sprinkler Pumps, including height (A), length (B), and width (C).

KufotokozeraMtengo
MtunduMkango Wofiira
Nambala ya Model97101001
Mphamvu za akavalo1 hp
Voltage115/230 volts
Wattage4848 watts
Maximum Flow Rate63 magaloni pa mphindi (GPM)
Maximum Pressure45 PSI
Maximum Kukweza Kutalika25 mapazi
Intake Thread Size2-inch Female NPT
Discharge Thread Size1.5-inch Female NPT
ZakuthupiCast Iron, Thermoplastic
Makulidwe azinthu (L x W x H)21.85" x 11.42" x 10.2"
Kulemera kwa chinthu53 mapaundi
Gwero la MphamvuCorded Electric
Kuphatikiza ZidaPump with thermoplastic impeller
UPC010121124868, 010121001398

7. Chitsimikizo ndi Thandizo

7.1 Chitsimikizo cha Wopanga

The Red Lion RL-SPRK100 Sprinkler Pump is covered by a 2-year wopanga chitsimikizo. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty information provided with your product packaging.

7.2 Thandizo laukadaulo

For technical assistance, troubleshooting guidance, or questions regarding your Red Lion product, please contact our support team:

  • Foni Yothandizira Zaukadaulo: 1-888-885-9254

Our staff are available to assist with troubleshooting or installation assistance.

Zolemba Zofananira - 97101001

Preview Buku la Omwe Ali ndi Pumpu Yopopera ya Red Lion RL-SPRK Series - Kukhazikitsa, Kugwiritsa Ntchito, ndi Kukonza
Bukuli limapereka malangizo athunthu a Red Lion RL-SPRK Series Sprinkler Pumps, kuphatikizapo kuyika, voltagMakonzedwe a e, ntchito, kukonza, kuthetsa mavuto, ndi zida zina. Yopangidwira makina ochapira udzu ndi udzu okhala m'nyumba ndi m'mabizinesi.
Preview Buku Lothandiza Pothana ndi Mavuto a Pumpu ya Red Lion: Mayankho a Mapampu a Jet, Submersible, ndi Transfer
Buku lothandizira kuthetsa mavuto a mapampu amadzi a Red Lion, kuphatikizapo Mapampu a Shallow Well Jet (monga, RJS-50-PREM), Mapampu a Convertible Jet (monga, RJC-50), Mapampu a Submersible Well a 4" (monga, RL12G10-3W2V), Mapampu a Submersible Utility & Sump, Mapampu a RL-S Cast Iron Surface Effluent, Mapampu a RL-50 Transfer, ndi Mapampu a RLSP/RLHE Sprinkler. Pezani mayankho a mavuto omwe amapezeka nthawi zambiri monga kulephera kwa injini, mavuto a priming, kuthamanga pang'ono, ndi zina zambiri.
Preview Red Lion RLHE-300 Cast Iron Industrial Sprinkler Pump Owner's Manual
Comprehensive owner's manual for the Red Lion RLHE-300 industrial sprinkler pump, covering installation, operation, maintenance, and troubleshooting. Features include heavy-duty iron casing, high-efficiency impeller, and automatic thermal protector.
Preview Red Lion CUB5 Miniature Electronic 8-Digit Dual Counter ndi Rate Indicator
Mafotokozedwe atsatanetsatane, chitsogozo chokhazikitsa, ndi buku la mapulogalamu a Red Lion CUB5 miniature electronic counter dual indicator ndi rate indicator. Zinthu zake zikuphatikizapo LCD kapena LED backlighting yomwe ingasankhidwe, ma relay ndi ma serial communication modules osankhidwa, ndi NEMA 4X/IP65 sealing.
Preview Pumpu Yothandizira Yothira ndi Kukonza ya Red Lion RJSE-75SS - Buku Lothandizira Kugwiritsa Ntchito ndi Kukonza
Buku lothandizira la Red Lion RJSE-75SS Sprinkler Utility Pump, lomwe limafotokoza machenjezo okhudza chitetezo, njira zodzitetezera zamagetsi, kugwiritsa ntchito, kuyika, kugwiritsa ntchito, kukonza, ndi kuthetsa mavuto. Lili ndi zithunzi zambiri komanso zambiri zokhudzana ndi chitsimikizo.
Preview Red Lion RL-MP25A Utility Pump Owner's Manual and Specifications
Comprehensive owner's manual for the Red Lion RL-MP25A Utility Pump, detailing specifications, safety instructions, installation, operation, maintenance, and troubleshooting. Includes flow rate charts and technical data.