AmScope B120C

AmScope B120C Series Binocular Compound Microscope User Manual

Model: B120C | Brand: AmScope

1. Zamalonda Zathaview

The AmScope B120C compound binocular microscope is designed for both student and professional use, offering a wide magnification range from 40X to 2500X. It features a comfortable Siedentopf head, precise 3D mechanical stage, and bright LED illumination, making it suitable for detailed examination of various specimens.

AmScope B120C Binocular Compound Microscope with eyepieces and oil

Figure 1.1: The AmScope B120C Binocular Compound Microscope, showcasing its main components including the binocular head, objective lenses, mechanical stage, and included eyepieces and immersion oil.

  • Magnification Excellence: Offers a broad magnification range from 40X to 2500X for detailed specimen examination.
  • Advanced LED Illumination: Provides bright, daylight-balanced illumination with a specialized fly-eye lens for optimal viewndi.
  • Mapangidwe a Ergonomic: Features a 360-degree rotatable Siedentopf head with adjustable interpupillary distance for comfortable and flexible viewndi.
  • Precision Stage Control: A 3D mechanical stage and coaxial coarse and fine focus knobs allow for smooth and precise adjustments.

2. Zomwe zili mu Bokosi

Mukatsegula bokosi, chonde onetsetsani kuti pali zinthu zonse zotsatirazi:

  • AmScope B120C microscope with double-layer mechanical stage
  • (4) DIN Standard Objectives: 4x, 10x, 40xS, and 100xS (oil)
  • 10x widefield eyepieces, one pair
  • 25x widefield eyepieces, one pair
  • Color filter, blue
  • Immersion oil, one bottle
  • Chophimba chafumbi
  • Malangizo (bukuli)

3. Kukonzekera Guide

Follow these steps to set up your AmScope B120C microscope:

  1. Kutulutsa: Chotsani mosamala zinthu zonse zomwe zili mu phukusi. Sungani phukusi loyambirira kuti musunge kapena kunyamula mtsogolo.
  2. Kuyika: Ikani maikulosikopu pamalo okhazikika, osalala kutali ndi kuwala kwa dzuwa mwachindunji, kutentha kwambiri, kapena kugwedezeka.
  3. Ikani Ma Eyepieces: Insert the desired pair of eyepieces (10x or 25x) into the ocular tubes of the Siedentopf head.
  4. Lumikizani Mphamvu: Plug the power cord into the microscope's power input and then into a standard electrical outlet (100 to 240VAC 50/60Hz).
  5. Chophimba Fumbi: Keep the dust cover on the microscope when not in use to protect it from dust and debris.

Video 3.1: Kuthaview of the AmScope B120C Siedentopf Binocular Compound Microscope, demonstrating its features and basic setup. This video is provided by United Scope LLC, the manufacturer.

4. Malangizo Ogwiritsira Ntchito

4.1. Magnification Adjustment

The microscope offers a wide range of magnification by combining different eyepieces and objective lenses. The total magnification is calculated by multiplying the eyepiece magnification by the objective lens magnification.

  • Zowonera: Use either the 10x widefield or 25x widefield eyepieces.
  • Magalasi a cholinga: Rotate the forward-facing nosepiece to select from 4x, 10x, 40xS (spring-loaded), and 100xS (spring-loaded, oil immersion) DIN achromatic objectives.
  • The 40xS and 100xS objectives are spring-loaded to prevent damage to slides when focusing.
Close-up of AmScope B120C objective lenses and WF25X eyepieces

Figure 4.1: Detail of the objective lenses (4x, 10x, 40x, 100x) and the additional WF25X eyepieces, illustrating the microscope's magnification capabilities.

4.2. Kuwongolera Kuwala

The microscope uses lower (diascopic) Brightfield LED illumination to transmit light through the specimen.

  • Gwero la Kuwala kwa LED: Turn on the LED illumination using the power switch. Adjust the brightness using the rheostat control knob.
  • Abbe Condenser (1.25 NA): Adjust the condenser to control the distance of the light from the stage.
  • Iris Diaphragm: Use the iris diaphragm lever to optimize the amount of light illuminating the specimen, enhancing contrast and resolution.
AmScope B120C microscope showing LED transmitted illumination

Figure 4.2: The LED transmitted illumination system, providing bright and cool light for viewing specimens from below the stage.

4.3. Kuika maganizo

Achieve clear focus using the coaxial coarse and fine focus knobs:

  • Coarse Focus Knob: Use for large adjustments to bring the specimen into approximate focus, especially with lower magnification objectives.
  • Fine Focus Knob: Use for small, precise adjustments to achieve sharp focus, particularly with higher magnification objectives.
Close-up of AmScope B120C mechanical stage and focus knobs

Chithunzi 4.3: Makinatage and coaxial coarse and fine focus knobs, designed for smooth and accurate specimen positioning and focusing.

4.4. Zimango Stage Ntchito

The double-layer mechanical stage allows for precise movement of the slide.

  • Slide Holder: Secure the microscope slide using the slide clips on the mechanical stage.
  • X-Y Axis Control: Use the X-Y axis knobs located below the stage to move the slide horizontally and vertically, allowing you to scan the specimen area.

4.5. Siedentopf Head Adjustment

The Siedentopf binocular head is designed for comfortable viewkugawana ndi kugawana.

  • Inter-pupillary Adjustment: Adjust the distance between the two ocular tubes (53 to 77mm) to match your eye spacing for comfortable viewndi.
  • Kusintha kwa Dioptric: Use the diopter ring on one of the ocular tubes to compensate for differences in eye strength between your left and right eyes.
  • Kasinthasintha: The head can rotate 360 degrees, which is useful for sharing the view with others without moving the entire microscope.
AmScope B120C microscope with 360 degree rotatable binocular head

Figure 4.4: The 360-degree rotatable Siedentopf binocular head, angled at 30 degrees for ergonomic viewing and easy sharing.

5. Kusamalira

Proper maintenance ensures the longevity and optimal performance of your microscope:

  • Kuyeretsa Magalasi: Gwiritsani ntchito mapepala oyeretsera magalasi apadera ndi yankho lokha poyeretsa magalasi ndi magalasi oyeretsera maso. Pewani kukhudza malo owoneka ndi manja opanda kanthu.
  • Thupi Loyeretsa: Pukutani thupi la maikulosikopu ndi chofewa, damp nsalu. Pewani kugwiritsa ntchito mankhwala owopsa kapena zotsukira.
  • Chitetezo cha fumbi: Always use the provided dust cover when the microscope is not in use to prevent dust accumulation.
  • Posungira: Store the microscope in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Mafuta Omiza: After using the 100x oil immersion objective, clean the oil from the lens immediately using lens paper and cleaning solution.

6. Mavuto

Chigawochi chikuwonetsa zovuta zomwe mungakumane nazo:

VutoChifukwa ChothekaYankho
Palibe kuunikiraPower cord not connected, power switch off, bulb failure, fuse blown.Check power connection. Turn on power switch. Replace LED bulb (contact support if needed). Check/replace fuse.
Chithunzi chili chopanda mawonekedwe kapena chosawoneka bwinoIncorrect focus adjustment, dirty lenses, objective not fully clicked into place.Adjust coarse and fine focus. Clean objective and eyepiece lenses. Rotate objective until it clicks into position.
Dark spots in the field of viewDust on eyepiece, objective, or condenser.Clean eyepieces and objectives. Check for dust on the condenser and stage.
Double image when using binocular headInter-pupillary distance not correctly adjusted.Adjust the inter-pupillary distance until a single circular field of view zimawonedwa.

7. Zofotokozera

MbaliTsatanetsatane
MutuCompound binocular, Siedentopf, 30-degree inclination, 360-degree rotatable
Zojambula m'masoWF 10x, WF 25x
Zolinga4X, 10x, 40xS, 100xS (oil) DIN achromatic
Makulitsidwe Range40X-2500X
StageDouble-layer Mechanical Stage yokhala ndi magawo a 1mm
Kuyikira KwambiriCoaxial coarse komanso mikwingwirima yolunjika
Kusintha kwa KuwunikiraTransmitted (bottom) Brightfield
Condenser1.25 NA Abbe with iris diaphragm
Gwero LowalaLED
Mphamvu100 to 240VAC 50/60Hz
Miyeso Yazinthu18 x 12 x 10 mainchesi
Kulemera kwa chinthu3.25 mapaundi
ZakuthupiEnamel-coated cast-steel body

8. Chitsimikizo ndi Thandizo

AmScope products are manufactured by United Scope LLC, a company founded in 1996 and headquartered in Irvine, CA. For technical support, warranty information, or service inquiries, please contact AmScope customer service directly. Refer to the official AmScope webtsamba lawebusayiti kuti mudziwe zambiri zamakono zokhudzana ndi kulumikizana ndi kampani komanso mfundo za chitsimikizo.

Zothandizira pa intaneti:

  • Official AmScope Webtsamba: www.amscope.com
  • Product Support Page: Check the AmScope website for specific support pages related to the B120C model.

© 2024 AmScope. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.