AMETEK T-600 Series

AMETEK T-600 Series Hydraulic Hand Pump Instruction Manual

Model: T-600 Series (T-620, T-620H, T-620H-CPF)

Mtundu: AMETEK

1. Mawu Oyamba

The AMETEK T-600 Series Hydraulic Hand Pump is a lightweight, portable device designed for high-pressure applications. It features precise pressure control through a fine adjustment function and a vent valve for quick pressure release. This series is compatible with petroleum-based lubricants or hydraulic fluids, making it suitable for various industrial and calibration tasks.

Zofunika kwambiri ndi izi:

  • High pressure range: 0 to 5000 psi
  • Easy to use and finely tuned controls
  • Two outlet ends for versatile connections
  • Large reservoir for hydraulic fluid
  • Air clearing/venting via CPF fitting
  • T-620H-CPF model includes CPF hose and fittings
AMETEK T-600 Series Hydraulic Hand Pump, front view

Figure 1: AMETEK T-600 Series Hydraulic Hand Pump

2. Zambiri Zachitetezo

Please read and understand all safety instructions before operating the AMETEK T-600 Series Hydraulic Hand Pump. Failure to follow these instructions may result in injury or damage to the equipment.

  • Always wear appropriate personal protective equipment (PPE), such as safety glasses and gloves, when operating the pump.
  • Onetsetsani kuti maulumikizidwe onse ndi otetezeka komanso opanda madzi musanayambe kugwiritsa ntchito mphamvu.
  • Do not exceed the maximum pressure rating of the pump or the device being tested.
  • Use only recommended petroleum-based lubricants or hydraulic fluids. Mixing incompatible fluids can cause damage.
  • Keep hands and other body parts clear of moving parts and high-pressure streams.
  • Release pressure slowly and carefully using the vent valve.
  • Do not modify the pump in any way. Use only genuine AMETEK replacement parts.
  • Store the pump in a clean, dry environment away from extreme temperatures.

3. Zida Zopangira

The AMETEK T-600 Series Hydraulic Hand Pump consists of several key components:

Tsatanetsatane view of the AMETEK T-600 Series Hydraulic Hand Pump, showing controls and reservoir

Figure 2: Key Components of the Hydraulic Hand Pump

  1. Posungira: Transparent cylinder for holding hydraulic fluid.
  2. Pampu Handle: Ergonomic grip for manual pressure generation.
  3. Fine Adjustment Knob: For precise control and adjustment of pressure.
  4. Vent Valve: Used to release pressure quickly and safely.
  5. Outlet Ports: Two connection points for attaching hoses to the device under test.
  6. CPF Fitting (on T-620H-CPF model): For air clearing and venting.

4. Malangizo Kukhazikitsa

Follow these steps to set up your hydraulic hand pump:

  1. Yang'anani Pampu: Before each use, visually inspect the pump for any signs of damage, leaks, or loose connections.
  2. Dzazani Posungira: Ensure the reservoir is filled with the appropriate petroleum-based hydraulic fluid. Do not overfill.
  3. Gwirizanitsani Hoses: Attach the necessary high-pressure hoses to the pump's outlet ports and to the device you intend to test or calibrate. Ensure all connections are tight and sealed to prevent leaks.
  4. Air Clearing (if necessary): If using the T-620H-CPF model, utilize the CPF fitting for air clearing/venting to ensure accurate pressure readings and smooth operation. Consult the specific instructions for your CPF fitting if provided separately.
  5. Kuyika: Place the pump on a stable, level surface or hold it securely during operation.

5. Malangizo Ogwiritsira Ntchito

Operating the AMETEK T-600 Series Hydraulic Hand Pump involves generating and controlling hydraulic pressure:

  1. Close the Vent Valve: Before generating pressure, ensure the vent valve is fully closed.
  2. Generate Pressure: Pump the handle repeatedly to build hydraulic pressure. Monitor the pressure gauge on your connected device or an external gauge.
  3. Kusintha Kwabwino: Use the fine adjustment knob to precisely increase or decrease the pressure to the desired level. Turn clockwise to increase pressure, counter-clockwise to decrease slightly.
  4. Sungani Kupanikizika: Once the desired pressure is reached, stop pumping. The pump is designed to hold pressure stably.
  5. Kutulutsa Pressure: To release pressure, slowly open the vent valve. The vent valve is designed to cut off and release pressure quickly and proactively when opened.
  6. Kugwirizana kwa Madzi: This pump is designed for use with petroleum-based lubricants or hydraulic fluids. Do not use water or other incompatible fluids.

6. Kusamalira

Regular maintenance ensures the longevity and reliable performance of your hydraulic hand pump:

  • Kuwunika kwa Fluid Level: Periodically check the hydraulic fluid level in the reservoir. Refill as needed with the recommended fluid.
  • Fluid Replacement: Replace the hydraulic fluid annually or as recommended by fluid manufacturer, especially if it appears discolored or contaminated.
  • Kuyeretsa: Keep the exterior of the pump clean and free from dirt, dust, and debris. Use a soft, damp nsalu yoyeretsera.
  • Kuyang'ana Chisindikizo: Regularly inspect all seals and connections for signs of wear or leakage. Replace worn seals promptly.
  • Posungira: When not in use, store the pump in a clean, dry, and temperature-controlled environment. Ensure the pressure is fully released before storage.

7. Mavuto

Nazi zina zomwe zimachitika nthawi zambiri komanso mayankho ake:

VutoChifukwa ChothekaYankho
Pump not building pressureLow fluid level, air in the system, open vent valve, faulty seals.Check fluid level and refill. Bleed air from the system (if applicable). Ensure vent valve is closed. Inspect and replace seals if damaged.
Kupanikizika kumatsika mofulumiraLeaking connections, faulty check valve, worn seals.Tighten all connections. Inspect and replace seals. Contact support if check valve is suspected.
Kutayikira kwamadziZolumikizira zotayirira, mphete za O-rings kapena zomatira zowonongeka.Check and tighten all fittings. Replace any damaged O-rings or seals.
Difficulty with fine adjustmentContaminated fluid, worn adjustment mechanism.Replace hydraulic fluid. If issue persists, contact support.

8. Zofotokozera

Technical specifications for the AMETEK T-600 Series Hydraulic Hand Pump:

MbaliTsatanetsatane
Dzina la BrandAMETEKI
Njira YoyikiraWodzisunga
Chemical yokhudzidwa kwambiriPalibe
T-620 Pressure Range0 mpaka 200 bar / 0 mpaka 3000 psi
T-620H Pressure Range0 mpaka 350 bar / 0 mpaka 5000 psi
T-620H-CPF Pressure Range0 mpaka 350 bar / 0 mpaka 5000 psi
Malo OchokeraUnited States
Thandizo lokhazikikaODM

9. Malangizo Ogwiritsa Ntchito

This section provides helpful tips based on common user experiences and questions:

  • Always ensure the system you are connecting to is rated for the pressure you intend to generate.
  • When connecting hoses, hand-tighten first, then use a wrench for a final snug fit to prevent leaks without overtightening.
  • For very precise adjustments, make small turns of the fine adjustment knob and allow the system to stabilize.
  • If the pump feels stiff or difficult to operate, check the fluid level and consider replacing the hydraulic fluid.

10. Chitsimikizo ndi Thandizo

Chitsimikizo

The AMETEK T-600 Series Hydraulic Hand Pump comes with a 12 miyezi chitsimikizo kuyambira tsiku logula. Chitsimikizo ichi chimakwirira zolakwika muzinthu ndi kapangidwe kake pansi pakugwiritsa ntchito bwino. Chonde sungani umboni wanu wogula kuti mupereke chitsimikizo.

Othandizira ukadaulo

For technical assistance, troubleshooting, or warranty inquiries, please contact our support team:

  • Wopanga: AMETEKI
  • Wogulitsa: Shenzhen-Mepco-Technology Co., Ltd
  • Thandizo la WhatsApp: +8619313162195
  • Chonde khalani okonzeka ndi mtundu wa malonda anu ndi tsiku logulira mukalumikizana ndi othandizira.

Zolemba Zofananira - Zithunzi za T-600

Preview AMETEK T-600 Series Hydraulic Hand Pump Operation Manual
Bukuli limapereka zambiri za mapampu amanja a AMETEK T-600 Series hydraulic hand, kuphatikizapo T-620, T-620H, ndi T-620H-CPF. Zimakwirira mankhwalaview, mawonekedwe, mafotokozedwe, malangizo a chitetezo, njira zogwirira ntchito zopangira ndi kugwiritsa ntchito kupanikizika, zojambula zogwirizanitsa za JOFRA ndi zizindikiro za Crystal, kuthetsa mavuto, kukonza, zotsalira, ndi chidziwitso cha chitsimikizo.
Preview P014 Hydraulic Jack Pump Operation Manual
Buku la ntchito la AMETEK P014 Hydraulic Jack Pump, kufotokoza mawonekedwe ake, malangizo achitetezo, njira zogwirira ntchito, zojambula zolumikizirana, mawonekedwe ake, ndi kuthetsa mavuto.
Preview WT Series Digital Test Gauge Operation Manual
Bukuli limapereka malangizo atsatanetsatane ogwiritsira ntchito, mafotokozedwe, ndi chitsogozo chazovuta za AMETEK WT Series Digital Test Gauge.
Preview AMETEK nVision Reference Recorder: Buku Lothandizira Kupanikizika ndi Kudula Deta
Dziwani zambiri za AMETEK nVision Reference Recorder, chida chosunthika chothandizira kukakamiza, kutentha, vol.tage, ndi miyeso yamakono. Bukuli limalongosola momwe ntchito zake zimagwirira ntchito, mawonedwe azithunzi ndi manambala, mawonekedwe odula mitengo, komanso mawonekedwe olimba amakampani.
Preview AMETEK ESD Simulators: Upangiri Woyambira Mwamsanga ndi Malangizo Otetezeka
Chikalatachi chimapereka chiwongolero choyambira mwachangu komanso malangizo ofunikira achitetezo a AMETEK ESD Simulators, ophatikiza mitundu esd NX30, esd NX30.1, Dito, NSG 435, NSG 437, NSG 438, ndi NSG 438A. Imafotokoza za chitetezo, njira zogwirira ntchito, njira zoyeserera, kukonza, ndi kutaya.
Preview Buku la AMETEK Jofra CTC Series Compact Temperature Calibrator
Buku lathunthu la AMETEK Jofra CTC compact kutentha calibrators (CTC-155, CTC-350, CTC-652, CTC-660, CTC-1205 A/C), kuphimba khwekhwe, ntchito, malangizo chitetezo, ndi kukonza.